The MIMO master clock setting and the XB-200 reference clock setting only do writes to register 39 of the si5338 - they do not do read/modify/write calls. Therefore, an XB-200 enabled bladeRF could never also be a MIMO master which is just silly.
The text was updated successfully, but these errors were encountered:
The MIMO master clock setting and the XB-200 reference clock setting only do writes to register 39 of the si5338 - they do not do read/modify/write calls. Therefore, an XB-200 enabled bladeRF could never also be a MIMO master which is just silly.