Notifications
You must be signed in to change notification settings - Fork 91
ZigBee Devices
This page provides an overview per manufacturer of the ZCL configuration of the ZigBee Devices connected to my Hue bridge, as reported by deCONZ. It lists the endpoints and clusters per device type. Server clusters are in boldface.
I joined my RaspBee to the ZigBee network created by my Hue bridge and, after that, these devices where discovered automatically by deCONZ.
TODO:
- Try and touch link a second Hue bridge to a Hue bridge;
- Try and touch link a Hue bridge to a Hue dimmer switch;
Here's the configuration for a second-generation Hue bridge (firmware version 01038390):
Endpoint | Profile | Cluster | Name |
---|---|---|---|
F2 | ZGP | 0061 unknown | |
0021 | ZigBee Green Power Proxy | ||
40 | ZLL | Control Bridge | |
1000 | ZLL Commissioning | ||
0019 | OTAU | ||
1000 | ZLL Commissioning | ||
0004 | Groups | ||
0005 | Scenes | ||
0000 | Basic | ||
0300 | Color Control | ||
0003 | Identify | ||
0008 | Level Control | ||
0006 | On/Off | ||
41 | ZHA | Combined Interface | |
000F | Binary Input (Basic) | ||
0406 | Occupancy Sensing | ||
0402 | Temperature Measurement | ||
0405 | Humidify Measurement | ||
FC00 | Vendor Specific | ||
0400 | Illuminance Measurement |
Notes:
- A first-generation Hue bridge (firmware version 01036659) looks the same, except for the order of the endpoints: 40, 41, F2 instead of F2, 40, 41.
- The ZGG endpoint matches the Hue lights and, I suspect, the Hue tap.
- The ZLL endpoint matches the Hue lights, except for the ZLL Commissioning server cluster. As mentioned in the Hue developer forum, it was possible to (touch?) link two Hue bridges, but the procedure seems to be lost.
- So the Hue bridge does talk ZHA?!
- The Hue motion sensor has corresponding server clusters for the ZHA 0406, 0402, and 0040 clients.
- The Hue dimmer switch has a corresponding server clusters for the ZHA 000F and FC00 clients. FC00 is used for
buttonevent
. - When connecting a previously standalone dimmer switch to a Hue bridge (using the Hue app), the bridge can "inherit" the lights from the dimmer switch. Since the Hue dimmer switch lacks a ZLL Commissioning cluster, I suspect the 000F cluster might be used for this.
- I cannot find a matching server cluster for the ZHA 0405 client. Apparently Philips considered a ZigBee version of the CLIPHumidity sensor? However, there doesn't seem to be a ZigBee version of the CLIPOpenClose sensor?
Here's the configuration for a Hue Extended Color Light:
Endpoint | Profile | Cluster | Name |
---|---|---|---|
0B | ZLL | Extended Color Light | |
0000 | Basic | ||
0003 | Identify | ||
0004 | Groups | ||
0005 | Scenes | ||
0006 | On/Off | ||
0008 | Level Control | ||
0300 | Color Control | ||
1000 | ZLL Commissioning | ||
0019 | OTAU | ||
F2 | ZGP | 0061 unknown | |
0021 | ZigBee Green Power Sink | ||
0021 | ZigBee Green Power Proxy |
Notes:
- A Hue Color Light and a Hue Color Temperature Lights have the same configuration. So does a Hue Dimmable Light, except that, of course, it misses the Color Control cluster.
- On the Hue bridge, the
uniqueid
attribute for a Hue light is00:17:88:01:0x:xx:xx:xx-0b
, matching the ZLL endpoint.
Here's the configuration for a Hue motion sensor:
Endpoint | Profile | Cluster | Name |
---|---|---|---|
02 | ZHA | Occupancy Sensor | |
0000 | Basic | ||
0001 | Power Configuration | ||
0003 | Identify | ||
0406 | Occupancy Sensing | ||
0400 | Illuminance Measurement | ||
0402 | Temperature Measurement | ||
0019 | OTAU | ||
01 | ZLL | On/Off Sensor | |
0000 | Basic | ||
0000 | Basic | ||
0003 | Identify | ||
0004 | Groups | ||
0006 | On/Off | ||
0008 | Level Control | ||
0300 | Color Control | ||
0005 | Scenes |
Notes:
- So the Hue motion sensor does talk ZHA?!
- On the Hue bridge, a Hue motion sensor is exposed as three sensor resources: a ZLLPresence with a
uniqueid
of00:17:88:01:02:xx:xx:xx-02-0406
, a ZLLLightLevel with00:17:88:01:02:xx:xx:xx-02-0400
, and a ZLLTemperature with00:17:88:01:02:xx:xx:xx-02-0402
. These match the ZHA endpoint and cluster. - The ZLL endpoint seems to suggest a Hue motion sensor could work standalone, without a Hue bridge, like the Hue dimmer switch?!
- The Hue motion sensor uses standard ZigBee attribute reporting on the 0406, 0400, and 0402 clusters to inform the Hue bridge of changes to motion, light level, or temperature. It also supports attribute reporting on the 0001 cluster for the battery percentage.
Here's the configuration for a Hue dimmer switch (firmware 5.45.1.17846):
Endpoint | Profile | Cluster | Name |
---|---|---|---|
01 | ZLL | Non-Color-Scene Controller | |
0000 | Basic | ||
0000 | Basic | ||
0003 | Identify | ||
0004 | Groups | ||
0006 | On/Off | ||
0008 | Level Control | ||
0005 | Scenes | ||
02 | ZHA | 000C unknown | |
0000 | Basic | ||
0001 | Power Configuration | ||
0003 | Identify | ||
000F | Binary Input (Basic) | ||
FC00 | Vendor Specific | ||
0019 | OTAU |
Notes:
- The Scenes cluster is missing from two of my dimmers, which report as a Non-Color Controler device. These dimmers have a different label on the back and a different firmware version (5.45.1.16265).
- So the Hue dimmer switch does talk ZHA?!
- On the Hue bridge, a Hue dimmer switch is exposed as a ZLLSwitch sensor with a
uniqueid
of00:17:88:01:10:xx:xx:xx-02-fc00
. This matches the ZHA endpoint and the FC00 cluster. - The Hue bridge has a corresponding clients for the 000F and FC00 clusters. The FC00 cluster is used for button events. It's unknown what the 000F cluster is used for.
- The Hue dimmer switch uses standard ZigBee attribute reporting for the FC00 cluster, to send button events to the Hue bridge. In addition, it sends commands from the 0006 and 0008 clusters, to interact directly with lights.
The Hue tap doesn't show in the deCONZ gui, but the REST API reports ep
of 242
which is 0xF2
.
Endpoint | Profile | Cluster | Name |
---|---|---|---|
F2 | ZGP | ? |
Notes:
- On the Hue bridge, a Hue tap is exposed as a ZGPSwitch sensor with a
uniqueid
of00:00:00:00:00:xx:xx:xx-f2
, matching the ZGP endpoint on the Hue bridge and Hue lights.
Here's the configuration for a Lightify Home Gateway (ZigBee firmware version 1.2.0.68):
Endpoint | Profile | Cluster | Name |
---|---|---|---|
40 | ZLL | Control Bridge | |
1000 | ZLL Commissioning | ||
0019 | OTAU | ||
1000 | ZLL Commissioning | ||
0004 | Groups | ||
0005 | Scenes | ||
0000 | Basic | ||
0300 | Color Control | ||
0003 | Identify | ||
0008 | Level Control | ||
0006 | On/Off | ||
41 | ZHA | Combined Interface | |
000F | Binary Input (Basic) | ||
0406 | Occupancy Sensing | ||
0402 | Temperature Measurement | ||
0405 | Humidify Measurement | ||
FC00 | Vendor Specific | ||
0400 | Illuminance Measurement | ||
F2 | ZGP | 0061 unknown | |
0021 | ZigBee Green Power Proxy |
Notes:
- This is exactly the same configuration as for a (first-generation) Hue bridge.
Here's the configuration for an Osram E14 bulb:
Endpoint | Profile | Cluster | Name |
---|---|---|---|
03 | ZLL | Color Temperature Light | |
1000 | ZLL Commissioning | ||
0000 | Basic | ||
0003 | Identify | ||
0004 | Groups | ||
0005 | Scenes | ||
0006 | On/Off | ||
0008 | Level Control | ||
0300 | Color Control | ||
FC0F | ? Device Setup | ||
0019 | OTAU |
Notes:
- On the Hue bridge, an OSRAM light has a
uniqueid
of84:18:26:00:00:xx:xx:xx-03
, matching the ZLL endpoint. - I suspect OSRAM use the FC0F cluster for setting the power-on default. There's no corresponding client cluster in the Lightify Home Gateway, though.
- The light does support attribute reporting on the 0006, 0008, and 0C00 clusters.
Here's the configuration for an Osram plug (firmware 01020315):
Endpoint | Profile | Cluster | Name |
---|---|---|---|
03 | ZLL | On/Off Plug-In Unit | |
1000 | ZLL Commissioning | ||
0000 | Basic | ||
0003 | Identify | ||
0004 | Groups | ||
0005 | Scenes | ||
0006 | On/Off | ||
0B04 | ? Electrical Measurement | ||
0019 | OTAU |
Notes:
- On the Hue bridge, an OSRAM plug has a
uniqueid
of84:18:26:00:00:xx:xx:xx-03
, matching the ZLL endpoint. - There doesn't seem to be any Electrical Measurement feature in the OSRAM Lightly app. There's no corresponding client cluster in the Lightify Home Gateway either.
I've not been able to join the RaspBee to a network created by the innr Gateway. innr seem to use a different commissioning scheme: their lights only join a network for a short period after they're powered on.
Here's the configuration for an innr RB 162 dimmable light:
Endpoint | Profile | Cluster | Name |
---|---|---|---|
01 | ZLL | Dimmable Light | |
0000 | Basic | ||
0004 | Groups | ||
0003 | Identify | ||
0006 | On/Off | ||
0008 | Level Control | ||
0005 | Scenes | ||
02 | ZLL | 1000 unknown | |
1000 | ZLL Commissioning |
Notes:
- On the Hue bridge, an innr bulb has a
uniqueid
of00:15:8d:00:00:xx:xx:xx-01
, matching the first ZLL endpoint. - Indeed, no over-the-air update for the firmware as innr support had indicated.
