#!/bin/bash
# IPMI IP address
IPMIHOST=10.100.0.18
# IPMI Username
IPMIUSER=XXXXXXX
# IPMI Password
IPMIPW=XXXXXXXXXXXX
# Your IPMI Encryption Key
IPMIEK=0000000000000000000000000000000000000000
# Maximum ambient temperature in Celsius
MAXTEMP_AMBIENT=31
# Maximum processor temperature in Celsius
MAXTEMP_PROC=70
# Get the inlet temperature
INLET_TEMP=$(ipmitool -I lanplus -H $IPMIHOST -U $IPMIUSER -P $IPMIPW -y $IPMIEK sdr type temperature | grep "Inlet Temp" | grep degrees | grep -Po '\d{2}' | tail -1)
# Get the processor temperatures
PROC_TEMP1=$(ipmitool -I lanplus -H $IPMIHOST -U $IPMIUSER -P $IPMIPW -y $IPMIEK sdr type temperature | grep "0Eh" | grep degrees | grep -Po '\d{2}' | tail -1)
PROC_TEMP2=$(ipmitool -I lanplus -H $IPMIHOST -U $IPMIUSER -P $IPMIPW -y $IPMIEK sdr type temperature | grep "0Fh" | grep degrees | grep -Po '\d{2}' | tail -1)
# Determine fan speed based on ambient temperature
if [[ $INLET_TEMP -ge 0 && $INLET_TEMP -le 14 ]]; then
FANSPEED=20
elif [[ $INLET_TEMP -ge 15 && $INLET_TEMP -le 19 ]]; then
FANSPEED=40
elif [[ $INLET_TEMP -ge 20 && $INLET_TEMP -le 26 ]]; then
FANSPEED=60
elif [[ $INLET_TEMP -ge 27 && $INLET_TEMP -le 30 ]]; then
FANSPEED=80
fi
# Convert fan speed to hex
SPEEDHEX=$( printf "%x" $FANSPEED )
# Check if any processor temperature exceeds or equals the maximum temperature
if [[ $PROC_TEMP1 -ge $MAXTEMP_PROC || $PROC_TEMP2 -ge $MAXTEMP_PROC ]];
then
printf "Warning: Processor temperature is too high! Activating dynamic fan control! (Proc1: $PROC_TEMP1 C, Proc2: $PROC_TEMP2 C)" | systemd-cat -t R730XD-IPMI-TEMP
echo "Warning: Processor temperature is too high! Activating dynamic fan control! (Proc1: $PROC_TEMP1 C, Proc2: $PROC_TEMP2 C)"
# This sets the fans to auto mode, so the motherboard will set it to a speed that it will need to cool the server down
ipmitool -I lanplus -H $IPMIHOST -U $IPMIUSER -P $IPMIPW -y $IPMIEK raw 0x30 0x30 0x01 0x01
elif [[ $INLET_TEMP -ge $MAXTEMP_AMBIENT ]];
then
printf "Warning: Ambient temperature is too high! Activating dynamic fan control! (Inlet: $INLET_TEMP C)" | systemd-cat -t R730XD-IPMI-TEMP
echo "Warning: Ambient temperature is too high! Activating dynamic fan control! (Inlet: $INLET_TEMP C)"
# This sets the fans to auto mode, so the motherboard will set it to a speed that it will need to cool the server down
ipmitool -I lanplus -H $IPMIHOST -U $IPMIUSER -P $IPMIPW -y $IPMIEK raw 0x30 0x30 0x01 0x01
else
printf "Temperature is OK (Inlet: $INLET_TEMP C, Proc1: $PROC_TEMP1 C, Proc2: $PROC_TEMP2 C)" | systemd-cat -t R730XD-IPMI-TEMP
echo "Activating manual fan speeds! ($FANSPEED%)"
# This sets the fans to manual mode
ipmitool -I lanplus -H $IPMIHOST -U $IPMIUSER -P $IPMIPW -y $IPMIEK raw 0x30 0x30 0x01 0x00
# This is where we set the slower, quiet speed
ipmitool -I lanplus -H $IPMIHOST -U $IPMIUSER -P $IPMIPW -y $IPMIEK raw 0x30 0x30 0x02 0xff 0x$SPEEDHEX
fi