For models with the Rec Tec Grills Wi-Pellet WiFi controller (standard on RT-340, RT-590, RT-700, and available as upgrade to RT-300 & RT-680).
Pretty version of Rec Tec JSON schema:
[
{
"mode": "rw",
"code": "Power",
"name": "Switch",
"property": {
"type": "bool"
},
"iconname": "icon-dp_power",
"id": 1,
"type": "obj",
"desc": ""
},
{
"mode": "rw",
"code": "Set_temp",
"name": "Set Temperature",
"property": {
"unit": "",
"min": 0,
"max": 65535,
"scale": 0,
"step": 5,
"type": "value"
},
"id": 102,
"type": "obj",
"desc": ""
},
{
"mode": "ro",
"code": "Actual_temp",
"name": "Actual Temperature",
"property": {
"unit": "",
"min": 0,
"max": 65535,
"scale": 0,
"step": 1,
"type": "value"
},
"id": 103,
"type": "obj",
"desc": ""
},
{
"mode": "rw",
"code": "Min_feedrate",
"name": "Minimum Feeding Amount",
"property": {
"unit": "",
"min": 0,
"max": 255,
"scale": 0,
"step": 1,
"type": "value"
},
"id": 104,
"type": "obj",
"desc": ""
},
{
"mode": "ro",
"code": "Food_temp1",
"name": "Food Temperature 1",
"property": {
"unit": "",
"min": 0,
"max": 65535,
"scale": 0,
"step": 1,
"type": "value"
},
"id": 105,
"type": "obj",
"desc": ""
},
{
"mode": "ro",
"code": "Food_temp2",
"name": "Food Temperature 2",
"property": {
"unit": "",
"min": 0,
"max": 65535,
"scale": 0,
"step": 1,
"type": "value"
},
"id": 106,
"type": "obj",
"desc": ""
},
{
"mode": "rw",
"code": "Temp_adjust",
"name": "Temperature Calibration",
"property": {
"unit": "",
"min": -128,
"max": 127,
"scale": 0,
"step": 1,
"type": "value"
},
"id": 107,
"type": "obj",
"desc": ""
},
{
"mode": "rw",
"code": "Temp_unit",
"name": "Temperature Unit Switching",
"property": {
"type": "bool"
},
"id": 108,
"type": "obj",
"desc": ""
},
{
"mode": "ro",
"code": "ER1",
"name": "ER1 Alarm",
"property": {
"type": "bool"
},
"id": 109,
"type": "obj",
"desc": ""
},
{
"mode": "ro",
"code": "ER2",
"name": "ER2 Alarm",
"property": {
"type": "bool"
},
"id": 110,
"type": "obj",
"desc": ""
},
{
"mode": "ro",
"code": "ER3",
"name": "ER3 Alarm",
"property": {
"type": "bool"
},
"id": 111,
"type": "obj",
"desc": ""
}
]