variable name,data type,register,documented name,description,writable,values,unit,note
2+
,BYTE,0x000B,Product type,,R,"{""0"": ""domestic controller"", ""1"": ""controller for street light"", ""3"": ""grid-connected inverter"", ""4"": ""all-in-one solar charger inverter"", ""5"": ""power frequency off-grid""}",,
3+
,,x14,Software version 1,,R,,0.01,
4+
,,x15,Software version 2,,R,,0.01,
5+
,,x16,Hardware version 1,,R,,0.01,
6+
,,x17,Hardware version 2,,R,,0.01,
7+
,,0x001A,RS485 address,,R,1~247,,
8+
,,x1B,Model Code,,R,,,
9+
,,0x001C,RS485 version,,R,,0.01,
10+
,ASCII,x21~x34,software compilation time ,,R,,,
11+
,ASCII,0x0035~0x0048,Product SN,,R,,,
12+
,,0x0100,Battery capacity SOC,,R,0~100,%,
13+
,,0x0101,Battery voltage,,R,,0.1V,
14+
,SHORT,0x0102,Battery current,,R,,0.1A,
15+
,BYTE,x103,Controller temperature,,R,,C,
16+
,BYTE,x103.b8,Battery temperature,,R,,C,
17+
,,x104,Load DC Voltage,,R,,0.1V,
18+
,,x105,Load DC Current,,R,,0.01A,
19+
,,x106,Load DC Power,,R,,W,
20+
,,0x0107,PV1 voltage,,R,,0.1V,
21+
,,0x0108,PV1 current,,R,,0.1A,
22+
,,0x0109,PV1 power,,R,,W,
23+
,,0x010F,PV2 voltage,,R,,0.1V,
24+
,,0x0110,PV2 current,,R,,0.1A,
25+
,,0x0111,PV2 power,,R,,W,
26+
,,0x010B,Device Charge state,,R,"{""0"": ""Charge off"", ""1"": ""Quick charge"", ""2"": ""Const voltage charge"", ""4"": ""Float charge"", ""6"": ""Li battery activate"", ""8"": ""Full""}",,
27+
,,0x010E,Device Total charging power,,R,,W,
28+
,16BIT_FLAGS,x200,Fault Bits 1,,R,,,
29+
,16BIT_FLAGS,x201,Fault Bits 2,,R,,,
30+
,16BIT_FLAGS,x202,Fault Bits 3,,R,,,
31+
,16BIT_FLAGS,x203,Fault Bits 4,,R,,,
32+
,,x204,Fault Code 1,,R,,,
33+
,,x205,Fault Code 2,,R,,,
34+
,,x206,Fault Code 3,,R,,,
35+
,,x207,Fault Code 4,,R,,,
36+
,BYTE,x20C,Current Time Year,,RW,,,
37+
,BYTE,x20C.b8,Current Time Month,,RW,,,
38+
,BYTE,x21D,Current Time Day,,RW,,,
39+
,BYTE,x21D.b8,Current Time Hour,,RW,,,
40+
,BYTE,x21E,Current Time Minute,,RW,,,
41+
,BYTE,x21E.b8,Current Time Second,,RW,,,
42+
,,0x0210,Device state,,R,"{""0"":""Power-up delay"",""1"":""Waiting state"",""2"":""Initialization"",""3"":""Soft start"",""4"":""Mains powered operation"",""5"":""Inverter powered operation"",""6"":""Inverter to mains"",""7"":""Mains to inverter"",""8"":""Battery activate"",""9"":""Shutdown by user"",""10"":""Fault""}",,
43+
,,x211,Password protection status mark ,,R,"{""0"":""No password entered by the user"",""1"":""User password has been entered"",""4"":""Manufacturer password has been entered""}",,
44+
,,0x0212,Device Bus Voltage Sum,,R,,0.1V,
45+
,,0x0213,Grid phase-A voltage,,R,,0.1V,
46+
,,0x0214,Grid phase-A current,,R,,0.1A,
47+
,,0x0215,Grid frequency,,R,,0.01Hz,
48+
,,0x0216,Inverter phase-A output voltage,,R,,0.1V,
49+
,,0x0217,Inverter phase-A inductive current,,R,,0.1A,
50+
,,0x0218,Inverter frequency,,R,,0.01Hz,
51+
,,0x0219,Load Phase-A current,,R,,0.1A,
52+
,,x21A,Load PF,,R,,0.01,
53+
,,0x021B,Load Phase-A active power,,R,,W,
54+
,,0x021C,Load Phase-A apparent power,,R,,VA,
55+
,,x21D,Inverter DC Component,,R,,1mV,
56+
,,x21E,Mains charge current ,,R,,0.1A,
57+
,,0x021F,Load Phase-A ratio,,R,0~100,%,
58+
,,x220,DC-DC heat sink temperature ,,R,,0.1C,
59+
,,x221,DC-AC heat sink temperature ,,R,,0.1C,
60+
,,x222,Translator heat sink temperature ,,R,,0.1C,
61+
,,x223,Heat sink D temperature ,,R,,0.1C,
62+
,,x224,PV Charge Current,,R,,0.1A,
63+
,,x225,Ibuck2 Current,,R,,0.1A,
64+
,,x226,Inverter fault state ,,R,,,
65+
,,x227,Charge status ,,R,,,
66+
,,x228,PBusVolt ,,R,,0.1V,
67+
,,x229,NBusVolt ,,R,,0.1V,
68+
,,0x022A,Grid phase-B voltage,,R,,0.1V,
69+
,,0x022B,Grid phase-C voltage,,R,,0.1V,
70+
,,0x022C,Inverter phase-B output voltage,,R,,0.1V,
71+
,,0x022E,Inverter phase-B inductive current,,R,,0.1A,
72+
,,0x022D,Inverter phase-C output voltage,,R,,0.1V,
73+
,,0x022F,Inverter phase-C inductive current,,R,,0.1A,
74+
,,0x0230,Load Phase-B current,,R,,0.1A,
75+
,,0x0231,Load Phase-C current,,R,,0.1A,
76+
,,0x0232,Load Phase-B active power,,R,,W,
77+
,,0x0233,Load Phase-C active power,,R,,W,
78+
,,0x0234,Load Phase-B apparent power,,R,,VA,
79+
,,0x0235,Load Phase-C apparent power,,R,,VA,
80+
,,0x0236,Load Phase-B ratio,,R,0~100,%,
81+
,,0x0237,Load Phase-C ratio,,R,0~100,%,
82+
,,,,,,,,
83+
,,xE001,PV charge current limit ,,RW,0~100,0.1A,
84+
,,xE002,Nominal battery capacity ,,RW,0~400,1AH,
85+
,,xE003,System Voltage,,R,12~255,V,
86+
,,xE004,Battery Type,,RW,"{""0"":""User define"",""1"":""SLD"",""2"":""FLD""}",,
87+
,,xE005,Battery Over Voltage,,RW,9~15.5,0.1V,
88+
,,xE006,Limited Charge Voltage,,RW,9~15.5,0.1V,
89+
,,xE007,Equalizing charge voltage ,,RW,9~15.5,0.1V,
90+
,,xE008,Boost Charge Voltage Or Lithium Over Voltage,,RW,9~15.5,0.1V,
91+
,,xE009,Float Charge Voltage Or Lithium Over Charge Return Voltage,,RW,9~15.5,0.1V,
92+
,,xE00A,Boost charge return voltage ,,RW,9~15.5,0.1V,
93+
,,xE00B,Over discharge return voltage ,,RW,9~15.5,0.1V,
94+
,,xE00C,Under-voltage warning voltage ,,RW,9~15.5,0.1V,
95+
,,xE00D,Over discharge voltage ,,RW,9~15.5,0.1V,
96+
,,xE00E,Limited discharge voltage ,,RW,9~15.5,0.1V,
97+
,BYTE,xE00F,Charge Cutoff SOC,,RW,0~100,%,
98+
,BYTE,xE00F.b8,Discharge Cuttoff SOC,,RW,0~100,%,
99+
,,xE010,Over discharge delay time ,,RW,0~120,S,
100+
,,xE011,Equalizing charge time ,,RW,0~600,Min,
101+
,,xE012,Boost charge time ,,RW,0~600,Min,
102+
,,xE013,Equalizing charge interval ,,RW,0~255,Day,
103+
,,xE014,Temperature compensation coefficient ,,RW,0~10,mV/C/2V ,
104+
,SHORT,xE015,Charge upper limit temperature ,,RW,Err:502,C,
105+
,SHORT,xE016,Charge lower limit temperature ,,RW,Err:502,C,
106+
,SHORT,xE017,Discharge upper limit temperature ,,RW,Err:502,C,
107+
,SHORT,xE018,DisChgMinTemperature,,RW,Err:502,C,
108+
,SHORT,xE019,HeatBatStartTemperature,,RW,Err:502,C,
109+
,SHORT,xE01A,HeatBatStopTemperature ,,RW,Err:502,C,
110+
,,xE01B,Mains switching voltage ,,RW,9~15.5,0.1V,
111+
,,xE01C,Stop charging current ,,RW,0~40,0.1A,
112+
,,xE01D,DC load working mode ,,RW,,,
113+
,,xE01E,Light control delay time,,RW,0~60,Min,
114+
,,xE01F,Light control voltage ,,RW,1~45,V,
115+
,,xE020,1 Number of batteries connected in series ,,RW,1~200,,
116+
,,xE021,Special power control ,,RW,,,
117+
,,xE022,Inverter switching voltage ,,RW,9~15.5,0.1V,
118+
,,xE023,Equalizing charge timeout time ,,RW,5~900,Min,
119+
,,xE024,Lithium battery activation current ,,RW,0~10,A,
120+
,,,,,,,,
121+
,,xE026,1-section start charging time,hour and minute:23*256+59==5947 ,RW,0~ 5947 ,Min,
122+
,,xE027,1-section stop charging time,,RW,0~ 5947 ,Min,
123+
,,xE028,2-section start charging time,,RW,0~ 5947 ,Min,
124+
,,xE029,2-section stop charging time,,RW,0~ 5947 ,Min,
125+
,,xE02A,3-section start charging time,,RW,0~ 5947 ,Min,
126+
,,xE02B,3-section stop charging time,,RW,0~ 5947 ,Min,
127+
,,xE02C,Sectional charging function enable,,RW,"{""0"":""Disable"",""1"":""Enable""}",,
128+
,,xE02D,1-section start discharging time,,RW,0~ 5947 ,Min,
129+
,,xE02E,1-section stop discharging time,,RW,0~ 5947 ,Min,
130+
,,xE02F,2-section start discharging time,,RW,0~ 5947 ,Min,
131+
,,xE030,2-section stop discharging time,,RW,0~ 5947 ,Min,
132+
,,xE031,3-section start discharging time,,RW,0~ 5947 ,Min,
133+
,,xE032,3-section stop discharging time,,RW,0~ 5947 ,Min,
134+
,,xE033,Sectional discharging function enable,,RW,"{""0"":""Disable"",""1"":""Enable""}",,
135+
,,xE034,current time setup year month,E034 - year and month:99*256+12==25356 ,RW,0~ 25356 ,Yr/Mo,
136+
,,xE035,current time setup day hour,E035 -day and hour:31*256+23==7959 ,RW,0~7959,Day/Hr,
137+
,,xE036,current time setup min second,E036 -minute and second:59*256+59==15163 ,RW,0~ 15163,Min/Sec,
138+
,,xE037,PV grid-connected power generation enable,,,"{""0"":""Disable"",""1"":""Enable""}",,
139+
,,xE038,GFCI Enable,,,"{""0"":""Disable"",""1"":""Enable""}",,
140+
,,,,,,,,
141+
,,xE200,Inverter 485 address setup,,RW,1~254,,
142+
,,xE201,Inverter parallel mode setup,,RW,0~7,,
143+
,,xE202,User password set value,,W,0~65535,,
144+
,,xE203,Password input,,W,0~65535,,
145+
,,,,,,,,
146+
,,xE204,Output priority,,RW,"{""0"":""solar"",""1"":""line"",""2"":""sbu""}",,
147+
,,xE205,Mains charge current limit,,RW,0~100,0.1A,
148+
,,xE206,Equalizing charge enable,,RW,,,
149+
,,xE207,Power save level,,RW,0~1000,W,
150+
,,xE208,Output voltage,,RW,100~264,0.1V,
151+
,,xE209,Output frequency,,RW,45~65,0.01Hz,
152+
,,xE20A,Maximum charge current,,RW,0~150,0.1A,
153+
,,xE20B,AC input range,,RW,"{""0"":""wide range (APL)"",""1"":""narrow range (UPS)""}",,
154+
,,xE20C,Eco mode,,RW,"{""0"":""Disable"",""1"":""Enable""}",,
155+
,,xE20D,Overload auto restart,,RW,"{""0"":""Disable"",""1"":""Enable""}",,
156+
,,xE20E,Over temperature auto restart,,RW,"{""0"":""Disable"",""1"":""Enable""}",,
157+
,,xE20F,Charge priority,,RW,"{""0"":""PV preferred, only start mains charging when PV is not available"",""1"":""Mains preferred, only start PV charging when mains is not available"",""2"":""Hybrid mode, mains and PV charging at the same time, PV is preferred"",""3"":""PV only, mains does not charge""}",,
158+
,,xE210,Alarm control,,RW,"{""0"":""Disable"",""1"":""Enable""}",,
159+
,,xE211,Alarm enable when input source is interrupted,,RW,"{""0"":""Disable"",""1"":""Enable""}",,
160+
,,xE212,Overload bypass enable,,RW,"{""0"":""Disable"",""1"":""Enable""}",,
161+
,,xE213,Record fault code,,RW,"{""0"":""Disable"",""1"":""Enable""}",,
162+
,,xE214,Split-phase transformer,,RW,"{""0"":""Disable"",""1"":""Enable""}",,
163+
,,xE215,BMS communication enable,,RW,"{""0"":""Disable"",""1"":""Enable""}",,
164+
,,xE216,Start charge time setup,,RW,0~23,,
165+
,,xE217,Start discharge time setup,,RW,0~23,,
166+
,,,,,,,,
167+
,UINT,xE219,UniqueIDcode,,R,,,
168+
,,xE21B,BMS protocol,,RW,0~30,,
169+
,,,,,,,,
170+
,,xF000,History PV power generation Today Minus 1,,R,,AH,
171+
,,xF001,History PV power generation Today Minus 2,,R,,AH,
172+
,,xF002,history PV power generation Today Minus 3,,R,,AH,
173+
,,xF003,history PV power generation Today Minus 4,,R,,AH,
174+
,,xF004,history PV power generation Today Minus 5,,R,,AH,
175+
,,xF005,history PV power generation Today Minus 6,,R,,AH,
176+
,,xF006,history PV power generation Today Minus 7,,R,,AH,
177+
,,,,,,,,
178+
,,xF007,history battery charge level Today Minus 1,,R,,AH,
179+
,,xF008,history battery charge level Today Minus 2,,R,,AH,
180+
,,xF009,history battery charge level Today Minus 3,,R,,AH,
181+
,,xF00A,history battery charge level Today Minus 4,,R,,AH,
182+
,,xF00B,history battery charge level Today Minus 5,,R,,AH,
183+
,,xF00C,history battery charge level Today Minus 6,,R,,AH,
184+
,,xF00D,history battery charge level Today Minus 7,,R,,AH,
185+
,,,,,,,,
186+
,,xF00E,History battery discharge level Today Minus 1,,R,,AH,
187+
,,xF00F,History battery discharge level Today Minus 2,,R,,AH,
188+
,,xF010,History battery discharge level Today Minus 3,,R,,AH,
189+
,,xF011,History battery discharge level Today Minus 4,,R,,AH,
190+
,,xF012,History battery discharge level Today Minus 5,,R,,AH,
191+
,,xF013,History battery discharge level Today Minus 6,,R,,AH,
192+
,,xF014,History battery discharge level Today Minus 7,,R,,AH,
193+
,,,,,,,,
194+
,,xF015,history mains charge level Today Minus 1,,R,,AH,
195+
,,xF016,history mains charge level Today Minus 2,,R,,AH,
196+
,,xF017,history mains charge level Today Minus 3,,R,,AH,
197+
,,xF018,history mains charge level Today Minus 4,,R,,AH,
198+
,,xF019,history mains charge level Today Minus 5,,R,,AH,
199+
,,xF01A,history mains charge level Today Minus 6,,R,,AH,
200+
,,xF01B,history mains charge level Today Minus 7,,R,,AH,
201+
,,,,,,,,
202+
,,xF01C,history data of power consumption by load today minus 1,,R,,0.1kwh,
203+
,,xF01D,history power consumption by load today minus 2,,R,,0.1kwh,
204+
,,xF01E,history power consumption by load today minus 3,,R,,0.1kwh,
205+
,,xF01F,history power consumption by load today minus 4,,R,,0.1kwh,
206+
,,xF020,history power consumption by load today minus 5,,R,,0.1kwh,
207+
,,xF021,history power consumption by load today minus 6,,R,,0.1kwh,
208+
,,xF022,history power consumption by load today minus 7,,R,,0.1kwh,
209+
,,,,,,,,
210+
,,xF023,History power consumption by load from mains today minus 1,,R,,0.1kwh,
211+
,,xF024,History power consumption by load from mains today minus 2,,R,,0.1kwh,
212+
,,xF025,History power consumption by load from mains today minus 3,,R,,0.1kwh,
213+
,,xF026,History power consumption by load from mains today minus 4,,R,,0.1kwh,
214+
,,xF027,History power consumption by load from mains today minus 5,,R,,0.1kwh,
215+
,,xF028,History power consumption by load from mains today minus 6,,R,,0.1kwh,
216+
,,xF029,History power consumption by load from mains today minus 7,,R,,0.1kwh,
217+
,,,,,,,,
218+
,,,,,,,,
219+
,,xF02D,Battery charge AH of the day,,R,,AH,
220+
,,xF02E,Battery discharge AH of the day,,R,,AH,
221+
,,xF02F,PV power generation of the day,,R,,0.1kwh,
222+
,,xF030,Load power consumption of the day,,R,,0.1kwh,
223+
,,xF031,Total running days,,R,,day,
224+
,,xF032,"Total number of battery
225+
overdischarge",,R,,,
226+
,,,,,,,,
227+
,,xF033,Total number of battery full charge,,R,,,
228+
,UINT,xF034~xF035,Accumulated battery charge AH,,R,,AH,
229+
,UINT,xF036~xF037,Accumulated battery discharge AH,,R,,AH,
230+
,UINT,xF038~xF039,Accumulated PV power generation,,R,,0.1kWh,
231+
,,xF03A,Accumulated power consumption of load,,R,,0.1kWh,
232+
,,xF03C,Mains charge level of today,,R,,AH,
233+
,,xF03D,Power consumption by load from mains of today,,R,,0.1kWh,
234+
,,xF03E,Inverter working hours of today,,R,,min,
235+
,,xF03F,Bypass working hours of today,,R,,min,
236+
,UINT,xF040~xF041,Power on time,UINT48 � TODO,R,,,
237+
,UINT,xF043~xF044,"Last equalizing charge completion
238+
time",UINT48 � TODO,R,,,
239+
,UINT,xF046~xF047,Accumulated charge level by mains,,R,,0.1kWh,
240+
,UINT,xF048~xF048,Accumulated power consumption by load from mains,,R,,0.1kWh,
241+
,,xF04A,Accumulated working hours of inverter,,R,,h,
242+
,,xF04B,Accumulated working hours of bypass,,R,,h,
243+
,,,,,,,,
244+
,,,,,,,,
245+
,ASCII,xF800~xF80F,FaultHistoryRecord00,,,,,
246+
,ASCII,xF810~xF81F,FaultHistoryRecord01,,,,,
247+
,ASCII,xF820~xF82F,FaultHistoryRecord02,,,,,
248+
,ASCII,xF830~xF83F,FaultHistoryRecord03,,,,,
249+
,ASCII,xF840~xF84F,FaultHistoryRecord04,,,,,
250+
,ASCII,xF850~xF85F,FaultHistoryRecord05,,,,,
251+
,ASCII,xF860~xF86F,FaultHistoryRecord06,,,,,
252+
,ASCII,xF870~xF87F,FaultHistoryRecord07,,,,,
253+
,ASCII,xF880~xF88F,FaultHistoryRecord08,,,,,
254+
,ASCII,xF890~xF89F,FaultHistoryRecord09,,,,,
255+
,ASCII,xF8A0~xF8AF,FaultHistoryRecord10,,,,,
256+
,ASCII,xF8B0~xF8BF,FaultHistoryRecord11,,,,,
257+
,ASCII,xF8C0~xF8CF,FaultHistoryRecord12,,,,,
258+
,ASCII,xF8D0~xF8DF,FaultHistoryRecord13,,,,,
259+
,ASCII,xF8E0~xF8EF,FaultHistoryRecord14,,,,,
260+
,ASCII,xF8F0~xF8FF,FaultHistoryRecord15,,,,,
261+
,,,,,,,,
262+
,,0x0238,MGrid phase-B current,,R,,0.1A,
263+
,,0x0239,MGrid phase-C current,,R,,0.1A,
264+
,BYTE,0xF02C,MStats GenerateEnergyToGridTday,,R,,0.1kWh,

protocols/srne/srne_v1.7.json

+5
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,5 @@
1+
{
2+
"transport" : "modbus_rtu",
3+
"send_holding_register": true,
4+
"send_input_register" : false