Sonoff POW R2 duplicate mqtt message #2891
Comments
For help please post status 0 |
Hi Jason, can you explain me what is "Status 0" ? |
In web front end hit button "Console" |
|
From status 0 I suggest to disable serial logging as the interface is used by the POW energy monitoring hardware: With low loads any powerdelta might report a message so I would disable powerdelta for now and see what happens: As teleperiod is set too 300 (seconds) I cannot explain why you receive messages every 20 seconds... |
With |
Enable
|
Here it is:
|
Looking at the CF count (byte 21and 22 being E2, E3, E4) there seems to be a very low power load connected. This is also represented in many unmeasurable power loads indicated by byte 20 which should say 71 when power, voltage and current could be measured. I see many 61 = invalid power meaning to power load is too low to measure. Suggestions:
|
Ok you're right... the load was minimal (5w)... I've attached a 60w light bulb and now it work! |
Hi all,
I've flashed the Sonoff POW R2 with Tasmota (self compiled with platformio).
In the main page I see no power value
In the console I've found that there's always a duplicate MQTT message for the current/power value:
Anoyone else having the same problem? solution?
Thanks
Andrea