Describe the bug
Hello,
i am experiencing some very strange startup behavour on my MH-30 in v2.22.
There are 3 startup oprions to choose from, but they do NOT work as expected.
Expected behaviour:
Option 0: No heating after boot.
Option S: Start heating after boot to set Temp.
Shut heating off when moved after heating manually?
Option Z: Start heating after boot to standby Temp, which is nowhere to configure, yet. Stop heating when device is moved. (Has to be be: heat up to set temp when moved to make any sense). Do NOT shut heating off when moved!
Option R: Do not start heating after boot, when device is moved heat up to set temp. Do not shut heating off, when moved!
Current behaviour for
Option 0: No heating after boot. Does nearly what it is supposed to do. Moving the device stopps heating (why?).
Option S, Z, R: Start heating after boot up to the one and only set temp. Moving the device stopps heating, even after restarting the heating process after the initial boot. There is no other temperature selected between the options, nor is such a value anywhere available to configure.
The lock function for boost only has currently no real value. It is expected to lock the current boost temperature, which it does not accomplish.
To Reproduce
Install v2.22 and See what the startup oprions do in Real Life.
Expected behavior
See above.
Details of your device:
Device: MH-30
Release: 2.22
Power adapter being used: 100W PD
If this is an accelerometer related issue, please include its model number here: Version 2 of MH-30
Additional context
You are doing great work. The new heating Option for reflow is awesome and a thing i wanted from the beginning. Now my heater has a real value for me. Thank you soo much!
The text was updated successfully, but these errors were encountered:
Describe the bug
Hello,
i am experiencing some very strange startup behavour on my MH-30 in v2.22.
There are 3 startup oprions to choose from, but they do NOT work as expected.
Expected behaviour:
Option 0: No heating after boot.
Option S: Start heating after boot to set Temp.
Shut heating off when moved after heating manually?
Option Z: Start heating after boot to standby Temp, which is nowhere to configure, yet. Stop heating when device is moved. (Has to be be: heat up to set temp when moved to make any sense). Do NOT shut heating off when moved!
Option R: Do not start heating after boot, when device is moved heat up to set temp. Do not shut heating off, when moved!
Current behaviour for
Option 0: No heating after boot. Does nearly what it is supposed to do. Moving the device stopps heating (why?).
Option S, Z, R: Start heating after boot up to the one and only set temp. Moving the device stopps heating, even after restarting the heating process after the initial boot. There is no other temperature selected between the options, nor is such a value anywhere available to configure.
The lock function for boost only has currently no real value. It is expected to lock the current boost temperature, which it does not accomplish.
To Reproduce
Install v2.22 and See what the startup oprions do in Real Life.
Expected behavior
See above.
Details of your device:
Additional context
You are doing great work. The new heating Option for reflow is awesome and a thing i wanted from the beginning. Now my heater has a real value for me. Thank you soo much!
The text was updated successfully, but these errors were encountered: