You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Describe the bug
A clear and concise description of what the bug is.
To Reproduce
Steps to reproduce the behavior:
DataFusion CLI v10.0.0
❯ selectcast('1969-01-01T00:00:00.1' as timestamp);
thread 'main' panicked at 'invalid or out-of-range datetime', /Users/willy/.cargo/registry/src/github.com-1ecc6299db9ec823/chrono-0.4.19/src/naive/datetime.rs:117:18
note: run with `RUST_BACKTRACE=1` environment variable to display a backtrace
while this works
DataFusion CLI v10.0.0
❯ selectcast('1969-01-01T00:00:00' as timestamp);
+------------------------------------------------------------------+
| CAST(Utf8("1969-01-01T00:00:00") AS Timestamp(Nanosecond, None)) |
+------------------------------------------------------------------+
| 1968-12-31 16:00:00 |
+------------------------------------------------------------------+
Expected behavior
A clear and concise description of what you expected to happen.
Additional context
Add any other context about the problem here.
The text was updated successfully, but these errors were encountered:
Spent some time tracking this down, root of the problem was on the arrow side doing the conversions. This was not working properly for negative values.
Luckly it looks like it was fixed 4 days ago and in the 20.0.0 release;
Describe the bug
A clear and concise description of what the bug is.
To Reproduce
Steps to reproduce the behavior:
while this works
Expected behavior
A clear and concise description of what you expected to happen.
Additional context
Add any other context about the problem here.
The text was updated successfully, but these errors were encountered: