Skip to content

Latest commit

 

History

History
1364 lines (1127 loc) · 53.6 KB

README.md

File metadata and controls

1364 lines (1127 loc) · 53.6 KB

FIWARE Banner

FIWARE Core Context Management License: MIT NGSI v1 Support badge
Documentation

This tutorial is an introduction to FIWARE STH-Comet - a generic enabler which is used to retrieve trend data from a MongoDB database. The tutorial activates the IoT sensors connected in the previous tutorial and persists measurements from those sensors into a database and retrieves time-based aggregations of that data.

The tutorial uses cUrl commands throughout, but is also available as Postman documentation

Run in Postman

  • このチュートリアルは日本語でもご覧いただけます。

Contents

Details

Querying Time Series Data (MongoDB)

"The "moment" has no yesterday or tomorrow. It is not the result of thought and therefore has no time."

— Bruce Lee

Within the FIWARE platform, historical context data can be persisted to a database (such as MongoDB) using a combination of the Orion Context Broker and the Cygnus generic enabler. This results in a series of data points being written to the database of your choice. Each time-stamped data point represents the state of context entities at a given moment in time. The individual data points are relatively meaningless on their own, it is only through combining a series data points that meaningful statistics such as maxima, minima and trends can be observed.

The creation and analysis of trend data is a common requirement of context-driven systems - therefore the FIWARE platform offers a generic enabler (STH-Comet) specifically to deal with the issue of persisting and interpreting time series data persisted into MongoDB. STH-Comet itself can be used in two modes:

  • In minimal mode, STH-Comet is responsible for both data collection and interpreting the data when requested
  • In formal mode, the collection of data is delegated to Cygnus, STH-Comet merely reads from an existing database.

Of the two modes of operation, the formal mode is more flexible, but minimal mode is simpler and easier to set-up. The key differences between the two are summarized in the table below:

minimal mode formal mode
Is the system easy to set-up properly? Only one configuration supported - Easy to set up Highly configurable - Complex to set up
Which component is responsible for a data persistence? STH-Comet Cygnus
What is the role of STH-Comet? Reading and writing data Data Read only
What is the role of Cygnus? Not Used Data Write only
Where is the data aggregated? MongoDB database connected to STH-Comet only MongoDB database connected to both Cygnus and STH-Comet
Can the system be configured to use other databases? No Yes
Does the solution scale easily? Does not scale easily - use for simple systems Scales easily - use for complex systems
Can the system cope with high rates of throughput? No - use where throughput is low Yes - use where throughput is high

Analyzing time series data

The appropriate use of time series data analysis will depend on your use case and the reliability of the data measurements you receive. Time series data analysis can be used to answer questions such as:

  • What was the maximum measurement of a device within a given time period?
  • What was the average measurement of a device within a given time period?
  • What was the sum of the measurements sent by a device within a given time period?

It can also be used to reduce the significance of each individual data point to exclude outliers by smoothing.

Device Monitor

For the purpose of this tutorial, a series of dummy IoT devices have been created, which will be attached to the context broker. Details of the architecture and protocol used can be found in the IoT Sensors tutorial. The state of each device can be seen on the UltraLight device monitor web page found at: http://localhost:3000/device/monitor

FIWARE Monitor

Device History

Once STH-Comet has started aggregating data, the historical state of each device can be seen on the device history web page found at: http://localhost:3000/device/history/urn:ngsi-ld:Store:001

Architecture

This application builds on the components and dummy IoT devices created in previous tutorials. It will use three or four FIWARE components depending on the configuration of the system: the Orion Context Broker, the IoT Agent for Ultralight 2.0, STH-Comet and Cygnus.

Therefore the overall architecture will consist of the following elements:

  • Four FIWARE Generic Enablers:
    • The FIWARE Orion Context Broker which will receive requests using NGSI-v2
    • The FIWARE IoT Agent for Ultralight 2.0 which will receive northbound measurements from the dummy IoT devices in Ultralight 2.0 format and convert them to NGSI-v2 requests for the context broker to alter the state of the context entities
    • FIWARE STH-Comet will:
      • interpret time-based data queries
      • subscribe to context changes and persist them into a MongoDB database (minimal mode only)
    • FIWARE Cygnus where it will subscribe to context changes and persist them into a MongoDB database (formal mode only)

:informationsource: Note: Cygnus will only be used if STH-Comet is configured in _formal mode.

  • A MongoDB database:
    • Used by the Orion Context Broker to hold context data information such as data entities, subscriptions and registrations
    • Used by the IoT Agent to hold device information such as device URLs and Keys
    • Used as a data sink to hold time-based historical context data
      • In minimal mode - this is read and populated by STH-Comet
      • In formal mode - this is populated by Cygnus and read by STH-Comet
  • Three Context Providers:
    • The Stock Management Frontend is not used in this tutorial. It does the following:
      • Display store information and allow users to interact with the dummy IoT devices
      • Show which products can be bought at each store
      • Allow users to "buy" products and reduce the stock count.
    • A webserver acting as set of dummy IoT devices using the Ultralight 2.0 protocol running over HTTP.
    • The Context Provider NGSI proxy is not used in this tutorial. It does the following:
      • receive requests using NGSI-v2
      • makes requests to publicly available data sources using their own APIs in a proprietary format
      • returns context data back to the Orion Context Broker in NGSI-v2 format.

Since all interactions between the elements are initiated by HTTP requests, the entities can be containerized and run from exposed ports.

The specific architecture of both the minimal and formal configurations is discussed below.

Prerequisites

Docker and Docker Compose

To keep things simple all components will be run using Docker. Docker is a container technology which allows to different components isolated into their respective environments.

  • To install Docker on Windows follow the instructions here
  • To install Docker on Mac follow the instructions here
  • To install Docker on Linux follow the instructions here

Docker Compose is a tool for defining and running multi-container Docker applications. A series of YAML files are used configure the required services for the application. This means all container services can be brought up in a single command. Docker Compose is installed by default as part of Docker for Windows and Docker for Mac, however Linux users will need to follow the instructions found here

You can check your current Docker and Docker Compose versions using the following commands:

docker-compose -v
docker version

Please ensure that you are using Docker version 18.03 or higher and Docker Compose 1.21 or higher and upgrade if necessary.

Cygwin for Windows

We will start up our services using a simple Bash script. Windows users should download cygwin to provide a command-line functionality similar to a Linux distribution on Windows.

Start Up

Before you start you should ensure that you have obtained or built the necessary Docker images locally. Please clone the repository and create the necessary images by running the commands as shown:

git clone https://github.com/FIWARE/tutorials.Short-Term-History.git
cd tutorials.Short-Term-History

./services create

Thereafter, all services can be initialized from the command-line by running the services Bash script provided within the repository:

./services <command>

Where <command> will vary depending upon the mode we wish to activate. This command will also import seed data from the previous tutorials and provision the dummy IoT sensors on startup.

ℹ️ Note: If you want to clean up and start over again you can do so with the following command:

./services stop

minimal mode (STH-Comet only)

In the minimal configuration, STH-Comet is used to persisting historic context data and also used to make time-based queries. All operations take place on the same port 8666. The MongoDB instance listening on the standard 27017 port is used to hold data the historic context data as well as holding data related to the Orion Context Broker and the IoT Agent. The overall architecture can be seen below:

Database Server Configuration

mongo-db:
    image: mongo:3.6
    hostname: mongo-db
    container_name: db-mongo
    ports:
        - "27017:27017"
    networks:
        - default
    command: --bind_ip_all --smallfiles

STH-Comet Configuration

sth-comet:
    image: fiware/sth-comet
    hostname: sth-comet
    container_name: fiware-sth-comet
    depends_on:
        - mongo-db
    networks:
        - default
    ports:
        - "8666:8666"
    environment:
        - STH_HOST=0.0.0.0
        - STH_PORT=8666
        - DB_PREFIX=sth_
        - DB_URI=mongo-db:27017
        - LOGOPS_LEVEL=DEBUG

The sth-comet container is listening on one port:

  • The Operations for port for STH-Comet - 8666 is where the service will be listening for notifications from the Orion context broker as well as time based query requests from cUrl or Postman

The sth-comet container is driven by environment variables as shown:

Key Value Description
STH_HOST 0.0.0.0 The address where STH-Comet is hosted - within this container it means all IPv4 addresses on the local machine
STH_PORT 8666 Operations Port that STH-Comet listens on, it is also used when subscribing to context data changes
DB_PREFIX sth_ The prefix added to each database entity if none is provided
DB_URI mongo-db:27017 The MongoDB server which STH-Comet will contact to persist historical context data
LOGOPS_LEVEL DEBUG The logging level for STH-Comet

minimal mode - Start up

To start the system using the minimal configuration using STH-Comet only, run the following command:

./services sth-comet

STH-Comet - Checking Service Health

Once STH-Comet is running, you can check the status by making an HTTP request to the exposed STH_PORT port. If the response is blank, this is usually because STH-Comet is not running or is listening on another port.

1️⃣ Request:

curl -X GET \
  'http://localhost:8666/version'

Response:

The response will look similar to the following:

{
    "version": "2.3.0-next"
}

Troubleshooting: What if the response is blank ?

  • To check that a docker container is running try
docker ps

You should see several containers running. If sth-comet or cygnus is not running, you can restart the containers as necessary.

Generating Context Data

For the purpose of this tutorial, we must be monitoring a system where the context is periodically being updated. The dummy IoT Sensors can be used to do this. Open the device monitor page at http://localhost:3000/device/monitor and unlock a Smart Door and switch on a Smart Lamp. This can be done by selecting an appropriate the command from the drop down list and pressing the send button. The stream of measurements coming from the devices can then be seen on the same page:

minimal mode - Subscribing STH-Comet to Context Changes

Once a dynamic context system is up and running, under minimal mode, STH-Comet needs to be informed of changes in context. Therefore we need to set up a subscription in the Orion Context Broker to notify STH-Comet of these changes. The details of the subscription will differ dependent upon the device being monitored and the sampling rate.

STH-Comet - Aggregate Motion Sensor Count Events

The rate of change of the Motion Sensor is driven by events in the real-world. We need to receive every event to be able to aggregate the results.

This is done by making a POST request to the /v2/subscription endpoint of the Orion Context Broker.

  • The fiware-service and fiware-servicepath headers are used to filter the subscription to only listen to measurements from the attached IoT Sensors
  • The idPattern in the request body ensures that STH-Comet will be informed of all Motion Sensor data changes.
  • The notification url must match the configured STH_PORT
  • The attrsFormat=legacy is required since STH-Comet currently only accepts notifications in the older NGSI v1 format.

2️⃣ Request:

curl -iX POST \
  'http://localhost:1026/v2/subscriptions/' \
  -H 'Content-Type: application/json' \
  -H 'fiware-service: openiot' \
  -H 'fiware-servicepath: /' \
  -d '{
  "description": "Notify STH-Comet of all Motion Sensor count changes",
  "subject": {
    "entities": [
      {
        "idPattern": "Motion.*"
      }
    ],
    "condition": {"attrs": ["count"] }
  },
  "notification": {
    "http": {
      "url": "http://sth-comet:8666/notify"
    },
    "attrs": [
      "count"
    ],
    "attrsFormat": "legacy"
  }
}'

STH-Comet - Sample Lamp Luminosity

The luminosity of the Smart Lamp is constantly changing, we only need to sample the values to be able to work out relevant statistics such as minimum and maximum values and rates of change.

This is done by making a POST request to the /v2/subscription endpoint of the Orion Context Broker and including the throttling attribute in the request body.

  • The fiware-service and fiware-servicepath headers are used to filter the subscription to only listen to measurements from the attached IoT Sensors
  • The idPattern in the request body ensures that STH-Comet will be informed of all Smart Lamp data changes only
  • The notification url must match the configured STH_PORT
  • The attrsFormat=legacy is required since STH-Comet currently only accepts notifications in the older NGSI v1 format.
  • The throttling value defines the rate that changes are sampled.

ℹ️ Note: Be careful when throttling subscriptions as sequential updates will not be persisted as expected.

For example if an UltraLight device sends the measurement t|20|l|1200 it will be a single atomic commit and both attributes will be included the notification to STH-Comet however is a device sends t|20#l|1200 this will be treated as two atomic commits - a notification will be sent for the first change in t, but the second change in l will be ignored as the entity has been recently updated within the sampling period.

3️⃣ Request:

curl -iX POST \
  'http://localhost:1026/v2/subscriptions/' \
  -H 'Content-Type: application/json' \
  -H 'fiware-service: openiot' \
  -H 'fiware-servicepath: /' \
  -d '{
  "description": "Notify Cygnus to sample Lamp luminosity every five seconds",
  "subject": {
    "entities": [
      {
        "idPattern": "Lamp.*"
      }
    ],
    "condition": {
      "attrs": [
        "luminosity"
      ]
    }
  },
  "notification": {
    "http": {
      "url": "http://sth-comet:8666/notify"
    },
    "attrs": [
      "luminosity"
    ]
  },
  "throttling": 5
}'

Time Series Data Queries

The queries in this section assume you have already connected STH-Comet using either minimal mode or formal mode and have collected some data.

Prerequisites

STH-Comet will only be able to retrieve time series data if sufficient data points have already been aggregated within the system. Please ensure that the Smart Door has been unlocked and the Smart Lamp has been switched on and the subscriptions have been registered. Data should be collected for at least a minute before the tutorial.

