You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
This issue will track the progress for enabling support for dumping the required fields for TRANSCEIVER_DOM_THRESHOLD through 'show int transceiver eeprom threshold' CLI
Sample output of the CLI (the "show interfaces Ethernet4/21/1 transceiver detail" CLI will be changed to something else to be more specific to display DOM threshold values):
YQB20-0201-0100-03T2(s1)#show interfaces Ethernet4/21/1 transceiver detail
mA: milliamperes, dBm: decibels (milliwatts), NA or N/A: not applicable.
A2D readouts (if they differ), are reported in parentheses.
The threshold values are calibrated.
High Alarm High Warn Low Alarm Low Warn
Temperature Threshold Threshold Threshold Threshold
Port (Celsius) (Celsius) (Celsius) (Celsius) (Celsius)
------- ------------ ---------- ---------- ---------- ----------
Et4/21/1 25.00 85.00 80.00 -15.00 -10.00
High Alarm High Warn Low Alarm Low Warn
Voltage Threshold Threshold Threshold Threshold
Port (Volts) (Volts) (Volts) (Volts) (Volts)
------- ------------ ---------- ---------- ---------- ----------
Et4/21/1 3.26 3.60 3.50 2.90 3.00
High Alarm High Warn Low Alarm Low Warn
Current Threshold Threshold Threshold Threshold
Port (mA) (mA) (mA) (mA) (mA)
------- ------------ ---------- ---------- ---------- ----------
Et4/21/1 23.27 54.37 53.42 0.00 0.00
High Alarm High Warn Low Alarm Low Warn
Tx Power Threshold Threshold Threshold Threshold
Port (dBm) (dBm) (dBm) (dBm) (dBm)
------- ------------ ---------- ---------- ---------- ----------
Et4/21/1 N/A N/A N/A N/A N/A
High Alarm High Warn Low Alarm Low Warn
Rx Power Threshold Threshold Threshold Threshold
Port (dBm) (dBm) (dBm) (dBm) (dBm)
------- ------------ ---------- ---------- ---------- ----------
Et4/21/1 -3.07 0.00 -0.46 -16.02 -13.01
YQB20-0201-0100-03T2(s1)#
Steps to reproduce the issue:
Describe the results you received:
Describe the results you expected:
Output of show version:
(paste your output here)
Output of show techsupport:
(paste your output here or download and attach the file here )
Additional information you deem important (e.g. issue happens only occasionally):
The text was updated successfully, but these errors were encountered:
Description
This issue will track the progress for enabling support for dumping the required fields for TRANSCEIVER_DOM_THRESHOLD through 'show int transceiver eeprom threshold' CLI
Sample output of the CLI (the "show interfaces Ethernet4/21/1 transceiver detail" CLI will be changed to something else to be more specific to display DOM threshold values):
Steps to reproduce the issue:
Describe the results you received:
Describe the results you expected:
Output of
show version
:Output of
show techsupport
:Additional information you deem important (e.g. issue happens only occasionally):
The text was updated successfully, but these errors were encountered: