Log files are always the same file size and length. #191

Open
4 tasks done
Gon-97 opened this issue Oct 9, 2024 · 1 comment
Open
4 tasks done

Log files are always the same file size and length. #191

Gon-97 opened this issue Oct 9, 2024 · 1 comment
Assignees
Labels
bug Something isn't working

Comments

@Gon-97
Copy link

Gon-97 commented Oct 9, 2024

Please make sure to fill out this form completely, and attach your program logs (set to Debug setting). You can delete this line.

  • Searched to see if this issue exists
  • Completed below form
  • Attached debug log file
  • Copy output in File -> UPS Variable

**WinNUT Version: 2.3.8988.30525
**Windows OS Version: 10

Describe the bug
The log files are always the same file size and only last from 12am to about 2:35am and then there are no more log entries until a new file is created the next day.

To Reproduce
Steps to reproduce the behavior:
Look at log files.

Expected behavior
I expect the log files to contain entries from the entire day.

Screenshots
image
image
image

Additional context
UPS Variable output:
ups (American Power Conversion/Back-UPS BGM1500B/31316S12-31320S10)
battery.charge (Battery charge (percent of full)) : 93
battery.charge.low (Remaining battery level when UPS switches to LB (percent)) : 30
battery.mfr.date (Battery manufacturing date) : 1980/01/01
battery.runtime (Battery runtime (seconds)) : 760
battery.runtime.low (Remaining battery runtime when UPS switches to LB (seconds)) : 120
battery.type (Battery chemistry) : PbAc
battery.voltage (Battery voltage (V)) : 27.3
battery.voltage.nominal (Nominal battery voltage (V)) : 24.0
device.mfr (Description unavailable) : American Power Conversion
device.model (Description unavailable) : Back-UPS BGM1500B
device.serial (Description unavailable) : 0B2118P00686
device.type (Description unavailable) : ups
driver.debug (Current debug verbosity level of the driver program) : 0
driver.flag.allow_killpower (Safety flip-switch to allow the driver daemon to send UPS shutdown command (accessible via driver.killpower)) : 0
driver.name (Driver name) : usbhid-ups
driver.parameter.lowbatt (Description unavailable) : 30
driver.parameter.pollfreq (Description unavailable) : 30
driver.parameter.pollinterval (Description unavailable) : 2
driver.parameter.port (Description unavailable) : auto
driver.parameter.synchronous (Description unavailable) : auto
driver.state (Description unavailable) : quiet
driver.version (Driver version - NUT release) : 2.8.2.1
driver.version.data (Description unavailable) : APC HID 0.100
driver.version.internal (Internal driver version) : 0.57
driver.version.usb (USB library version) : libusb-1.0.26 (API: 0x1000108)
input.sensitivity (Input power sensitivity) : medium
input.transfer.high (High voltage transfer point (V)) : 147
input.transfer.low (Low voltage transfer point (V)) : 88
input.transfer.reason (Reason for last transfer to battery) : input voltage out of range
input.voltage (Input voltage (V)) : 122.0
input.voltage.nominal (Nominal input voltage (V)) : 120
ups.beeper.status (UPS beeper status) : enabled
ups.delay.shutdown (Interval to wait after shutdown with delay command (seconds)) : 20
ups.firmware (UPS firmware) : 31316S12-31320S10
ups.load (Load on UPS (percent of full)) : 38
ups.mfr (UPS manufacturer) : American Power Conversion
ups.mfr.date (UPS manufacturing date) : 2021/04/22
ups.model (UPS model) : Back-UPS BGM1500B
ups.productid (Product ID for USB devices) : 0002
ups.realpower.nominal (UPS real power rating (W)) : 900
ups.serial (UPS serial number) : 0B2118P00686
ups.status (UPS status) : OL CHRG LB
ups.test.result (Results of last self test) : Done and passed
ups.timer.reboot (Time before the load will be rebooted (seconds)) : 0
ups.timer.shutdown (Time before the load will be shutdown (seconds)) : -1
ups.vendorid (Vendor ID for USB devices) : 051d

WinNUT-Client-2024-10-07.log

@Gon-97 Gon-97 added the bug Something isn't working label Oct 9, 2024
@gbakeman
Copy link
Contributor

Looks like some kind of buffer is being filled up. I'll try to look into this later, but in the meantime, I'd recommend you set the WinNUT logging level to anything other than Debug unless you're trying to troubleshoot a specific issue. Thank you for the report!