Notifications
You must be signed in to change notification settings - Fork 68
/
3428.xml
327 lines (322 loc) · 13 KB
/
3428.xml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
<?xml version="1.0" encoding="UTF-8"?>
<!-- BSD-3 Clause License
Copyright 2023 uCIFI Alliance
Redistribution and use in source and binary forms, with or without
modification, are permitted provided that the following conditions
are met:
1. Redistributions of source code must retain the above copyright
notice, this list of conditions and the following disclaimer.
2. Redistributions in binary form must reproduce the above copyright
notice, this list of conditions and the following disclaimer in the
documentation and/or other materials provided with the distribution.
3. Neither the name of the copyright holder nor the names of its
contributors may be used to endorse or promote products derived
from this software without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
"AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT,
INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING,
BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN
ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
-->
<LWM2M xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://www.openmobilealliance.org/tech/profiles/LWM2M.xsd">
<Object ObjectType="MODefinition">
<Name>Air quality</Name>
<Description1>The uCIFI air quality sensor reports measurement required to calculate Air Quality Index (AIQ. It also provides resources for average calculation as per the IQ index calculation.</Description1>
<ObjectID>3428</ObjectID>
<ObjectURN>urn:oma:lwm2m:ext:3428:2.0</ObjectURN>
<LWM2MVersion>1.0</LWM2MVersion>
<ObjectVersion>2.0</ObjectVersion>
<MultipleInstances>Multiple</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Resources>
<Item ID="1">
<Name>PM10</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>ug/m3</Units>
<Description>Level of PM10 measured by the air quality sensor.</Description>
</Item>
<Item ID="2">
<Name>PM10 24 hour average</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>ug/m3</Units>
<Description>Average level of PM10 measured by the sensor during the last 24 hours.</Description>
</Item>
<Item ID="3">
<Name>PM2.5</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>ug/m3</Units>
<Description>Level of PM2.5 measured by the air quality sensor.</Description>
</Item>
<Item ID="4">
<Name>PM2.5 24 hour average</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>ug/m3</Units>
<Description>Average level of PM2.5 measured by the sensor during the last 24 hours.</Description>
</Item>
<Item ID="5">
<Name>PM1</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>ug/m3</Units>
<Description>Level of PM1 measured by the air quality sensor.</Description>
</Item>
<Item ID="6">
<Name>PM1 24 hour average</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>ug/m3</Units>
<Description>Average level of PM1 measured by the sensor during the last 24 hours.</Description>
</Item>
<Item ID="7">
<Name>CO</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>ppm</Units>
<Description>Level of carbon monoxide measured by the air quality sensor.</Description>
</Item>
<Item ID="8">
<Name>CO 8 hour average</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>ppm</Units>
<Description>Average level of carbon monoxide measured by the sensor during the last 8 hours.</Description>
</Item>
<Item ID="9">
<Name>SO2</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>ppm</Units>
<Description>Level of sulfur dioxide measured by the air quality sensor.</Description>
</Item>
<Item ID="10">
<Name>SO2 1 hour average</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>ppm</Units>
<Description>Average level of sulfur dioxide measured by the sensor during the last 1 hour.</Description>
</Item>
<Item ID="11">
<Name>SO2 24 hour average</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>ppm</Units>
<Description>Average level of sulfur dioxide measured by the sensor during the last 24 hours.</Description>
</Item>
<Item ID="12">
<Name>O3</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>ppm</Units>
<Description>Level of ozone measured by the air quality sensor.</Description>
</Item>
<Item ID="13">
<Name>O3 1 hour average</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>ppm</Units>
<Description>Average level of ozone measured by the sensor during the last 1 hour.</Description>
</Item>
<Item ID="14">
<Name>O3 8 hour average</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>ppm</Units>
<Description>Average level of ozone measured by the sensor during the last 8 hour.</Description>
</Item>
<Item ID="15">
<Name>NO2</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>ppm</Units>
<Description>Level of nitrogen dioxide measured by the air quality sensor.</Description>
</Item>
<Item ID="16">
<Name>NO2 1 hour average</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>ppm</Units>
<Description>Average level of nitrogen dioxide measured by the sensor during the last 1 hour.</Description>
</Item>
<Item ID="17">
<Name>CO2</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>ppm</Units>
<Description>Level of carbon dioxide measured by the air quality sensor.</Description>
</Item>
<Item ID="18">
<Name>CO2 1 hour average</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>ppm</Units>
<Description>Average level of carbon dioxide measured by the sensor during the last 1 hour.</Description>
</Item>
<Item ID="19">
<Name>NO</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>ppm</Units>
<Description>Level of nitric oxide measured by the air quality sensor.</Description>
</Item>
<Item ID="20">
<Name>NO 1 hour average</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>ppm</Units>
<Description>Average level of nitric oxide measured by the sensor during the last 1 hour.</Description>
</Item>
<Item ID="21">
<Name>H2S</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>ppm</Units>
<Description>Level of hydrogen sulfid measured by the air quality sensor.</Description>
</Item>
<Item ID="22">
<Name>H2S 1 hour average</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>ppm</Units>
<Description>Average level of hydrogen sulfid measured by the sensor during the last 1 hour.</Description>
</Item>
<Item ID="23">
<Name>VOC</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>ppm</Units>
<Description>Level of Volatile Organic Compounds measured by the air quality sensor.</Description>
</Item>
<Item ID="24">
<Name>VOC 1 hour average</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>ppm</Units>
<Description>Average level of Volatile Organic Compounds measured by the sensor during the last 1 hour.</Description>
</Item>
<Item ID="5518">
<Name>Timestamp</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Time</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>The timestamp of when the measurement was performed.</Description>
</Item>
<Item ID="6050">
<Name>Fractional Timestamp</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration>0..1</RangeEnumeration>
<Units>s</Units>
<Description>Fractional part of the timestamp when sub-second precision is used (e.g., 0.23 for 230 ms).</Description>
</Item>
<Item ID="6042">
<Name>Measurement Quality Indicator</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Integer</Type>
<RangeEnumeration>0..23</RangeEnumeration>
<Units></Units>
<Description>Measurement quality indicator reported by a smart sensor. 0: UNCHECKED No quality checks were done because they do not exist or can not be applied. 1: REJECTED WITH CERTAINTY The measured value is invalid. 2: REJECTED WITH PROBABILITY The measured value is likely invalid. 3: ACCEPTED BUT SUSPICIOUS The measured value is likely OK. 4: ACCEPTED The measured value is OK. 5-15: Reserved for future extensions. 16-23: Vendor specific measurement quality.</Description>
</Item>
<Item ID="6049">
<Name>Measurement Quality Level</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Integer</Type>
<RangeEnumeration>0..100</RangeEnumeration>
<Units></Units>
<Description>Measurement quality level reported by a smart sensor. Quality level 100 means that the measurement has fully passed quality check algorithms. Smaller quality levels mean that quality has decreased and the measurement has only partially passed quality check algorithms. The smaller the quality level, the more caution should be used by the application when using the measurement. When the quality level is 0 it means that the measurement should certainly be rejected.</Description>
</Item>
</Resources>
<Description2></Description2>
</Object>
</LWM2M>