GroundFloorUPS (American Power Conversion/Back-UPS NS 1500M2/957.e3 .D) battery.charge (Battery charge (percent of full)) : 100 battery.charge.low (Remaining battery level when UPS switches to LB (percent)) : 10 battery.charge.warning (Battery level when UPS switches to Warning state (percent)) : 50 battery.date (Battery change date) : 2001/09/25 battery.mfr.date (Battery manufacturing date) : 2020/01/29 battery.runtime (Battery runtime (seconds)) : 3381 battery.runtime.low (Remaining battery runtime when UPS switches to LB (seconds)) : 120 battery.type (Battery chemistry) : PbAc battery.voltage (Battery voltage (V)) : 27.4 battery.voltage.nominal (Nominal battery voltage (V)) : 24.0 device.mfr (Description unavailable) : American Power Conversion device.model (Description unavailable) : Back-UPS NS 1500M2 device.serial (Description unavailable) : 3B2005X24000 device.type (Description unavailable) : ups driver.name (Driver name) : usbhid-ups driver.parameter.pollfreq (Description unavailable) : 30 driver.parameter.pollinterval (Description unavailable) : 2 driver.parameter.port (Description unavailable) : auto driver.parameter.productid (Description unavailable) : 0002 driver.parameter.serial (Description unavailable) : 3B2005X24000 driver.parameter.synchronous (Description unavailable) : no driver.parameter.vendorid (Description unavailable) : 051d driver.version (Driver version - NUT release) : 2.7.4 driver.version.data (Description unavailable) : APC HID 0.96 driver.version.internal (Internal driver version) : 0.41 input.sensitivity (Input power sensitivity) : low input.transfer.high (High voltage transfer point (V)) : 142 input.transfer.low (Low voltage transfer point (V)) : 78 input.voltage (Input voltage (V)) : 120.0 input.voltage.nominal (Nominal input voltage (V)) : 120 ups.beeper.status (UPS beeper status) : disabled ups.delay.shutdown (Interval to wait after shutdown with delay command (seconds)) : 20 ups.firmware (UPS firmware) : 957.e3 .D ups.firmware.aux (Auxiliary device firmware) : e3 ups.load (Load on UPS (percent of full)) : 11 ups.mfr (UPS manufacturer) : American Power Conversion ups.mfr.date (UPS manufacturing date) : 2020/01/29 ups.model (UPS model) : Back-UPS NS 1500M2 ups.productid (Product ID for USB devices) : 0002 ups.realpower.nominal (UPS real power rating (W)) : 900 ups.serial (UPS serial number) : 3B2005X24000 ups.status (UPS status) : OL ups.test.result (Results of last self test) : No test initiated ups.timer.reboot (Time before the load will be rebooted (seconds)) : 0 ups.timer.shutdown (Time before the load will be shutdown (seconds)) : -1 ups.vendorid (Vendor ID for USB devices) : 051d