Here's the configuration for an innr PL 110 or UC 110, which use the same control board:
Endpoint | Profile | Cluster | Name |
---|---|---|---|
01 | ZLL | Dimmable Light | |
0000 | Basic | ||
0004 | Groups | ||
0003 | Identify | ||
0006 | On/Off | ||
0008 | Level Control | ||
0005 | Scenes | ||
FFFF | ? | ||
0019 | OTAU | ||
0000 | Basic | ||
0004 | Groups | ||
0003 | Identify | ||
0006 | On/Off | ||
0008 | Level Control | ||
0005 | Scenes | ||
0019 | OTAU |
Notes:
- On the Hue bridge, an innr light has a
uniqueid
of00:15:8d:00:00:xx:xx:xx-01
, matching the ZLL endpoint. - Huh, support for over-the-air update for the firmware?
- Huh, no ZLL Commissioning? Maybe that's why these aren't listed under certified devices on the ZigBee alliance website?
- I've no clue about the FFFF cluster. Maybe it's the ZLL Commissioning with a wrong cluster ID? The control board can be touch linked to the Hue bridge.
- The control board seems to be configurable as a ZigBee control device as well. Physically, it does contain an unused header. Maybe innr plan to use the same board in their sensors?
Currently, the Ikea Trådfri lights are advertised as not compatible with the Hue bridge. Curious to find out why, I got myself an E27 980lm Color temperature light with a round, 5-button remote. The light and the remote work well together, out of the box.
I touchlinked the light to the Hue bridge, and it responded. As expected, the light no longer reacts to the remote. So the light joins the ZigBee network created by the Hue bridge without any problem.
As advertised, the Hue bridge doesn't find the light when searching for new lights, but it does appear in the deCONZ GUI. The deCONZ REST API picked it up as well:
{
"etag": "162cd7e2cd4b29553fbe5deea036de83",
"hascolor": true,
"manufacturer": "IKEA of Sweden",
"modelid": "TRADFRI bulb E27 WS�opal 980lm",
"name": "Light 17",
"pointsymbol": {},
"state": {
"alert": "none",
"bri": 127,
"colormode": "ct",
"ct": 300,
"effect": "none",
"hue": 0,
"on": true,
"reachable": true,
"sat": 0,
"xy": [
0.46168,
0.412215
]
},
"swversion": "1.1.1.1-5.7.2.0",
"type": "Color temperature light",
"uniqueid": "00:0b:57:ff:fe:xx:xx:xx-01"
}
Likewise, I touch linked the remote to the Hue bridge. It appears in the deCONZ GUI, so the remote also joins the Hue bridge ZigBee network without any issue. Neither the Hue bridge, nor the deCONZ REST API finds the remote.
Here's the configuration for an Ikea Trådfri E27 980lm bulb:
Endpoint | Profile | Cluster | Name |
---|---|---|---|
01 | ZHA | Color temperature light | |
0000 | Basic | ||
0003 | Identify | ||
0004 | Groups | ||
0005 | Scenes | ||
0006 | On/Off | ||
0008 | Level Control | ||
0300 | Color Control | ||
0B05 | Diagnostics | ||
1000 | ZLL commissioning | ||
0005 | Scenes | ||
0019 | OTAU | ||
0020 | Poll Control | ||
1000 | ZLL commissioning |
Notes:
- So the light provides the usual clusters, like the other vendor's lights, but on a ZHA endpoint. This is consistent with the info on the Internet. No way the Hue bridge is going to accept that.
- The light supports
ct
values from 250 (4000K) to 454 (~2200K). The box seemed to suggest that it only had three colour temperature settings, but that's a limitation of the remote. - The light supports attribute reporting for the 0006, 0008, and 0C00 clusters, but you need to write the config, before it can be read.
Here's the configuration for an Ikea Trådfri remote control:
Endpoint | Profile | Cluster | Name |
---|---|---|---|
01 | ZHA | Color scene controller | |
0000 | Basic | ||
1000 | Power Configuration | ||
0003 | Identify | ||
0009 | Alarms | ||
0B05 | Diagnostics | ||
1000 | ZLL commissioning | ||
0003 | Identify | ||
0004 | Groups | ||
0005 | Scenes | ||
0006 | On/Off | ||
0008 | Level Control | ||
0019 | OTAU | ||
1000 | ZLL commissioning |
Notes:
- As with the Trådfri light, it exposes the usual cluster, but on a ZHA endpoint.
- The remote uses commands from the 0006, 0008, and 0005 clusters. The Previous and Next buttons use non-standard Scene commands to change the colour temperature of Trådfri lights.
Unisys switches use ZigBee 3.0, so they won't pair with the Hue bridge. They work with deCONZ.
Xiaomi use ZigBee in a very non-standard way, but deCONZ does support some of these devices.
Home | FAQ | Getting Started | Reference