You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Running 2.1.1, using to test a set of 15 DMX outputs that the cable runs were labeled haphazardly with repeated wire numbers and device numbers. Set up 16 universes of sACN using the mulit-universe generator starting at universe 2 and going up to universe 17. Set each universe to sinewave fade a single address starting at 2/1, 3/2, 4/3, up to 17/16.
At the 10th universe added it stops sinewave fading a single address and goes to all addresses below the end address column, meaning I see adressses 1-10 fading, and not 10 only, and for each added universe in my setup, they fade 1-End Address.
I will download 2.1.2 and see if it repeats there.
The text was updated successfully, but these errors were encountered:
Downloaded 2.1.2, and confirmed the issue remains. Universes 1-9 set to single addresses (sequential to match universe) work as expected. starting with universe 10, it goes to 1-end address all fading simultaneously.
Running 2.1.1, using to test a set of 15 DMX outputs that the cable runs were labeled haphazardly with repeated wire numbers and device numbers. Set up 16 universes of sACN using the mulit-universe generator starting at universe 2 and going up to universe 17. Set each universe to sinewave fade a single address starting at 2/1, 3/2, 4/3, up to 17/16.
At the 10th universe added it stops sinewave fading a single address and goes to all addresses below the end address column, meaning I see adressses 1-10 fading, and not 10 only, and for each added universe in my setup, they fade 1-End Address.
I will download 2.1.2 and see if it repeats there.
The text was updated successfully, but these errors were encountered: