Calculation for time to drain WEP capacitor seems to be incorrect #751

Open
chennin opened this issue May 13, 2024 · 1 comment
Open

Calculation for time to drain WEP capacitor seems to be incorrect #751

chennin opened this issue May 13, 2024 · 1 comment
Labels
beta Bug that is present in beta bug

Comments

@chennin
Copy link

chennin commented May 13, 2024

When comparing TTD WEP, I noticed a discrepancy. For testing, we used Stock Python (7E distro, two pips to WEP, two fixed 1F pulse lasers).

coriolis shows a TTD of 2m39s

image

EDSY shows 1m44s

image

testing ingame shows about 1m46s, which is pretty far off coriolis. Far enough that it doesn't look like a rounding error.

I also noticed the issue with a Python Mk2 and multicannons.

I don't fully understand the code, but I did find where I think it is: coriolis and EDSY.

If coriolis is overestimating the TTD then I have definitely been misjudging some builds' viability.

@alex-williams alex-williams added bug beta Bug that is present in beta labels May 14, 2024
@alex-williams
Copy link
Collaborator

Confirmed, saw the test in EDCD Discord. Link provided to code that does the calculation is correct, calculation breaks somewhere and needs to be investigated.