Notifications
You must be signed in to change notification settings - Fork 0
/
kitchen_floor.lua
133 lines (126 loc) · 5.73 KB
/
kitchen_floor.lua
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
return {
active = true,
on = {
devices = {
-- temp sensors
't_ext',
'TH Kitchen',
-- 'TH Kitchen2',
-- 'THB Kitchen',
-- setpoints
'H Kitchen',
-- switches
'H/C',
-- heatpump control
'Heatpump cooling', 'Heatpump heating',
-- floors/radiators
'Floor kitchen'
}
},
data = {
hist_ki = { history = true, maxMinutes = 40 }
},
execute = function(dz, item)
t_ext = dz.devices('t_ext')
hco = dz.devices('H/C')
hpc = dz.devices('Heatpump cooling')
hph = dz.devices('Heatpump heating')
hysteresis_h = 0.1
hysteresis_l = 0.1
-- slope = 0.4
h_ki = dz.devices('H Kitchen')
r_ki = dz.devices('Floor kitchen')
t_ki = dz.devices('TH Kitchen')
if item.name == 'TH Kitchen' then
dz.log('update data.hist_ki')
dz.data.hist_ki.add(t_ki.temperature)
end
-- p_ki = dz.data.hist_ki.deltaSince('00:20:00', 1, 0) * 6 + t_ki.temperature
p_ki = (dz.data.hist_ki.avg(1,6) - dz.data.hist_ki.avg(21,26)) * 6 + dz.data.hist_ki.avg(1,6)
if p_ki == 0 then
p_ki = t_ki.temperature
dz.notify('t_ki sensor issue')
end
dz.log('ki t_ext.temperature ' .. t_ext.temperature)
dz.log('ki dz.variables(hd_ki).value ' .. dz.variables('hd_ki').value)
dz.log('ki dz.variables(hd_ki).lastUpdate.minutesAgo ' .. dz.variables('hd_ki').lastUpdate.minutesAgo)
dz.log('ki dz.variables(hph_delayed_off).value ' .. dz.variables('hph_delayed_off').value)
dz.log('ki dz.variables(hph_delayed_on).value ' .. dz.variables('hph_delayed_on').value)
dz.log('ki dz.variables(hph_delayed_on).lastUpdate.minutesAgo ' .. dz.variables('hph_delayed_on').lastUpdate.minutesAgo)
-- dz.log('ki dz.variables(hs_ki).value ' .. dz.variables('hs_ki').value)
dz.log('ki h_ki.setPoint ' .. h_ki.setPoint)
dz.log('ki hph.lastUpdate.minutesAgo ' .. hph.lastUpdate.minutesAgo)
dz.log('ki hph.state ' .. hph.state)
dz.log('ki ki_avg0 ' .. dz.data.hist_ki.avg(0,5))
dz.log('ki ki_avg20 ' .. dz.data.hist_ki.avg(20,25))
dz.log('ki p_ki ' .. p_ki)
dz.log('ki r_ki.state ' .. r_ki.state)
if hco.state == 'Cooling' then
dz.log('hco.state cooling')
elseif hco.state == 'Heating' then
-- Turning on
-- if (t_ki.temperature < (h_ki.setPoint - hysteresis_l) or p_ki < (h_ki.setPoint - hysteresis_l)) and t_ext.temperature < 15.5 then
if t_ki.temperature < (h_ki.setPoint - hysteresis_l) or p_ki < (h_ki.setPoint - hysteresis_l) then
dz.log('ki heating demand')
if dz.variables('hd_ki').value == 0 then
dz.log('### hd_ki set 1')
dz.variables('hd_ki').set(1)
end
if r_ki.state == 'Off' then
dz.log('### r_ki.switchOn() 1 ###')
r_ki.switchOn()
end
-- Turning off
-- elseif (t_ki.temperature >= (h_ki.setPoint + hysteresis_h) and p_ki >= (h_ki.setPoint + hysteresis_h)) or t_ext.temperature > 15.5 then
elseif t_ki.temperature >= (h_ki.setPoint + hysteresis_h) and p_ki >= (h_ki.setPoint + hysteresis_h) then
dz.log('ki no heating demand')
if dz.variables('hd_ki').value ~= 0 then
dz.log('### hd_ki set 0')
dz.variables('hd_ki').set(0)
end
-- if t_ext.temperature < 2.1 and (hph.state == 'Off' or dz.variables('hd_ki').lastUpdate.minutesAgo < 45) then
if t_ext.temperature < 2.1 and (hph.state == 'Off' and dz.variables('hph_delayed_on').value == 0) then
if r_ki.state == 'Off' then
dz.log('### r_ki.switchOn 2 ###')
r_ki.switchOn()
end
-- elseif (hph.state == 'Off' and dz.variables('hph_delayed_on').value == 0) or (hph.state == 'On' and (dz.variables('hd_ki').lastUpdate.minutesAgo > 45 or hph.lastUpdate.minutesAgo > 45)) then
elseif (hph.state == 'Off' and dz.variables('hph_delayed_on').value == 0) or (hph.state == 'On' and hph.lastUpdate.minutesAgo > 45) then
if r_ki.state == 'On' and r_ki.lastUpdate.minutesAgo > 5 then
dz.log('### r_ki.switchOff() 1 ###')
r_ki.switchOff()
end
end
else
dz.log('ki between hysteresis')
end
-- diff_setpoint_temp = ( h_ki.setPoint - t_ki.temperature)
-- if diff_setpoint_temp > 0.4 then hs = 0.8 -- slope + 0.4
-- elseif diff_setpoint_temp > 0.3 then hs = 0.7 -- slope + 0.3
-- elseif diff_setpoint_temp > 0.2 then hs = 0.6 -- slope + 0.2
-- elseif diff_setpoint_temp > 0.1 then hs = 0.5 -- slope + 0.1
-- else hs = 0.4 -- slope
---- elseif diff_setpoint_temp > 0 then hs = 0.4 -- slope
---- else hs = 0.3 -- slope - 0.1
-- end
-- if (dz.variables('hs_ki').value ~= hs) then
-- dz.log('### hs_ki set ' .. hs)
-- dz.variables('hs_ki').set(hs)
-- end
elseif hco.state == 'Off' then
dz.log('hco.state Off')
-- Frost protection, open all valves
if t_ext.temperature < 2.1 then
if r_ki.state == 'Off' then
r_ki.switchOn()
end
elseif hpc.state == 'Off' and hpc.lastUpdate.minutesAgo > 3 and hph.state == 'Off' and hph.lastUpdate.minutesAgo > 3 then
if r_ki.state == 'On' then
r_ki.switchOff()
end
end
elseif hco.state == 'Manual' then
dz.log('hco.state Manual')
end
end
}