Notifications
You must be signed in to change notification settings - Fork 1
/
simulator.py
685 lines (637 loc) · 27.2 KB
/
simulator.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
#!/usr/bin/env python2.7
import os
from optparse import OptionParser
from conf import *
from commons import *
from infrastructure import *
from location import *
from workload import *
from datetime import datetime, timedelta
# GreenSwitch
import sys
sys.path.append('parasolsolver')
from parasolsolver import ParasolModel
from parasolsolvercommons import TimeValue
"""
Simulator
TODO list:
-
TEST list:
-
"""
class Simulator:
def __init__(self, infrafile, locationfile, workloadfile, period=SIMULATIONTIME, turnoff=True):
self.infra = Infrastructure(infrafile)
self.location = Location(locationfile)
self.workload = Workload(workloadfile)
self.period = period
# turn on/off servers
self.turnoff = turnoff
# Policy
self.greenswitch = True
# Battery management
self.batteryManagement = True
def getLogFilename(self):
filename = LOG_PATH+'/result'
# Size
filename += '-%.1f' % self.infra.it.getMaxPower()
# Solar
filename += '-%d' % self.infra.battery.capacity
# Battery
filename += '-%d' % self.infra.solar.capacity
# Period
filename += '-%s' % timeStr(self.period)
# Net metering
if self.location.netmetering > 0.0:
filename += '-net%.2f' % self.location.netmetering
# Workload
workloadname = self.workload.filename
workloadname = workloadname[workloadname.rfind('/')+1:workloadname.rfind('.')]
filename += '-%s' % workloadname
# Location
if self.location.name != None:
filename += '-%s' % self.location.name
# Cooling
if self.infra.cooling.coolingtype != None:
filename += '-cool'+self.infra.cooling.coolingtype
# Delay
if self.workload.deferrable == True:
filename += '-delay'
# Always on
if self.turnoff == False:
filename += '-on'
# GreenSwitch
if self.greenswitch == False:
filename += '-nogreenswitch'
# GreenSwitch
filename += '.log'
return filename
"""
Run simulation
"""
def run(self):
# Costs
costbrownenergy = 0.0
costbrownpower = 0.0
# Errors
errors = 0
# Peak brown
peakbrown = 0.0
peakbrownlife = 0.0
# Store start date for peak brown accounting
startdate = datetime(2013, 1, 1)
currentmonth = 1
# No previous load
prevLoad = 0.0
prevNodes = 0.0
# We start with full capacity
batlevel = 100.0 # Fully charge
prevbatlevel = 100.0 # Fully charge
battery = batlevel/100.0 * self.infra.battery.capacity # Wh
# Battery
batcharge = 0.0
batdischarge = 0.0
# Battery status
batchargingstatus = False
batdischargingstatus = True
batcyclestartlevel = 100.0
# Battery stats
batnumdischarges = 0 # How many discharges
battotaldischarge = 0.0 # Total DoD (%)
batmaxdischarge = 0.0 # Maximum DoD (%)
batlifetime = 0.0 # Lifetime (%)
# State
stateChargeBattery = False
stateNetMeter = False
# Get the number of servers available
numServers = self.infra.it.getNumServers()
# Datacenter
# Location traces
# Workload
print 'Simulation period: %s' % (timeStr(self.period))
if self.workload.deferrable:
print 'Deferrable workload'
if self.turnoff != False:
print 'Turn off nodes'
# Logging file
try:
fout = open(self.getLogFilename(), 'w')
fout.write('# Time\tBPrice\tGreen\tNetMet\tBrown\tBatChar\tBatDisc\tBatLevel\tWorload\tCooling\tExLoad\tPrLoad\n')
except Exception, e:
fout = None
print e
# Use GreenSwitch policy
solver = ParasolModel()
solver.options.optCost = 1.0
# Load
solver.options.loadDelay = self.workload.deferrable
solver.options.compression = self.workload.compression
'''
if solver.options.loadDelay:
solver.options.minSize = self.infra.it.getPower(self.workload.minimum, minimum=self.workload.minimum, turnoff=self.turnoff)
else:
solver.options.minSize = self.infra.it.getPower(0, minimum=self.workload.minimum, turnoff=self.turnoff)
'''
solver.options.minSize = self.infra.it.getPower(0, minimum=self.workload.minimum, turnoff=self.turnoff)
solver.options.maxSize = self.infra.it.getMaxPower()
# Power infrastructure costs
solver.options.netMeter = self.location.netmetering
# Building cost
solver.options.peakCostLife = self.infra.price
# Battery
solver.options.batEfficiency = self.infra.battery.efficiency
solver.options.batCap = self.infra.battery.capacity
solver.options.batDischargeMax = 0.20 # 20% DoD
# Set initial DoD based on 1 discharge per day
if self.batteryManagement:
start = 0.0
end = 70.0
# Dicotomic search
while end-start > 0.1:
mid = start+(end-start)/2.0
cycles = self.infra.battery.getBatteryCycles(mid)
lifetimeyear = (100.0/cycles) * 365
if lifetimeyear > 20.0:
end = mid
else:
start = mid
solver.options.batDischargeMax = round(mid/100.0, 2)
if solver.options.batDischargeMax > 0.75:
solver.options.batDischargeMax = 0.75
# Simulation core
# Iterate the maximum time (PERIOD) in steps (TIMESTEP)
for t in range(0, self.period/TIMESTEP):
# Collect current data
time = t*TIMESTEP
brownenergyprice = self.location.getBrownPrice(time)
temperature = self.location.getTemperature(time)
#coolingpower = self.infra.cooling.getPower(temperature)
pue = self.infra.cooling.getPUE(temperature)
# Green power
solar = self.location.getSolar(time)
solarpower = solar * self.infra.solar.capacity * self.infra.solar.efficiency
wind = self.location.getWind(time)
windpower = wind * self.infra.wind.capacity * self.infra.wind.efficiency
greenpower = round(solarpower + windpower, 1)
# Apply policy
if not self.greenswitch:
# If we don't use GreenSwitch, there is no solution
sol = None
else:
# Update GreenSwitch policy parameters
solver.options.prevLoad = prevLoad
solver.options.previousPeak = peakbrown
#solver.options.previousPeak = 0.95*peakbrown
#solver.options.previousPeak = 0.85*peakbrown
#solver.options.previousPeak = 0.0
solver.options.previousPeakLife = peakbrownlife
solver.options.peakCost = self.location.brownpowerprice[time]
# Battery
solver.options.batIniCap = battery
# Covering subset workload
reqNodes = self.workload.getLoad(time)*numServers
coveringPower = self.infra.it.getPower(reqNodes, minimum=self.workload.minimum, turnoff=self.turnoff) + prevLoad/solver.options.compression
# All the covering subset running
if coveringPower > self.infra.it.getPower(self.workload.minimum, minimum=self.workload.minimum, turnoff=self.turnoff):
coveringPower = self.infra.it.getPower(self.workload.minimum, minimum=self.workload.minimum, turnoff=self.turnoff)
# All the covering subset idle
if coveringPower < self.infra.it.getPower(0, minimum=self.workload.minimum, turnoff=self.turnoff):
coveringPower = self.infra.it.getPower(0, minimum=self.workload.minimum, turnoff=self.turnoff)
solver.options.minSizeIni = round(coveringPower, 2)
# Fill data with actual values and predictions
greenAvail = [] if self.infra.solar.capacity > 0.0 else None
brownPrice = []
puePredi = []
worklPredi = []
for predhour in range(0, solver.options.maxTime):
# Current values
if predhour == 0:
# Green available
if self.infra.solar.capacity > 0.0:
greenAvail.append(TimeValue(0, greenpower))
# Brown price
b = round(self.location.getBrownPrice(time), 5)
brownPrice.append(TimeValue(0, b))
# PUE
temperature = self.location.getTemperature(time)
pue = round(self.infra.cooling.getPUE(temperature), 4)
puePredi.append(TimeValue(0, pue))
# Workload
reqNodes = self.workload.getLoad(time)*numServers
loadPower = self.infra.it.getPower(reqNodes, minimum=self.workload.minimum, turnoff=self.turnoff)
w = round(loadPower, 4)
worklPredi.append(TimeValue(0, w))
# Predicted values
else:
predseconds = predhour*60*60
# Green availability prediction: right now is perfect knowledge
if self.infra.solar.capacity > 0.0:
g = round(self.location.getSolar(time + predseconds) * self.infra.solar.capacity * self.infra.solar.efficiency, 4)
greenAvail.append(TimeValue(predseconds, g))
# Brown price prediction
b = round(self.location.getBrownPrice(time + predseconds), 5)
brownPrice.append(TimeValue(predseconds, b))
# PUE
temperature = self.location.getTemperature(time + predseconds)
pue = round(self.infra.cooling.getPUE(temperature), 4)
puePredi.append(TimeValue(predseconds, pue))
