IoT Edge error: 417 -- The device's deployment configuration is not set #50665

Closed
epomatti opened this issue Mar 22, 2020 · 2 comments
Closed

Comments

@epomatti
Copy link

epomatti commented Mar 22, 2020

While following the quickstart tutorial I ran into this error message on the IoT Edge:

417 -- The device's deployment configuration is not set

The message was there since the device was created, and I am unable to deploy modules to the device.

I tried restarting the service but it had no effect.

image

Update - I'm getting the following error when running iotedge check.

From this document:

Until you deploy your first module to IoT Edge on your device, the $edgeHub system module will not be deployed to the device. As a result, the automated check will return an error for the Edge Hub can bind to ports on host connectivity check. This error can be ignored unless it occurs after deploying a module to the device.

azureuser@EdgeVM:~$ sudo iotedge check
Configuration checks
--------------------
√ config.yaml is well-formed - OK
√ config.yaml has well-formed connection string - OK
√ container engine is installed and functional - OK
‼ config.yaml has correct hostname - Warning
    config.yaml has hostname EdgeVM which does not comply with RFC 1035.
    
    - Hostname must be between 1 and 255 octets inclusive.
    - Each label in the hostname (component separated by ".") must be between 1 and 63 octets inclusive.
    - Each label must start with an ASCII alphabet character (a-z), end with an ASCII alphanumeric character (a-z, 0-9), and must contain only ASCII alphanumeric characters or hyphens (a-z, 0-9, "-").
    
    Not complying with RFC 1035 may cause errors during the TLS handshake with modules and downstream devices.
√ config.yaml has correct URIs for daemon mgmt endpoint - OK
‼ latest security daemon - Warning
    Installed IoT Edge daemon has version 1.0.8 but 1.0.9 is the latest stable version available.
    Please see https://aka.ms/iotedge-update-runtime for update instructions.
√ host time is close to real time - OK
√ container time is close to host time - OK
‼ DNS server - Warning
    Container engine is not configured with DNS server setting, which may impact connectivity to IoT Hub.
    Please see https://aka.ms/iotedge-prod-checklist-dns for best practices.
    You can ignore this warning if you are setting DNS server per module in the Edge deployment.
‼ production readiness: certificates - Warning
    Device is using self-signed, automatically generated certs.
    Please see https://aka.ms/iotedge-prod-checklist-certs for best practices.
√ production readiness: certificates expiry - OK
√ production readiness: container engine - OK
‼ production readiness: logs policy - Warning
    Container engine is not configured to rotate module logs which may cause it run out of disk space.
    Please see https://aka.ms/iotedge-prod-checklist-logs for best practices.
    You can ignore this warning if you are setting log policy per module in the Edge deployment.

Connectivity checks
-------------------
√ host can connect to and perform TLS handshake with IoT Hub AMQP port - OK
√ host can connect to and perform TLS handshake with IoT Hub HTTPS / WebSockets port - OK
√ host can connect to and perform TLS handshake with IoT Hub MQTT port - OK
√ container on the default network can connect to IoT Hub AMQP port - OK
√ container on the default network can connect to IoT Hub HTTPS / WebSockets port - OK
√ container on the default network can connect to IoT Hub MQTT port - OK
√ container on the IoT Edge module network can connect to IoT Hub AMQP port - OK
√ container on the IoT Edge module network can connect to IoT Hub HTTPS / WebSockets port - OK
√ container on the IoT Edge module network can connect to IoT Hub MQTT port - OK
× Edge Hub can bind to ports on host - Error
    Could not check current state of Edge Hub container

17 check(s) succeeded.
5 check(s) raised warnings. Re-run with --verbose for more details.
1 check(s) raised errors. Re-run with --verbose for more details.


Document Details

Do not edit this section. It is required for docs.microsoft.com ➟ GitHub issue linking.

@epomatti
Copy link
Author

Ok I'm not sure what I did wrong but I had to add the module again. Maybe I missed something.

@femsulu
Copy link
Member

femsulu commented Mar 22, 2020

thanks for the update @evandropomatti. Happy this is resolved for you.

@femsulu femsulu closed this as completed Mar 22, 2020