During the investigation of this ticket, @MSECode and I noticed some bugs in the
Ethernet calibrator
.DEBUG] Left_Arm_Calibrator : Joints calibration order:
checkHWFault
function performed a loop on the joints in (0, totJointsToCalibrate) range instead of on the list containing the required joints.checkHWFault
function was ignored.We fixed them in this way:
1.
checkHWFault
functionResults:
Here there are the logs of the left arm during calibration where the joint number 9 is omitted
Before
After