Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Queued commands not executed causing tool change to hang #998

Open
dc42 opened this issue May 10, 2024 · 1 comment
Open

Queued commands not executed causing tool change to hang #998

dc42 opened this issue May 10, 2024 · 1 comment
Assignees
Labels
bug Bug that has been reproduced
Milestone

Comments

@dc42
Copy link
Collaborator

dc42 commented May 10, 2024

We have an example of tool changes hanging because queued commands are not executing. See https://forum.duet3d.com/topic/35641/printer-hanging-during-tool-change-with-v3-5-1.

@dc42 dc42 added this to the 3.5.2 milestone May 10, 2024
@dc42 dc42 self-assigned this May 10, 2024
@T3P3 T3P3 added the bug Bug that has been reproduced label May 14, 2024
@T3P3
Copy link
Contributor

T3P3 commented May 22, 2024

suggested workaround that appears to work:

insert a M400 or G4 P0 command before the M98 P"/sys/tconfig0.g" line at the end of tpre0.g

Probably only affects macros that call other macros as the last command.

@T3P3 T3P3 modified the milestones: 3.5.2, After 3.5.2 May 22, 2024
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment