Notifications
You must be signed in to change notification settings - Fork 0
/
LUS_Setup_test.m
163 lines (143 loc) · 7.22 KB
/
LUS_Setup_test.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
%% test
nAvg = 1;% number of soft averages
hard_average = 1024; % number of hard averages; Changing hard avg requires freeGage
inputRange = 10000;% [mV] 10000, 4000, 2000, 1000, 400, 200, 100
segCount = nAvg;
Fs = 500e6;
dt = 1/Fs;
t_0 = 0e-6; t_end = 4e-6; % us HFM18=3.4us/1.7us [1.5 3.74]
trigDelay = t_0 * Fs;
endpoint = t_end * Fs; % FPGA average take 65 KSamples per channel / 2 channel
t = [t_0+dt:dt:t_end];
nSamples = (endpoint - trigDelay); %2048; % Number of samples
detType = 'TAM50';%TAM50: 500e6, TAM100: 1e9
acqRes = 32;
acqMode = 'Single'; % this is the single acquisition code
nSegments = ceil(nSamples/acqRes);
TriggerTimeout = -1; % % Wait until trigger arrives [us] (-1: inf)
handle = DAQ
%% --- Get System Info
[ret, sysinfo] = CsMl_GetSystemInfo(handle);
CsMl_ErrorHandler(ret, 1, handle);
%%
% We'll query the driver for the acquisition
% parameters so we know the mode before we change it to use
% the extended options.
[ret, acqInfo] = CsMl_QueryAcquisition(handle);
% If we change the mode, we'll keep a copy of the original capture mode in
% old_mode in case we need it later
% acqInfo.Mode = 2;
Old_Mode = acqInfo.Mode;
% --- Set Acquisition Parameters
if strcmp(detType, 'RSOM100')
acqInfo.SampleRate = 1e9; % Set sampling rate
elseif strcmp(detType, 'RSOM50')
acqInfo.SampleRate = 500e6;
elseif strcmp(detType, 'TAM100')
acqInfo.SampleRate = 1e9;
elseif strcmp(detType, 'TAM50')
acqInfo.SampleRate = 500e6;
elseif strcmp(detType, 'SOI')
acqInfo.SampleRate = 250e6;
elseif strcmp(detType, 'LUS100')
acqInfo.SampleRate = 500e6;
else
disp('Wrong setup file.');
return;
end
disp(sprintf('\nSetup file %s accessed\n', detType));
acqInfo.Mode = CsMl_Translate(acqMode, 'Mode');
% setup acqInfo.Mode using hardware averaging FPGA image
if (hard_average > 1)
% Check to see which optional fpga images are available
[ret, options] = CsMl_GetExtendedOptions(handle);
% Calculate the active channel count using the original
% mode, before we add the MulRec Averaging constant
ChannelCount = acqInfo.Mode * sysinfo.BoardCount;
% This next part determines if multiple record averaging is available
% and which fpga image (1 or 2) it is on. If you know that your CompuScope
% system has multiple record averaging and which image it is on you can
% skip this step and just "or" (or add) the appropriate constant to the
% acquisition mode. The constant for image 1 is 0x40000000 and for image 2
% is 0x80000000.
mulrecavg_option = CsMl_Translate('mulrec averaging', 'Options');
if options(1).OptionConstant == mulrecavg_option
mode = acqInfo.Mode + options(1).ModeConstant;
elseif options(2).OptionConstant == mulrecavg_option
mode = acqInfo.Mode + options(2).ModeConstant;
else
% system does not support mulrec averaging with TD, we'll try
% regular mulrec averaging which has a value of 16
disp('System does not support Multiple Record Averaging TD');
disp('Trying to load Multiple Record Averaging');
if options(1).OptionConstant == 16
mode = acqInfo.Mode + options(1).ModeConstant;
elseif options(2).OptionConstant == 16
mode = acqInfo.Mode + options(2).ModeConstant;
else
disp('System does not support Multiple Record Averaging');
CsMl_FreeSystem(handle);
return;
end;
end;
acqInfo.Mode = mode;
CsMl_SetMulrecAverageCount(handle, hard_average);
CsMl_ErrorHandler(ret, 1, handle);
% acqInfo.Mode = CsMl_Translate(acqMode, 'Mode');
% acqInfo.Mode = bitor(acqInfo.Mode,hex2dec(num2str(40000000))); % 0x40000000 is for FPGA image 1; 0x80000000 is for image 2
% CsMl_SetMulrecAverageCount(handle, hard_average);
% ret = CsMl_Commit(handle);
% CsMl_ErrorHandler(ret, 1, handle);
elseif (hard_average <= 1)
acqInfo.Mode = CsMl_Translate(acqMode, 'Mode');
end
% acqInfo.SegmentCount = 1;
% acqInfo.Depth = 130e3; % maximum hardware segment samples
% acqInfo.SegmentSize = 130e3;
% acqInfo.ExtClock = 0;
acqRes = 32; %!!! 32 is the minimum resolution of a cell
acqInfo.SegmentCount = segCount;
acqInfo.Depth = nSegments * acqRes;
acqInfo.SegmentSize = nSegments * acqRes; % Number of Samples
acqInfo.TriggerTimeout = TriggerTimeout; % Wait until trigger arrives [us] (-1: inf)
% acqInfo.TriggerHoldoff = 0; % Dead time before awaiting a trigger signal
acqInfo.TriggerDelay = trigDelay; % 1GS/s: focus @ 1740
% time_stamp_clock = CsMl_Translate('FixedClock', 'TimeStamp'); % Number of omitted samples at the beginning
% acqInfo.TimeStampConfig = time_stamp_clock;
% acqInfo.SampleResolution = -2097152; % by default resolution is -2097152, but not 2^32, because for 1024 12bit-sequence adding up it is enough.
% acqInfo.SampleSize = 4; % 4 for hardware average and 2 for none
ret = CsMl_ConfigureAcquisition(handle, acqInfo);
CsMl_ErrorHandler(ret, 1, handle);
% [ret, acqInfo] = CsMl_QueryAcquisition(handle);
%%
% Set up all the channels even though
% they might not all be used. For example
% in a 2 board master / slave system, in single channel
% mode only channels 1 and 3 are used.
for i = 1:sysinfo.ChannelCount
chan(i).Channel = i;
chan(i).Coupling = CsMl_Translate('AC', 'Coupling'); % Set the coupling to input TD channel to DC
% chan(i).DiffInput = 0;
chan(i).InputRange = inputRange; % 10000, 4000, 2000, 1000, 400, 200 % Set total input voltage range
chan(i).Impedance = 50; % Input impedance (according to cable)
% chan(i).DcOffset = 0; % Baseline offset
% chan(i).DirectAdc = 0;
% chan(i).Filter = 0;
end
% chan(1).InputRange = 2000;
% chan(2).InputRange = 4000;
ret = CsMl_ConfigureChannel(handle, chan);
CsMl_ErrorHandler(ret, 1, handle);
% --- Set Trigger Parameters
trig.Trigger = 1;
trig.Slope = CsMl_Translate('Positive', 'Slope');
trig.Level = 20; % Trigger threshold
trig.Source = 1; % Trigger signal on channel -1
% trig.ExtCoupling = CsMl_Translate('DC', 'ExtCoupling'); % ExtCoupling % Set the coupling to trigger channel to DC
% trig.ExtRange = 10000; % Set total trigger signal voltage range
% trig.ExtImpedance= 50;
ret = CsMl_ConfigureTrigger(handle, trig);
CsMl_ErrorHandler(ret, 1, handle);
ret = 1;
% Setup(DAQ, segCount, trigDelay, inputRange, nSegments, acqMode, detType, TriggerTimeout, hard_average); % Set acquisition, channel and trigger parameters
pause(1);ret = CsMl_Commit(DAQ)