fanshow and fan management are broken on Dell N3248TE-ON and current release #16666
Comments
@jeff-yin Could you check with this plartform in master ? |
As I'm becoming more comfortable with SONiC, I wonder if the fact that I don't have a second PSU installed might be playing into this. I've noticed that sometimes small configuration changes can cause problems in modules that have different expectations. I don't have a second PSU to plug in, but that might be something to investigate. |
Usually the fans will go to 100% when a FAN module is removed. I don't think lacking a PSU would trigger this. |
I checked last night to see that all 3 fan modules were running and they're all moving air. The LEDs on all of them are off. |
The speed of the fans does not seem to be dependent on the PSU presence, but the display of the status does. I picked up a second PSU and the command
So they aren't running at 100%, but they are running at a constant higher speed than the default software (Dell OS6, I believe) that came on the switch. Maybe that's normal? It seems like the temperatures could tolerate a less aggressive setting.
Also, |
@justindthomas .. will be raising the pull request to fix the commands 'show environment' and 'show platform fan' by next week. |
That's great, @arunlk-dell - thanks! |
For the fan speed issues, I was able to tame them by adjusting these values:
By default, these are all set to Does that parameter adjust the aggressiveness of the thermal algorithm? I experimented with changing the |
Here's the corrected Should I submit a PR? I assume this belongs in platform-specific code somewhere. #!/usr/bin/python
# This provies support for the following objects:
# * Onboard temperature sensors
# * FAN trays
# * PSU
import subprocess
output = ""
try:
rc = 0
output = subprocess.check_output('/usr/bin/sensors', text=True).splitlines()
valid = False
for line in output:
if line.startswith('acpitz') or line.startswith('coretemp'):
valid = True
if valid:
print(line)
if line == '': valid = False
print("Onboard Temperature Sensors:")
idx = 0
for line in output:
if line.startswith('tmp75'):
print('\t' + output[idx+2].split('(')[0])
idx += 1
print("\nFanTrays:")
idx = 0
found_emc = False
for line in output:
if line.startswith('emc'):
found_emc = True
with open('/sys/devices/platform/dell-n3248te-cpld.0/fan0_prs') as f:
line = f.readline()
present = int(line, 0)
if present :
print('\t' + 'FanTray1:')
print('\t\t' + 'Fan Speed:' + (output[idx+2].split('(')[0]).split(':')[1])
with open('/sys/devices/platform/dell-n3248te-cpld.0/fan0_dir') as f:
line = f.readline()
dir = 'Intake' if line[:-1] == 'B2F' else 'Exhaust'
print('\t\t' + 'Airflow:\t' + dir)
else : print('\t' + 'FanTray1:\tNot Present')
with open('/sys/devices/platform/dell-n3248te-cpld.0/fan1_prs') as f:
line = f.readline()
present = int(line, 0)
if present :
print('\t' + 'FanTray2:')
print('\t\t' + 'Fan Speed:' + (output[idx+3].split('(')[0]).split(':')[1])
with open('/sys/devices/platform/dell-n3248te-cpld.0/fan1_dir') as f:
line = f.readline()
dir = 'Intake' if line[:-1] == 'B2F' else 'Exhaust'
print('\t\t' + 'Airflow:\t' + dir)
else : print('\t' + 'FanTray2:\tNot Present')
with open('/sys/devices/platform/dell-n3248te-cpld.0/fan2_prs') as f:
line = f.readline()
present = int(line, 0)
if present :
print('\t' + 'FanTray3:')
print('\t\t' + 'Fan Speed:' + (output[idx+4].split('(')[0]).split(':')[1])
with open('/sys/devices/platform/dell-n3248te-cpld.0/fan2_dir') as f:
line = f.readline()
dir = 'Intake' if line[:-1] == 'B2F' else 'Exhaust'
print('\t\t' + 'Airflow:\t' + dir)
else : print('\t' + 'FanTray3:\tNot Present')
idx += 1
if not found_emc :
print('\t' + 'FanTray1:\tNot Present')
print('\t' + 'FanTray2:\tNot Present')
print('\t' + 'FanTray3:\tNot Present')
print('\nPSUs:')
idx = 0
with open('/sys/devices/platform/dell-n3248te-cpld.0/psu0_prs') as f:
line = f.readline()
found_psu1 = int(line, 0)
if not found_psu1 :
print('\tPSU1:\tNot Present')
with open('/sys/devices/platform/dell-n3248te-cpld.0/psu1_prs') as f:
line = f.readline()
found_psu2 = int(line, 0)
for line in output:
if line.startswith('dps460-i2c-10'):
with open('/sys/devices/platform/dell-n3248te-cpld.0/psu0_status') as f:
line = f.readline()
status = int(line, 0)
if not status :
print('\tPSU1:\tNot OK')
break
with open('/sys/bus/i2c/devices/10-0056/eeprom', encoding='iso-8859-1') as f:
line = f.readline()
dir = 'Exhaust' if 'FORWARD' in line else 'Intake'
print('\tPSU1:')
print('\t\t' + output[idx+2].split('(')[0])
print('\t\t' + output[idx+4].split('(')[0])
print('\t\t' + output[idx+6].split('(')[0])
print('\t\t' + output[idx+7].split('(')[0])
print('\t\t' + output[idx+9].split('(')[0])
print('\t\t' + output[idx+11].split('(')[0])
print('\t\t' + output[idx+12].split('(')[0])
print('\t\t' + output[idx+14].split('(')[0])
print('\t\t' + output[idx+15].split('(')[0])
print('\t\t' + 'Airflow:\t\t ' + dir)
if line.startswith('dps460-i2c-11'):
with open('/sys/devices/platform/dell-n3248te-cpld.0/psu1_status') as f:
line = f.readline()
status = int(line, 0)
if not status :
print('\tPSU2:\tNot OK')
break
print('\tPSU2:')
with open('/sys/bus/i2c/devices/11-0056/eeprom', encoding='iso-8859-1') as f:
line = f.readline()
dir = 'Exhaust' if 'FORWARD' in line else 'Intake'
print('\t\t' + output[idx+2].split('(')[0])
print('\t\t' + output[idx+4].split('(')[0])
print('\t\t' + output[idx+6].split('(')[0])
print('\t\t' + output[idx+7].split('(')[0])
print('\t\t' + output[idx+9].split('(')[0])
print('\t\t' + output[idx+11].split('(')[0])
print('\t\t' + output[idx+12].split('(')[0])
print('\t\t' + output[idx+14].split('(')[0])
print('\t\t' + output[idx+15].split('(')[0])
print('\t\t' + 'Airflow:\t\t ' + dir)
idx += 1
if not found_psu2 :
print('\tPSU2:\tNot Present')
except subprocess.CalledProcessError as err:
print ("Exception when calling get_sonic_error -> %s\n" %(err))
rc = err.returncode |
PR submitted here: #17508 |
Description
I'm new to SONiC and installed it on a Dell N3248TE-ON I received a couple of days ago. On initial boot, the switch actively managed the fans (i.e., speed was constantly changing, presumably in response to load, but was at an average pretty quiet speed).
After installing SONiC, the fans just run at a high (loud) speed constantly. Commands to show the fan status fail with Python errors.
Steps to reproduce the issue:
show platform fan
show environment
Describe the results you received:
show platform fan
show environment
Describe the results you expected:
Output of
show version
:Output of
show techsupport
:techsupport.txt
Additional information you deem important (e.g. issue happens only occasionally):
The dump file is 31MB and GitHub rejects files over 25MB.
The text was updated successfully, but these errors were encountered: