Stable release of AxxSolder v3.2.0
Changes from previous release (AxxSolder v3.1.0):
-
Implement an outlier detection and filter for the thermocouple readings.
Sometimes false readings of the thermocouple were happening resulting in the PID trying to respond to these false readings causing a temperature swing. Now there is a filter detecting these false readings and filter them out.
-
Add a user setting for showing temperatures in Fahrenheit (default is Celsius).
-
Make hardware version function to start incrementation on version 3. 43dc170
-
Update fw version format and show hw version in settings menu e2fc366
NEW Hardware version
There is also a new hardware, AxxSolder 3.1!
The RC filters on buttons and encoder are improved and designed in a better way. This do not effect the usage of AxxSodler as this was solved in software for the previous releases.
It is mostly to have a "correctly designed" version published.
There were also some minor layout improvements and clean-ups done.