Check that Subscriptions Exist

You can note that the fiware-service and fiware-servicepath headers must be set in the query and match the values used when setting up the subscription

4️⃣ Request:

curl -X GET \
  'http://localhost:1026/v2/subscriptions/' \
  -H 'fiware-service: openiot' \
  -H 'fiware-servicepath: /'
}'

Response:

[
    {
        "id": "5b39e3c11615e2e55a8df103",
        "description": "Notify STH-Comet of all Motion Sensor count changes",
        "status": "active",
        "subject": { ...ETC },
        "notification": {
            "timesSent": 6,
            "lastNotification": "2018-07-02T08:36:04.00Z",
            "attrs": ["count"],
            "attrsFormat": "legacy",
            "http": { "url": "http://sth-comet:8666/notify" },
            "lastSuccess": "2018-07-02T08:36:04.00Z"
        }
    },
    {
        "id": "5b39e3c31615e2e55a8df104",
        "description": "Notify STH-Comet to sample Lamp changes every five seconds",
        "status": "active",
        "subject": { ...ETC },
        "notification": {
            "timesSent": 4,
            "lastNotification": "2018-07-02T08:36:00.00Z",
            "attrs": ["luminosity"],
            "attrsFormat": "legacy",
            "http": { "url": "http://sth-comet:8666/notify" },
            "lastSuccess": "2018-07-02T08:36:01.00Z"
        },
        "throttling": 5
    }
]

The result should not be empty. Within the notification section of the response, you can see several additional attributes which describe the health of each subscription.

If the criteria of the subscription have been met, timesSent should be greater than 0. A zero value would indicate that the subject of the subscription is incorrect or the subscription has created with the wrong fiware-service-path or fiware-service header

The lastNotification should be a recent timestamp - if this is not the case, then the devices are not regularly sending data. Remember to unlock the Smart Door and switch on the Smart Lamp

The lastSuccess should match the lastNotification date - if this is not the case then Cygnus or STH Comet are not receiving the subscription properly. Check that the hostname and port are correct.

Finally, check that the status of the subscription is active - an expired subscription will not fire.

Offsets, Limits and Pagination

List the first N sampled values

This example shows the first 3 sampled luminosity values from Lamp:001.

To obtain the short term history of a context entity attribute, send a GET request to ../STH/v1/contextEntities/type/<Entity>/id/<entity-id>/attributes/<attribute>

the hLimit parameter restricts the result to N values. hOffset=0 will start with the first value.

5️⃣ Request:

curl -X GET \
  'http://localhost:8666/STH/v1/contextEntities/type/Lamp/id/Lamp:001/attributes/luminosity?hLimit=3&hOffset=0' \
  -H 'fiware-service: openiot' \
  -H 'fiware-servicepath: /'

Response:

{
    "contextResponses": [
        {
            "contextElement": {
                "attributes": [
                    {
                        "name": "luminosity",
                        "values": [
                            {
                                "recvTime": "2018-06-21T12:20:19.841Z",
                                "attrType": "Integer",
                                "attrValue": "1972"
                            },
                            {
                                "recvTime": "2018-06-21T12:20:20.819Z",
                                "attrType": "Integer",
                                "attrValue": "1982"
                            },
                            {
                                "recvTime": "2018-06-21T12:20:29.923Z",
                                "attrType": "Integer",
                                "attrValue": "1937"
                            }
                        ]
                    }
                ],
                "id": "Lamp:001",
                "isPattern": false,
                "type": "Lamp"
            },
            "statusCode": {
                "code": "200",
                "reasonPhrase": "OK"
            }
        }
    ]
}

List N sampled values at an Offset

This example shows the fourth, fifth and sixth sampled count values from Motion:001.

To obtain the short term history of a context entity attribute, send a GET request to ../STH/v1/contextEntities/type/<Entity>/id/<entity-id>/attributes/<attribute>

the hLimit parameter restricts the result to N values. Setting hOffset to a non-zero value will start from the Nth measurement

6️⃣ Request:

curl -X GET \
  'http://localhost:8666/STH/v1/contextEntities/type/Motion/id/Motion:001/attributes/count?hLimit=3&hOffset=3' \
  -H 'fiware-service: openiot' \
  -H 'fiware-servicepath: /'

Response:

{
    "contextResponses": [
        {
            "contextElement": {
                "attributes": [
                    {
                        "name": "count",
                        "values": [
                            {
                                "recvTime": "2018-06-21T12:37:00.358Z",
                                "attrType": "Integer",
                                "attrValue": "1"
                            },
                            {
                                "recvTime": "2018-06-21T12:37:01.368Z",
                                "attrType": "Integer",
                                "attrValue": "0"
                            },
                            {
                                "recvTime": "2018-06-21T12:37:07.461Z",
                                "attrType": "Integer",
                                "attrValue": "1"
                            }
                        ]
                    }
                ],
                "id": "Motion:001",
                "isPattern": false,
                "type": "Motion"
            },
            "statusCode": {
                "code": "200",
                "reasonPhrase": "OK"
            }
        }
    ]
}

List the latest N sampled values

This example shows latest three sampled count values from Motion:001.

To obtain the short term history of a context entity attribute, send a GET request to ../STH/v1/contextEntities/type/<Entity>/id/<entity-id>/attributes/<attribute>

If the lastN parameter is set, the result will return the N latest measurements only.

7️⃣ Request:

curl -X GET \
  'http://localhost:8666/STH/v1/contextEntities/type/Motion/id/Motion:001/attributes/count?lastN=3' \
  -H 'fiware-service: openiot' \
  -H 'fiware-servicepath: /'

Response:

{
    "contextResponses": [
        {
            "contextElement": {
                "attributes": [
                    {
                        "name": "count",
                        "values": [
                            {
                                "recvTime": "2018-06-21T12:47:28.377Z",
                                "attrType": "Integer",
                                "attrValue": "0"
                            },
                            {
                                "recvTime": "2018-06-21T12:48:08.930Z",
                                "attrType": "Integer",
                                "attrValue": "1"
                            },
                            {
                                "recvTime": "2018-06-21T12:48:13.989Z",
                                "attrType": "Integer",
                                "attrValue": "0"
                            }
                        ]
                    }
                ],
                "id": "Motion:001",
                "isPattern": false,
                "type": "Motion"
            },
            "statusCode": {
                "code": "200",
                "reasonPhrase": "OK"
            }
        }
    ]
}

Time Period Queries

List the sum of values over a time period

This example shows total count values from Motion:001 over each minute

To obtain the short term history of a context entity attribute, send a GET request to ../STH/v1/contextEntities/type/<Entity>/id/<entity-id>/attributes/<attribute>

The aggrMethod parameter determines the type of aggregation to perform over the time series, the aggrPeriod is one of second, minute, hour or day.

Always select the most appropriate time period based on the frequency of your data collection. minute has been selected because the Motion:001 is firing a few times within each minute.

8️⃣ Request:

curl -X GET \
  'http://localhost:8666/STH/v1/contextEntities/type/Motion/id/Motion:001/attributes/count?aggrMethod=sum&aggrPeriod=minute' \
  -H 'fiware-service: openiot' \
  -H 'fiware-servicepath: /'

Response:

{
    "contextResponses": [
        {
            "contextElement": {
                "attributes": [
                    {
                        "name": "count",
                        "values": [
                            {
                                "_id": {
                                    "attrName": "count",
                                    "origin": "2018-06-21T12:00:00.000Z",
                                    "resolution": "minute"
                                },
                                "points": [
                                    {
                                        "offset": 37,
                                        "samples": 3,
                                        "sum": 1
                                    },
                                    {
                                        "offset": 38,
                                        "samples": 12,
                                        "sum": 6
                                    },
                                    {
                                        "offset": 39,
                                        "samples": 7,
                                        "sum": 4
                                    },
                                    ...etc
                                ]
                            }
                        ]
                    }
                ],
                "id": "Motion:001",
                "isPattern": false,
                "type": "Motion"
            },
            "statusCode": {
                "code": "200",
                "reasonPhrase": "OK"
            }
        }
    ]
}

Querying for the mean value within a time period is not directly supported.

This example shows sum of luminosity values from Lamp:001 over each minute. When combined with the number of samples the within the time period an average can be calculated from the data.

To obtain the short term history of a context entity attribute, send a GET request to ../STH/v1/contextEntities/type/<Entity>/id/<entity-id>/attributes/<attribute>

The aggrMethod parameter determines the type of aggregation to perform over the time series, the aggrPeriod is one of second, minute, hour or day.

9️⃣ Request:

curl -X GET \
  'http://localhost:8666/STH/v1/contextEntities/type/Lamp/id/Lamp:001/attributes/luminosity?aggrMethod=sum&aggrPeriod=minute' \
  -H 'fiware-service: openiot' \
  -H 'fiware-servicepath: /'

Response:

{
    "contextResponses": [
        {
            "contextElement": {
                "attributes": [
                    {
                        "name": "luminosity",
                        "values": [
                            {
                                "_id": {
                                    "attrName": "luminosity",
                                    "origin": "2018-06-21T12:00:00.000Z",
                                    "resolution": "minute"
                                },
                                "points": [
                                    {
                                        "offset": 20,
                                        "samples": 9,
                                        "sum": 17382
                                    },
                                    {
                                        "offset": 21,
                                        "samples": 8,
                                        "sum": 15655
                                    },
                                    {
                                        "offset": 22,
                                        "samples": 5,
                                        "sum": 9630
                                    },
                                    ...etc
                                ]
                            }
                        ]
                    }
                ],
                "id": "Lamp:001",
                "isPattern": false,
                "type": "Lamp"
            },
            "statusCode": {
                "code": "200",
                "reasonPhrase": "OK"
            }
        }
    ]
}

List the minimum of a value over a time period

This example shows minimum luminosity values from Lamp:001 over each minute

To obtain the short term history of a context entity attribute, send a GET request to ../STH/v1/contextEntities/type/<Entity>/id/<entity-id>/attributes/<attribute>

The aggrMethod parameter determines the type of aggregation to perform over the time series, the aggrPeriod is one of second, minute, hour or day.

The luminocity of the Smart Lamp is continually changing and therefore tracking the minimum value makes sense. The Motion Sensor is not suitable for this as it only offers binary values.

1️⃣0️⃣ Request:

curl -X GET \
  'http://localhost:8666/STH/v1/contextEntities/type/Lamp/id/Lamp:001/attributes/luminosity?aggrMethod=min&aggrPeriod=minute' \
  -H 'fiware-service: openiot' \
  -H 'fiware-servicepath: /'

Response:

{
    "contextResponses": [
        {
            "contextElement": {
                "attributes": [
                    {
                        "name": "luminosity",
                        "values": [
                            {
                                "_id": {
                                    "attrName": "luminosity",
                                    "origin": "2018-06-21T12:00:00.000Z",
                                    "resolution": "minute"
                                },
                                "points": [
                                    {
                                        "offset": 20,
                                        "samples": 9,
                                        "min": 1793
                                    },
                                    {
                                        "offset": 21,
                                        "samples": 8,
                                        "min": 1819
                                    },
                                    {
                                        "offset": 22,
                                        "samples": 5,
                                        "min": 1855
                                    }, ..etc
                                ]
                            }
                        ]
                    }
                ],
                "id": "Lamp:001",
                "isPattern": false,
                "type": "Lamp"
            },
            "statusCode": {
                "code": "200",
                "reasonPhrase": "OK"
            }
        }
    ]
}

List the maximum of a value over a time period

This example shows maximum luminosity values from Lamp:001 over each minute

To obtain the short term history of a context entity attribute, send a GET request to ../STH/v1/contextEntities/type/<Entity>/id/<entity-id>/attributes/<attribute>

The aggrMethod parameter determines the type of aggregation to perform over the time series, the aggrPeriod is one of second, minute, hour or day.

1️⃣1️⃣ Request:

curl -X GET \
  'http://localhost:8666/STH/v1/contextEntities/type/Lamp/id/Lamp:001/attributes/luminosity?aggrMethod=max&aggrPeriod=minute' \
  -H 'fiware-service: openiot' \
  -H 'fiware-servicepath: /'

Response:

{
    "contextResponses": [
        {
            "contextElement": {
                "attributes": [
                    {
                        "name": "luminosity",
                        "values": [
                            {
                                "_id": {
                                    "attrName": "luminosity",
                                    "origin": "2018-06-21T12:00:00.000Z",
                                    "resolution": "minute"
                                },
                                "points": [
                                    {
                                        "offset": 20,
                                        "samples": 9,
                                        "max": 2005
                                    },
                                    {
                                        "offset": 21,
                                        "samples": 8,
                                        "max": 2006
                                    },
                                    {
                                        "offset": 22,
                                        "samples": 5,
                                        "max": 1988
                                    },
                                    ...etc
                                ]
                            }
                        ]
                    }
                ],
                "id": "Lamp:001",
                "isPattern": false,
                "type": "Lamp"
            },
            "statusCode": {
                "code": "200",
                "reasonPhrase": "OK"
            }
        }
    ]
}

formal mode (Cygnus + STH-Comet)

The formal configuration is uses Cygnus to persist historic context data into a MongoDB database in the same manner as had been presented in the previous tutorial. The existing MongoDB instance (listening on the standard 27017 port) is used to hold data related to the Orion Context Broker, the IoT Agent and the historic context data persisted by Cygnus. STH-Comet is also attached to the same database to read data from it. The overall architecture can be seen below:

Database Server Configuration

mongo-db:
    image: mongo:3.6
    hostname: mongo-db
    container_name: db-mongo
    ports:
        - "27017:27017"
    networks:
        - default
    command: --bind_ip_all --smallfiles

STH-Comet Configuration

sth-comet:
    image: fiware/sth-comet
    hostname: sth-comet
    container_name: fiware-sth-comet
    depends_on:
        - mongo-db
    networks:
        - default
    ports:
        - "8666:8666"
    environment:
        - STH_HOST=0.0.0.0
        - STH_PORT=8666
        - DB_PREFIX=sth_
        - DB_URI=mongo-db:27017
        - LOGOPS_LEVEL=DEBUG

Cygnus Configuration

cygnus:
    image: fiware/cygnus-ngsi:latest
    hostname: cygnus
    container_name: fiware-cygnus
    depends_on:
        - mongo-db
    networks:
        - default
    expose:
        - "5080"
    ports:
        - "5050:5050"
        - "5080:5080"
    environment:
        - "CYGNUS_MONGO_HOSTS=mongo-db:27017"
        - "CYGNUS_LOG_LEVEL=DEBUG"
        - "CYGNUS_SERVICE_PORT=5050"
        - "CYGNUS_API_PORT=5080"

The sth-comet container is listening on one port:

  • The Operations for port for STH-Comet - 8666 is where the service will be listening for time based query requests from cUrl or Postman

The sth-comet container is driven by environment variables as shown:

Key Value Description
STH_HOST 0.0.0.0 The address where STH-Comet is hosted - within this container it means all IPv4 addresses on the local machine
STH_PORT 8666 Operations Port that STH-Comet listens on
DB_PREFIX sth_ The prefix added to each database entity if none is provided
DB_URI mongo-db:27017 The MongoDB server which STH-Comet will contact to persist historical context data
LOGOPS_LEVEL DEBUG The logging level for STH-Comet

The cygnus container is listening on two ports:

  • The Subscription Port for Cygnus - 5050 is where the service will be listening for notifications from the Orion context broker
  • The Management Port for Cygnus - 5080 is exposed purely for tutorial access - so that cUrl or Postman can make provisioning commands without being part of the same network.

The cygnus container is driven by environment variables as shown:

Key Value Description
CYGNUS_MONGO_HOSTS mongo-db:27017 Comma separated list of MongoDB servers which Cygnus will contact to persist historical context data
CYGNUS_LOG_LEVEL DEBUG The logging level for Cygnus
CYGNUS_SERVICE_PORT 5050 Notification Port that Cygnus listens when subscribing to context data changes
CYGNUS_API_PORT 5080 Port that Cygnus listens on for operational reasons

formal mode - Start up

To start the system using the formal configuration using Cygnus and STH-Comet, run the following command:

./services cygnus

STH-Comet - Checking Service Health

Once STH-Comet is running, you can check the status by making an HTTP request to the exposed STH_PORT port. If the response is blank, this is usually because STH-Comet is not running or is listening on another port.

1️⃣2️⃣ Request:

curl -X GET \
  'http://localhost:8666/version'

Response:

The response will look similar to the following:

{
    "version": "2.3.0-next"
}

Cygnus - Checking Service Health

Once Cygnus is running, you can check the status by making an HTTP request to the exposed CYGNUS_API_PORT port. If the response is blank, this is usually because Cygnus is not running or is listening on another port.

1️⃣3️⃣ Request:

curl -X GET \
  'http://localhost:5080/v1/version'

Response:

The response will look similar to the following:

{
    "success": "true",
    "version": "1.8.0_SNAPSHOT.ed50706880829e97fd4cf926df434f1ef4fac147"
}

Troubleshooting: What if either response is blank ?

  • To check that a docker container is running try
docker ps

You should see several containers running. If sth-comet or cygnus is not running, you can restart the containers as necessary.

Generating Context Data

For the purpose of this tutorial, we must be monitoring a system where the context is periodically being updated. The dummy IoT Sensors can be used to do this. Open the device monitor page at http://localhost:3000/device/monitor and unlock a Smart Door and switch on a Smart Lamp. This can be done by selecting an appropriate the command from the drop down list and pressing the send button. The stream of measurements coming from the devices can then be seen on the same page:

formal mode - Subscribing Cygnus to Context Changes

In formal mode, Cygnus is responsible for the persistence of historic context data. Once a dynamic context system is up and running, we need to set up a subscription in the Orion Context Broker to notify Cygnus of changes in context - STH-Comet will only be used to read the persisted data.

Cygnus - Aggregate Motion Sensor Count Events

The rate of change of the Motion Sensor is driven by events in the real-world. We need to receive every event to be able to aggregate the results.