# Actual workload
#reqNodes = self.workload.getLoad(time + predseconds)
# Workload average based on prediction
reqNodes = []
for i in range(0, int(1.0*solver.options.slotLength/TIMESTEP)):
reqNodes.append(self.workload.getLoad(time + predseconds + i*TIMESTEP)*numServers)
reqNodes = 1.0*sum(reqNodes)/len(reqNodes)
loadPower = self.infra.it.getPower(reqNodes, minimum=self.workload.minimum, turnoff=self.turnoff)
#w = round(loadPower, 1)
w = math.ceil(loadPower)
# TODO Workload prediction: w = 1000.0
worklPredi.append(TimeValue(predseconds, w))
# Generate solution
#if timeStr(time) == '272d17h15m':# or timeStr(time) == '110d22h30m':
#solver.saveModel = True
scale = 1.0 if solver.options.maxSize < 1000*1000 else 1000.0
obj, sol = solver.solve(greenAvail=greenAvail, brownPrice=brownPrice, pue=puePredi, load=worklPredi, stateChargeBattery=stateChargeBattery, stateNetMeter=stateNetMeter, scale=scale)
#solver.saveModel = False
# Initialize
brownpower = 0.0
netpower = 0.0
batcharge = 0.0
batdischarge = 0.0
# Check if we have a GreenSwitch solution
if sol == None:
if self.greenswitch:
print "No solution at", timeStr(time)
fout.write("# Solver error at %s\n" % timeStr(time))
errors += 1
# Calculate workload: Get the number of nodes required
reqNodes = self.workload.getLoad(time)*numServers
workload = self.infra.it.getPower(reqNodes, minimum=self.workload.minimum, turnoff=self.turnoff)
temperature = self.location.getTemperature(time)
#coolingPower = self.infra.cooling.getPower(temperature)
pue = self.infra.cooling.getPUE(temperature)
# Use brown
brownpower = workload*pue - greenpower
if brownpower < 0.0:
netpower = -1.0*brownpower
brownpower = 0.0
# Use batteries if we can
if brownpower > 0.0:
if solver.options.batCap > 0.0:
# Calculate the battery percentage we can discharge
batdischargeavail = (solver.options.batIniCap/solver.options.batCap) - (1.0-solver.options.batDischargeMax)
# Transform it into power (% -> Wh -> W)
batdischargeavail = batdischargeavail * solver.options.batCap * (3600.0/TIMESTEP)
# Check negative
if batdischargeavail < 0.0:
batdischargeavail = 0.0
# Brown power -> Battery discharge
batdischarge = batdischargeavail
if brownpower < batdischarge:
batdischarge = brownpower
# Update brown power
brownpower -= batdischarge
# Load
execload = workload
else:
# Load
reqNodes = self.workload.getLoad(time)*numServers
workload = self.infra.it.getPower(reqNodes, minimum=self.workload.minimum, turnoff=self.turnoff)
# Cooling
temperature = self.location.getTemperature(time)
pue = self.infra.cooling.getPUE(temperature)
# Get solution from solver
execload = sol['Load[0]']
# Calculate brown power and net metering
brownpower = sol['BattBrown[0]'] + sol['LoadBrown[0]']
netpower = sol['NetGreen[0]']
# Battery
batdischarge = sol['LoadBatt[0]']
batcharge = sol['BattBrown[0]'] + sol['BattGreen[0]']
load = sol['LoadBrown[0]'] + sol['LoadGreen[0]'] + sol['LoadBatt[0]']
# Delay load
if self.workload.deferrable:
# Delayed load = Current workload - executed load
difference = (workload - execload)*(TIMESTEP/(60.0*60.0))
if difference >= 0.0:
prevLoad += difference
else:
# Depending on the workload, we may compress the load when delaying
prevLoad += difference*self.workload.compression
if prevLoad < 0:
prevLoad = 0.0
# Fix solution to match the actual system (Parasol)
'''
# This shouldn't be needed anymore
# Sometimes the solver says to run more than the load we have there
if execload > workload+prevLoad:
print 'We are running more than what we actually have'
print execload, workload, prevLoad
surplus = execload - (workload+prevLoad)
execload -= surplus
brownpower -= surplus
if brownpower < 0.0:
batdischarge += brownpower
if batdischarge < 0.0:
if batcharge > 0.0:
batcharge += -batdischarge
else:
netpower += -batdischarge
batdischarge = 0.0
brownpower = 0.0
print execload, workload, prevLoad
'''
# If we charge, we cannot do net metering at the same time
if batcharge > 0.0 and netpower > 0.0:
'''
print 'Error: charging battery and net metering at the same time.'
