Coil:Cooling:DX:*, Coil:Heating:DX:*, Coil:WaterHeating:*: new "Crankcase Heater Capacity Function of Temperature Curve Name" field
Coil:Cooling:DX:TwoSpeed, Coil:Cooling:DX:VariableSpeedCoil:Heating:DX:VariableSpeed: add fields "High Speed 2017 Rated Evaporator Fan Power Per Volume Flow Rate", "High Speed 2023 Rated Evaporator Fan Power Per Volume Flow Rate", "Low Speed 2017 Rated Evaporator Fan Power Per Volume Flow Rate", and "Low Speed 2023 Rated Evaporator Fan Power Per Volume Flow Rate"
AirLoopHVAC:UnitarySystem, AirLoopHVAC:UnitaryHeatPump :WaterToAir (not wrapped), ZoneHVAC:WaterToAirHeatPump: remove a handful of fields
HVACTemplate:Zone:WaterToAirHeatPump (not wrapped): rename "Heat Pump Time Constant" to "Latent Capacity Time Constant" and remove "Fraction of On-Cycle Power Use"
ZoneHVAC:EvaporativeCoolerUnit (not wrapped): add field "Shut Off Relative Humidity"
Coil:Heating:Fuel, Coil:Heating:Gas:MultiStage, Coil:Heating:Desuperheater: rename "Parasitic Electric Load" to "On Cycle Parasitic Electric Load" and "Parasitic Fuel Load" to "Off Cycle Parasitic Fuel Load"
Enhancement Request
Once v23.2-IOFreeze is released, we should update to it.
Detailed Description
https://github.com/NREL/EnergyPlus/blob/develop/src/Transition/InputRulesFiles/Rules23-1-0-to-23-2-0.md
https://github.com/NREL/EnergyPlus/blob/develop/src/Transition/OutputRulesFiles/OutputChanges23-1-0-to-23-2-0.md
Major changes
Fuel Type enum changes (
OtherEquipment
,Exterior:FuelEquipment
,ZoneHVAC:HybridUnitaryHVAC
, etc.)v23.2.0-IOFreeze: Coil and Unitary systems changes #4958
Coil:Cooling:DX:*
,Coil:Heating:DX:*
,Coil:WaterHeating:*
: new "Crankcase Heater Capacity Function of Temperature Curve Name" fieldCoil:Cooling:DX:TwoSpeed
,Coil:Cooling:DX:VariableSpeed
Coil:Heating:DX:VariableSpeed
: add fields "High Speed 2017 Rated Evaporator Fan Power Per Volume Flow Rate", "High Speed 2023 Rated Evaporator Fan Power Per Volume Flow Rate", "Low Speed 2017 Rated Evaporator Fan Power Per Volume Flow Rate", and "Low Speed 2023 Rated Evaporator Fan Power Per Volume Flow Rate"AirLoopHVAC:UnitarySystem
,AirLoopHVAC:UnitaryHeatPump :WaterToAir
(not wrapped),ZoneHVAC:WaterToAirHeatPump
: remove a handful of fieldsCoil:Cooling:DX:VariableSpeed
,Coil:Cooling:WaterToAirHeatPump:VariableSpeedEquationFit
: add fields "Maximum Cycling Rate", "Latent Capacity Time Constant", "Fan Delay Time"Coil:Cooling:WaterToAirHeatPump:ParameterEstimation
(not wrapped),Coil:Cooling:WaterToAirHeatPump:EquationFit
: add fields "Part Load Fraction Correlation Curve Name", "Maximum Cycling Rate", "Latent Capacity Time Constant", "Fan Delay Time"Coil:Heating:WaterToAirHeatPump:ParameterEstimation
(not wrapped),Coil:Heating:WaterToAirHeatPump:EquationFit
: add field "Part Load Fraction Correlation Curve Name"HeatPump:PlantLoop:EIR:Cooling
,HeatPump:PlantLoop:EIR:Heating
: required field changes, and some new fieldsNew additions
ZoneEarthtube
: two new fields;ZoneEarthtube:Parameters
: new objectSpaceHVAC:EquipmentConnections
,SpaceHVAC:ZoneEquipmentSplitter
,SpaceHVAC:ZoneEquipmentMixer
: new objectDistrictHeating:Steam
: new objectDistrictHeating:Steam
and renameDistrictHeating
toDistrictHeatingWater
#4972PlantEquipmentOperation:ChillerHeaterChangeover
: new objectMinor stuff
DistrictHeating
toDistrictHeating:Water
: new object name in forward translationSurfaceProperty:LocalEnvironment
: change "External Shading Fraction Schedule Name" to "Sunlit Fraction Schedule Name"HVACTemplate:Zone:WaterToAirHeatPump
(not wrapped): rename "Heat Pump Time Constant" to "Latent Capacity Time Constant" and remove "Fraction of On-Cycle Power Use"ZoneHVAC:EvaporativeCoolerUnit
(not wrapped): add field "Shut Off Relative Humidity"ZoneHVAC:WaterToAirHeatPump
,ZoneHVAC:TerminalUnit:VariableRefrigerantFlow
: add fields "Design Specification Multispeed Object Type" and "Design Specification Multispeed Object Name"Coil:Heating:Fuel
,Coil:Heating:Gas:MultiStage
,Coil:Heating:Desuperheater
: rename "Parasitic Electric Load" to "On Cycle Parasitic Electric Load" and "Parasitic Fuel Load" to "Off Cycle Parasitic Fuel Load"Boiler:HotWater
: rename "Parasitic Electric Load" to "On Cycle Parasitic Electric Load" and add "Off Cycle Parasitic Fuel Load"Controller:OutdoorAir
: new field "Economizer Operation Staging"LoadProfile:Plant
: new fields "Plant Loop Fluid Type", "Degree of SubCooling", "Degree of Loop SubCooling"EnvironmentalImpactFactors
: update field namesOther
ConstructionProperty:InternalHeatSource
: remove\note required-field
lineConstruction:ComplexFenestrationState
: fix "Absoptance" spelling in fieldsThe text was updated successfully, but these errors were encountered: