Need New UPS #894
Comments
Tested and UPS work. There is an exception case where they will fail. The Power Goes out, the PW2 is at 100% and the sun is shining. This raises the frequency to potentially 63 which is no good for the UPS. The eaton below will operate all the way up to 66 which is perfect. So if this is an issue or when the APC UPS does eventually die, this should be the replacement. SOmething that accepts input frequencies of 50/60 + 6hz. Additional Information:
|
UPS finally died. Time for a new one. |
Time to buy this one: Bigger unit to consolidate all the plugs and power strips. |
Will need to figure this out as well.
|
REPLACEMENT Battery for BGE70 Not sure if I need it with the new EATON 3S but if I do, it's a pretty cheap replacement. |
Found a cheaper replacement with 6 outlets rather than 3 for the same price as the Battery Replacement. |
https://youtube.com/shorts/4R1DcC3qQG4
|
https://www.vcloudinfo.com/2022/10/why-i-added-the-eaton-3s-ups-to-my-tesla-powerwall-setup.html
|
The old APC is dead. Need to replace it.