print 'Time:', timeStr(time)
print 'Battery: %.1f%%' % (100.0*battery/solver.options.batCap)
print 'Battery charge: %.1fW' % batcharge
print 'Net metering: %.1fW' % netpower
'''
batcharge += netpower
netpower = 0.0
# If we are using less than what the solver gave us, adjust it
inPower = greenpower + brownpower + batdischarge
outPower = execload*pue + netpower + batcharge
if abs(inPower-outPower) > 1.0:
print timeStr(time), 'We have a disadjustment'
print ' IN: %.1fW' % (greenpower + brownpower + batdischarge)
print ' OUT: %.1fW' % (execload*pue + netpower + batcharge)
print ' Green: %.1fW' % greenpower
print ' Brown: %.1fW' % brownpower
print ' BDisc: %.1fW' % batdischarge
print ' ='
print ' NetMe: %.1fW' % netpower
print ' BChar: %.1fW' % batcharge
print ' Load: %.1fW = %.1fW*%.2f' % (execload*pue, execload, pue)
if brownpower > 0.0:
brownpower = execload*pue + netpower + batcharge - greenpower - batdischarge
if brownpower < 0.0:
brownpower = 0.0
print 'Adjust brown: %.1fW' % brownpower
if batdischarge > 0.0:
batdischarge = execload*pue + netpower + batcharge - greenpower - brownpower
if batdischarge < 0.0:
batdischarge = 0.0
print 'Adjust battery discharge: %.1fW' % batdischarge
# Surplus green
if batdischarge == 0.0 and brownpower == 0.0:
# If we are charging, charge more
if batcharge > 0.0 or stateChargeBattery:
batcharge = greenpower - execload*pue
print 'Adjust battery charge: %.1fW' % batcharge
# Otherwise, just net meter
else:
netpower = greenpower - execload*pue
print 'Adjust net metering: %.1fW' % netpower
print 'Solution at', timeStr(time), 'was:'
print ' Green ', greenAvail[0]
print ' Workload ', worklPredi[0]
print ' PUE ', puePredi[0]
print ' Brown ', brownPrice[0]
print ' Load ', sol['Load[0]']
print ' LoadBrown ', sol['LoadBrown[0]']
print ' LoadBatt ', sol['LoadBatt[0]']
print ' LoadGreen ', sol['LoadGreen[0]']
print ' PrevLoad ', prevLoad
print ' BattBrown ', sol['BattBrown[0]']
print ' BattGreen ', sol['BattGreen[0]']
print ' CapBattery', sol['CapBattery[0]']
print ' NetGreen ', sol['NetGreen[0]']
print ' PeakBrown ', sol['PeakBrown']
'''
if timeStr(time) == '35d3h': #timeStr(time) == '204d20h15m':# or time == 1080900:
try:
print 'Solution at', timeStr(time), 'was:'
print ' Load ', sol['Load[0]']
print ' LoadBrown ', sol['LoadBrown[0]']
print ' LoadBatt ', sol['LoadBatt[0]']
print ' LoadGreen ', sol['LoadGreen[0]']
print ' BattBrown ', sol['BattBrown[0]']
print ' BattGreen ', sol['BattGreen[0]']
print ' CapBattery', sol['CapBattery[0]']
except:
pass
print 'Input at', timeStr(time), 'was:'
if greenAvail!=None:
print ' Green ', greenAvail[0]
print ' Workload ', worklPredi[0]
print ' PUE ', puePredi[0]
print ' Brown ', brownPrice[0]
print 'Brown'
for tv in brownPrice:
print 'TimeValue(%d, %f), ' % (tv.t, tv.v)
if greenAvail!=None:
print 'Green'
for tv in greenAvail:
print 'TimeValue(%d, %f), ' % (tv.t, tv.v)
print 'PUE'
for tv in puePredi:
print 'TimeValue(%d, %f), ' % (tv.t, tv.v)
print 'Workload'
for tv in worklPredi:
print 'TimeValue(%d, %f), ' % (tv.t, tv.v)
print stateChargeBattery
print stateNetMeter
print 'Options'
print ' slotLength ', solver.options.slotLength
print ' timeLimit ', solver.options.timeLimit
print ' maxTime ', solver.options.maxTime
print ' optCost ', solver.options.optCost
print ' loadDelay ', solver.options.loadDelay
print ' compression ', solver.options.compression
print solver.options.minSizeIni
print solver.options.minSize
print solver.options.maxSize
print ' netMeter ', solver.options.netMeter
print ' batEfficiency ', solver.options.batEfficiency
print ' batIniCap ', solver.options.batIniCap
print ' batCap ', solver.options.batCap
print ' batDischargeMax ', solver.options.batDischargeMax
print ' batDischargeProtection ', solver.options.batDischargeProtection
print ' batChargeRate ', solver.options.batChargeRate
print ' prevLoad ', solver.options.prevLoad
print ' previousPeak ', solver.options.previousPeak
print ' previousPeakLife', solver.options.previousPeakLife
print ' peakCost ', solver.options.peakCost
print ' peakCostLife ', solver.options.peakCostLife
print 'Result:'
print ' LoadBrown', sol['LoadBrown[0]']
print ' BattBrown', sol['BattBrown[0]']
'''
# Charge/discharge battery
#aux = (100.0*battery/self.infra.battery.capacity)
#aux = battery
battery += ((self.infra.battery.efficiency * batcharge) - batdischarge) * (TIMESTEP/3600.0)
#print '%.2f = %.2f + %.2fx%.2f - %.2f %.2f' % (battery/1000000.0, aux/1000000.0, self.infra.battery.efficiency, batcharge/1000000.0, batdischarge/1000000.0, (TIMESTEP/3600.0))
#print '%10s %.2f%% => %.2f%% [%.1f%%] %4.2fMW +%.1fMW -%.1fMW' % (timeStr(time), aux, 100.0*battery/self.infra.battery.capacity, 100.0*(1-solver.options.batDischargeMax), peakbrown/1000000.0, batcharge/1000000.0, batdischarge/1000000.0)
if battery > self.infra.battery.capacity:
battery = self.infra.battery.capacity
if battery < solver.options.batCap*solver.options.batDischargeProtection:
print timeStr(time), 'Error: battery was discharged further than the protection limit: %.1fMWh < %.1fMWh < %.1fMWh' % (battery/(1000.0*1000.0), solver.options.batCap*solver.options.batDischargeProtection/(1000.0*1000.0), solver.options.batCap/(1000.0*1000.0))
battery = solver.options.batCap*solver.options.batDischargeProtection
# Account battery lifetime
if self.infra.battery.capacity > 0.0:
# Start charging cycle
batlevel = 100.0 * battery / self.infra.battery.capacity
if batcharge > 0.0 and not batchargingstatus:
batchargingstatus = True
batdischargingstatus = False
# Account previous discharge
batlevel0 = batcyclestartlevel
batlevel1 = prevbatlevel
# A discharge of more than 0.1%
if batlevel0 - batlevel1 > 0.1:
batnumdischarges += 1
battotaldischarge += batlevel0 - batlevel1
if batlevel0 - batlevel1 > batmaxdischarge:
batmaxdischarge = batlevel0 - batlevel1
# Account lifetime
dod = batlevel0 - batlevel1
cycles = self.infra.battery.getBatteryCycles(dod)
if cycles > 0.0:
batlifetime += 100.0/cycles
#print '%s: %.2f%% -> %.2f%%: %.3f%%' % (timeStr(time), batlevel0, batlevel1, batlifetime)
# Start discharging cycle
elif batdischarge > 0.0 and not batdischargingstatus:
batchargingstatus = False
batdischargingstatus = True
batcyclestartlevel = batlevel
# Store previous value
prevbatlevel = batlevel
# Change DoD based on battery lifetime projections (every 5 days)
if self.batteryManagement and time>0 and time%parseTime('5d') == 0:
# Calculate battery lifetime by this time
projbatlifetime = 100.0*time/float(self.infra.battery.lifetimemax*365*24*60*60)
if batlifetime < projbatlifetime:
solver.options.batDischargeMax += 0.05 # Increase 5%
elif batlifetime > projbatlifetime:
solver.options.batDischargeMax -= 0.05 # Decrease 5%
# Adjust margins 0 < x < 80% => 20% always
if solver.options.batDischargeMax > 0.75:
solver.options.batDischargeMax = 0.75
if solver.options.batDischargeMax < 0.00:
solver.options.batDischargeMax = 0.00
# Update state
if batcharge > 0.0:
stateChargeBattery = True
else:
stateChargeBattery = False
if netpower > 0.0:
stateNetMeter = True
else:
stateNetMeter = False
# Check peak brown power
if brownpower > peakbrown:
peakbrown = brownpower
if brownpower > peakbrownlife:
peakbrownlife = brownpower
# Account operational costs
# Grid electricity
costbrownenergy += (TIMESTEP/SECONDS_HOUR) * brownpower/1000.0 * brownenergyprice # (seconds -> hours) * kW * $/kWh
# Net metering
costbrownenergy -= (TIMESTEP/SECONDS_HOUR) * netpower/1000.0 * brownenergyprice * self.location.netmetering # (seconds -> hours) * kW * $/kWh * %
# Peak power accounting every month
if (startdate + timedelta(seconds=time)).month != currentmonth:
costbrownpower += self.location.brownpowerprice[time-parseTime('1d')] * peakbrown/1000.0
#print 'Month %d: %.2fMW (%.2fMW)' % (currentmonth, peakbrown/1000000.0, peakbrownlife/1000000.0)
fout.write('# Peak brown power month %d: $%.2f (%.2fW)\n' % (currentmonth, self.location.brownpowerprice[time-parseTime('1d')] * peakbrown/1000.0, peakbrown))
# Flush file
fout.flush()
os.fsync(fout.fileno())
# Reset accounting
peakbrown = 0.0
currentmonth = (startdate + timedelta(seconds=time)).month
# Logging
if fout != None:
fout.write('%d\t%.2f\t%.2f\t%.2f\t%.2f\t%.2f\t%.2f\t%.2f\t%.2f\t%.2f\t%.2f\t%.2f\n' % (time, brownenergyprice, greenpower, netpower, brownpower, batcharge, batdischarge, battery, workload, execload*(pue-1.0), execload, prevLoad))
# Account for the last month
costbrownpower += self.location.brownpowerprice[time-parseTime('1d')] * peakbrown/1000.0
# Datacenter cost
costdatacenter = 0.0
if self.infra.price != None:
costdatacenter += peakbrownlife * self.infra.price
# Infrastructure cost (lifetime)
costinfrastructure = costdatacenter
costinfrastructure += self.infra.solar.capacity * self.infra.solar.price # Solar
costinfrastructure += self.infra.wind.capacity * self.infra.wind.price # Wind
costinfrastructure += self.infra.battery.capacity * self.infra.battery.price * TOTAL_YEARS/self.infra.battery.lifetimemax # Battery
# Infrastructure cost (first)
costinfrastructurefirst = costdatacenter
costinfrastructurefirst += self.infra.solar.capacity * self.infra.solar.price # Solar
costinfrastructurefirst += self.infra.wind.capacity * self.infra.wind.price # Wind
costinfrastructurefirst += self.infra.battery.capacity * self.infra.battery.price # Battery
# Summary
print '$%.2f + $%.2f + $%.2f = $%.2f' % (costbrownenergy, costbrownpower, costinfrastructure, costbrownenergy+costbrownpower+costinfrastructure)
# Log file
if fout != None:
fout.write('# Summary:\n')
fout.write('# Brown energy: $%.2f\n' % (costbrownenergy))
fout.write('# Peak brown power: $%.2f\n' % (costbrownpower))
fout.write('# Peak brown power life: $%.2f (%.2fW)\n' % (costdatacenter, peakbrownlife))
fout.write('# Infrastructure: $%.2f ($%.2f)\n' % (costinfrastructure, costinfrastructurefirst))
fout.write('# Battery number discharges: %d\n' % (batnumdischarges))
fout.write('# Battery max discharge: %.2f%%\n' % (batmaxdischarge))
fout.write('# Battery total discharge: %.2f%%\n' % (battotaldischarge))
fout.write('# Battery lifetime: %.2f%%\n' % (batlifetime))
fout.write('# Total: $%.2f\n' % (costbrownenergy+costbrownpower+costinfrastructure))
fout.write('# Solver errors %d\n' % errors)
fout.close()
"""
It reads the options and runs the simulation.
"""
if __name__ == "__main__":
parser = OptionParser(usage="usage: %prog [options] filename", version="%prog 1.0")
# Data files
parser.add_option('-w', '--workload', dest='workload', help='specify the workload file', default=DATA_PATH+'workload/variable.workload')
parser.add_option('-l', '--location', dest='location', help='specify the location file', default=DATA_PATH+'locations/parasol.location')
parser.add_option('-i', '--infra', dest='infra', help='specify the infrastructure file', default=DATA_PATH+'parasol.infra')
# Period
parser.add_option('-p', '--period', dest='period', help='specify the infrastructure file', default='1y')
# Infrastructure options
parser.add_option('-s', '--solar', dest='solar', type="string", help='specify the infrastructure has solar', default=None)
parser.add_option('-b', '--battery', dest='battery', type="string", help='specify the infrastructure has batteries', default=None)
parser.add_option('--nosolar', dest='nosolar', action="store_true", help='specify the infrastructure has no solar')
parser.add_option('--nobattery', dest='nobattery', action="store_true", help='specify the infrastructure has no batteries')
parser.add_option('-c', '--cooling', dest='cooling', help='specify the cooling infrastructure file', default=None)
#parser.add_option('--offset', dest='offset', type="string", help='specify offset', default=None)
parser.add_option('--solardata', dest='solardata', type="string", help='specify offset', default=None)
# GreenSwitch
parser.add_option('-g', '--nogswitch',dest='greenswitch',action="store_false", help='specify if we use greenswitch')
# Load
parser.add_option('-d', '--delay', dest='delay', action="store_true", help='specify if we can delay the load')
parser.add_option('-o', '--alwayson', dest='alwayson', action="store_true", help='specify if the system is always on')
# Location
parser.add_option('--net', dest='netmeter', type="float", help='specify the net metering revenue', default=None)
(options, args) = parser.parse_args()
# Initialize simulator
simulator = Simulator(options.infra, options.location, options.workload, parseTime(options.period), turnoff=not options.alwayson)
# Change options
if options.nobattery == True:
simulator.infra.battery.capacity = 0.0
if options.nosolar == True:
simulator.infra.solar.capacity = 0.0
if options.battery != None:
simulator.infra.battery.capacity = parseEnergy(options.battery)
if options.solar != None:
simulator.infra.solar.capacity = parsePower(options.solar)
if options.netmeter != None:
simulator.location.netmetering = options.netmeter
if options.cooling != None:
simulator.infra.cooling.read(options.cooling)
# Solar (e.g. validation)
if options.solardata != None:
simulator.location.solar = simulator.location.readValues(options.solardata)
simulator.location.solarcapacity = 3200.0
simulator.location.solarefficiency = 0.97
simulator.location.solaroffset = 0.0
# Policy
if options.delay == True:
simulator.workload.deferrable = True
if options.greenswitch == False:
simulator.greenswitch = False
simulator.infra.printSummary()
# Run simulation
simulator.run()