Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

VBat conductor shorted to ground on PCB #14

Open
schofiel opened this issue Jan 28, 2024 · 1 comment
Open

VBat conductor shorted to ground on PCB #14

schofiel opened this issue Jan 28, 2024 · 1 comment

Comments

@schofiel
Copy link

The VBat conductor between the Sparkfun TOL 10617 battery positive pin and the BAT/BAT 2 inputs to the MAX8903A charge management IC U2 (pins 21 & 20) is shorted to ground on the PCB by a flood-filled polygon zone. This is on the top copper layer. The design rule checker does not mark the intersection of the polygon with the track as a problem.

The net result is that U2 (MAX8903A) fails to regulate properly and the board fails to operate (dead short/no voltage). With the battery pack connected, the pack delivers peak current (3x 5A) to ground, with the associated fire risk due to battery failure.

An image of the polygon:

VBat Polygon

An image of the resulting top copper gerber:

VBat Polygon on Gerber

The work-around is a careful scalpel cut along the edge of the track to separate the polygon from ground.

@schofiel
Copy link
Author

Should note that this is for the V2 board version.