This is done by making a POST request to the /v2/subscription endpoint of the Orion Context Broker.

  • The fiware-service and fiware-servicepath headers are used to filter the subscription to only listen to measurements from the attached IoT Sensors
  • The idPattern in the request body ensures that Cygnus will be informed of all Motion Sensor data changes.
  • The notification url must match the configured CYGNUS_API_PORT

1️⃣4️⃣ Request:

curl -iX POST \
  'http://localhost:1026/v2/subscriptions/' \
  -H 'Content-Type: application/json' \
  -H 'fiware-service: openiot' \
  -H 'fiware-servicepath: /' \
  -d '{
  "description": "Notify Cygnus of all Motion Sensor count changes",
  "subject": {
    "entities": [
      {
        "idPattern": "Motion.*"
      }
    ],
    "condition": {
      "attrs": [
        "count"
      ]
    }
  },
  "notification": {
    "http": {
      "url": "http://cygnus:5051/notify"
    },
    "attrs": [
      "count"
    ]
  }
}'

Cygnus - Sample Lamp Luminosity

The luminosity of the Smart Lamp is constantly changing, we only need to sample the values to be able to work out relevant statistics such as minimum and maximum values and rates of change.

This is done by making a POST request to the /v2/subscription endpoint of the Orion Context Broker and including the throttling attribute in the request body.

  • The fiware-service and fiware-servicepath headers are used to filter the subscription to only listen to measurements from the attached IoT Sensors
  • The idPattern in the request body ensures that Cygnus will be informed of all Smart Lamp data changes only
  • The notification url must match the configured CYGNUS_API_PORT
  • The throttling value defines the rate that changes are sampled.

1️⃣5️⃣ Request:

curl -iX POST \
  'http://localhost:1026/v2/subscriptions/' \
  -H 'Content-Type: application/json' \
  -H 'fiware-service: openiot' \
  -H 'fiware-servicepath: /' \
  -d '{
  "description": "Notify Cygnus to sample Lamp luminosity every five seconds",
  "subject": {
    "entities": [
      {
        "idPattern": "Lamp.*"
      }
    ],
    "condition": {
      "attrs": [
        "luminosity"
      ]
    }
  },
  "notification": {
    "http": {
      "url": "http://cygnus:5051/notify"
    },
    "attrs": [
      "luminosity"
    ]
  },
  "throttling": 5
}'

formal mode - Time Series Data Queries

When reading data from the database, there is no difference between minimal and formal mode, please refer to the previous section of this tutorial to request time-series data from STH-Comet

Accessing Time Series Data Programmatically

Once the JSON response for a specified time series has been retrieved, displaying the raw data is of little use to an end user. It must be manipulated to be displayed in a bar chart, line graph or table listing. This is not within the domain of STH-Comet as it not a graphical tool, but can be delegated to a mashup or dashboard component such as Wirecloud or Knowage

It can also be retrieved and displayed using a third-party graphing tool appropriate to your coding environment - for example chartjs. An example of this can be found within the history controller in the Git Repository

The basic processing consists of two-step - retrieval and attribute mapping, sample code can be seen below:

function readCometLampLuminosity(id, aggMethod) {
    return new Promise(function(resolve, reject) {
        const url = "http://sth-comet:8666/STH/v1/contextEntities/type/Lamp/id/Lamp:001/attributes/luminosity";
        const options = {
            method: "GET",
            url: url,
            qs: { aggrMethod: aggMethod, aggrPeriod: "minute" },
            headers: {
                "fiware-servicepath": "/",
                "fiware-service": "openiot"
            }
        };

        request(options, (error, response, body) => {
            return error ? reject(error) : resolve(JSON.parse(body));
        });
    });
}
function cometToTimeSeries(cometResponse, aggMethod) {
    const data = [];
    const labels = [];

    const values = cometResponse.contextResponses[0].contextElement.attributes[0].values[0];
    let date = moment(values._id.origin);

    _.forEach(values.points, element => {
        data.push({ t: date.valueOf(), y: element[aggMethod] });
        labels.push(date.format("HH:mm"));
        date = date.clone().add(1, "m");
    });

    return {
        labels,
        data
    };
}

The modified data is then passed to the frontend to be processed by the third-party graphing tool. The result is shown here: http://localhost:3000/device/history/urn:ngsi-ld:Store:001

Next Steps

Want to learn how to add more complexity to your application by adding advanced features? You can find out by reading the other tutorials in this series


License

MIT © 2018-2020 FIWARE Foundation e.V.