[code sync] Merge code from sonic-net/sonic-buildimage:202205 to 202205 #96

Merged
merged 6 commits into from
Sep 2, 2023
23 changes: 11 additions & 12 deletions device/nokia/x86_64-nokia_ixr7250e_36x400g-r0/platform_reboot
Original file line number Diff line number Diff line change
@@ -1,31 +1,30 @@
#!/bin/bash

update_reboot_cause_for_supervisor_reboot()
update_reboot_cause()
{
DEVICE_MGR_REBOOT_FILE=/tmp/device_mgr_reboot
REBOOT_CAUSE_FILE=/host/reboot-cause/reboot-cause.txt
TMP_REBOOT_CAUSE_FILE=/tmp/tmp-reboot-cause.txt
if [ -f $DEVICE_MGR_REBOOT_FILE ]; then
if [ -f $REBOOT_CAUSE_FILE ]; then
t1=`sudo grep "User: ," $REBOOT_CAUSE_FILE`
if [ ! -z "$t1" ]; then
echo $t1 | sed 's/reboot/reboot from Supervisor/g' | sed 's/User: /User: admin/g' > $TMP_REBOOT_CAUSE_FILE
cp $TMP_REBOOT_CAUSE_FILE $REBOOT_CAUSE_FILE
fi
DEVICE_REBOOT_CAUSE_FILE=/etc/opt/srlinux/reboot-cause.txt
if [ -e $DEVICE_MGR_REBOOT_FILE ]; then
if [ -e $DEVICE_REBOOT_CAUSE_FILE ]; then
cp -f $DEVICE_REBOOT_CAUSE_FILE $REBOOT_CAUSE_FILE
fi
rm -f $DEVICE_MGR_REBOOT_FILE
else
touch /etc/opt/srlinux/devmgr_reboot_cause.done
rm -f $DEVICE_REBOOT_CAUSE_FILE &> /dev/null
fi
sync
}

# update the reboot_cuase file when reboot is trigger by device-mgr
update_reboot_cause_for_supervisor_reboot
update_reboot_cause

systemctl stop nokia-watchdog.service
sleep 2
echo "w" > /dev/watchdog
kick_date=`date -u`
echo "last watchdog kick $kick_date" > /var/log/nokia-watchdog-last.log
rm -f /sys/firmware/efi/efivars/dump-*
touch /etc/opt/srlinux/devmgr_reboot_cause.done
rm -f /etc/opt/srlinux/reboot-cause.txt
sync
exec /sbin/reboot $@
101 changes: 101 additions & 0 deletions files/scripts/swss.sh
Original file line number Diff line number Diff line change
Expand Up @@ -107,6 +107,106 @@ function clean_up_tables()
end" 0
}

# This function cleans up the chassis db table entries created ONLY by this asic
# This is used to do the clean up operation when the line card / asic reboots
# When the asic/lc is RE-booting, the chassis db server is supposed to be running
# in the supervisor. So the clean up is done when only the chassis db connectable.
# Otherwise no need to do the clean up since both the supervisor and line card may be
# rebooting (the whole chassis scenario)
# The clean up operation is required to delete only those entries created by
# the asic that is rebooted. Entries from the following tables are deleted in the order
# given below
# (1) SYSTEM_NEIGH
# (2) SYSTEM_INTERFACE
# (3) SYSTEM_LAG_MEMBER_TABLE
# (4) SYSTEM_LAG_TABLE
# (5) The corresponding LAG IDs of the entries from SYSTEM_LAG_TABLE
# SYSTEM_LAG_ID_TABLE and SYSTEM_LAG_ID_SET are adjusted appropriately
function clean_up_chassis_db_tables()
{
if [[ !($($SONIC_DB_CLI CHASSIS_APP_DB PING | grep -c True) -gt 0) ]]; then
return
fi

lc=`$SONIC_DB_CLI CONFIG_DB hget 'DEVICE_METADATA|localhost' 'hostname'`
asic=`$SONIC_DB_CLI CONFIG_DB hget 'DEVICE_METADATA|localhost' 'asic_name'`
switch_type=`$SONIC_DB_CLI CONFIG_DB hget 'DEVICE_METADATA|localhost' 'switch_type'`

# Run clean up only in swss running for voq switches
if is_chassis_supervisor || [[ $switch_type != 'voq' ]]; then
return
fi

# First, delete SYSTEM_NEIGH entries
$SONIC_DB_CLI CHASSIS_APP_DB EVAL "
local host = string.gsub(ARGV[1], '%-', '%%-')
local dev = ARGV[2]
local ps = 'SYSTEM_NEIGH*|' .. host .. '|' .. dev
local keylist = redis.call('KEYS', 'SYSTEM_NEIGH*')
for j,key in ipairs(keylist) do
if string.match(key, ps) ~= nil then
redis.call('DEL', key)
end
end
return " 0 $lc $asic

# Wait for some time before deleting system interface so that the system interface's "object in use"
# is cleared in both orchangent and in syncd. Without this delay, the orchagent clears the refcount
# but the syncd (meta) still has no-zero refcount. Because of this, orchagent gets "object still in use"
# error and aborts.

sleep 30

# Next, delete SYSTEM_INTERFACE entries
$SONIC_DB_CLI CHASSIS_APP_DB EVAL "
local host = string.gsub(ARGV[1], '%-', '%%-')
local dev = ARGV[2]
local ps = 'SYSTEM_INTERFACE*|' .. host .. '|' .. dev
local keylist = redis.call('KEYS', 'SYSTEM_INTERFACE*')
for j,key in ipairs(keylist) do
if string.match(key, ps) ~= nil then
redis.call('DEL', key)
end
end
return " 0 $lc $asic

# Next, delete SYSTEM_LAG_MEMBER_TABLE entries
$SONIC_DB_CLI CHASSIS_APP_DB EVAL "
local host = string.gsub(ARGV[1], '%-', '%%-')
local dev = ARGV[2]
local ps = 'SYSTEM_LAG_MEMBER_TABLE*|' .. host .. '|' .. dev
local keylist = redis.call('KEYS', 'SYSTEM_LAG_MEMBER_TABLE*')
for j,key in ipairs(keylist) do
if string.match(key, ps) ~= nil then
redis.call('DEL', key)
end
end
return " 0 $lc $asic

# Wait for some time before deleting system lag so that the all the memebers of the
# system lag will be cleared.

sleep 15

# Finally, delete SYSTEM_LAG_TABLE entries and deallot LAG IDs
$SONIC_DB_CLI CHASSIS_APP_DB EVAL "
local host = string.gsub(ARGV[1], '%-', '%%-')
local dev = ARGV[2]
local ps = 'SYSTEM_LAG_TABLE*|' .. '(' .. host .. '|' .. dev ..'.*' .. ')'
local keylist = redis.call('KEYS', 'SYSTEM_LAG_TABLE*')
for j,key in ipairs(keylist) do
local lagname = string.match(key, ps)
if lagname ~= nil then
redis.call('DEL', key)
local lagid = redis.call('HGET', 'SYSTEM_LAG_ID_TABLE', lagname)
redis.call('SREM', 'SYSTEM_LAG_ID_SET', lagid)
redis.call('HDEL', 'SYSTEM_LAG_ID_TABLE', lagname)
end
end
return " 0 $lc $asic

}

start_peer_and_dependent_services() {
check_warm_boot

Expand Down Expand Up @@ -177,6 +277,7 @@ start() {
$SONIC_DB_CLI RESTAPI_DB FLUSHDB
clean_up_tables STATE_DB "'PORT_TABLE*', 'MGMT_PORT_TABLE*', 'VLAN_TABLE*', 'VLAN_MEMBER_TABLE*', 'LAG_TABLE*', 'LAG_MEMBER_TABLE*', 'INTERFACE_TABLE*', 'MIRROR_SESSION*', 'VRF_TABLE*', 'FDB_TABLE*', 'FG_ROUTE_TABLE*', 'BUFFER_POOL*', 'BUFFER_PROFILE*', 'MUX_CABLE_TABLE*', 'ADVERTISE_NETWORK_TABLE*', 'VXLAN_TUNNEL_TABLE*', 'MACSEC_PORT_TABLE*', 'MACSEC_INGRESS_SA_TABLE*', 'MACSEC_EGRESS_SA_TABLE*', 'MACSEC_INGRESS_SC_TABLE*', 'MACSEC_EGRESS_SC_TABLE*', 'VNET_ROUTE*', 'VNET_MONITOR_TABLE*', 'BFD_SESSION_TABLE*'"
$SONIC_DB_CLI APPL_STATE_DB FLUSHDB
clean_up_chassis_db_tables
rm -rf /tmp/cache
fi

Expand Down
2 changes: 1 addition & 1 deletion installer/x86_64/install.sh
Original file line number Diff line number Diff line change
Expand Up @@ -668,7 +668,7 @@ CPUVENDOR="$(cat /proc/cpuinfo | grep -m 1 vendor_id | awk '{print $3}')"
echo "Switch CPU vendor is: $CPUVENDOR"
if echo "$CPUVENDOR" | grep -i 'Intel' >/dev/null 2>&1; then
echo "Switch CPU cstates are: disabled"
CSTATES="intel_idle.max_cstate=0"
CSTATES="processor.max_cstate=1 intel_idle.max_cstate=0"
else
CSTATES=""
fi
Expand Down
2 changes: 1 addition & 1 deletion src/sonic-swss