-
Notifications
You must be signed in to change notification settings - Fork 20
/
LogViewer.Receivers.Winipc.Settings.pas
141 lines (113 loc) · 3.07 KB
/
LogViewer.Receivers.Winipc.Settings.pas
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
{
Copyright (C) 2013-2022 Tim Sinaeve tim.sinaeve@gmail.com
Licensed under the Apache License, Version 2.0 (the "License");
you may not use this file except in compliance with the License.
You may obtain a copy of the License at
http://www.apache.org/licenses/LICENSE-2.0
Unless required by applicable law or agreed to in writing, software
distributed under the License is distributed on an "AS IS" BASIS,
WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
See the License for the specific language governing permissions and
limitations under the License.
}
unit LogViewer.Receivers.Winipc.Settings;
{ Persistable settings for WinIPC receivers. }
interface
uses
System.Classes,
Spring;
type
TWinipcSettings = class(TPersistent)
const
DEFAULT_POLLING_INTERVAL = 10;
private
FOnChanged : Event<TNotifyEvent>;
FEnabled : Boolean;
FPollingInterval : Integer;
protected
{$REGION 'property access methods'}
function GetOnChanged: IEvent<TNotifyEvent>;
function GetEnabled: Boolean;
procedure SetEnabled(const Value: Boolean);
function GetPollingInterval: Integer;
procedure SetPollingInterval(const Value: Integer);
{$ENDREGION}
procedure Changed;
public
procedure AfterConstruction; override;
destructor Destroy; override;
procedure Assign(Source: TPersistent); override;
property OnChanged: IEvent<TNotifyEvent>
read GetOnChanged;
published
property Enabled: Boolean
read GetEnabled write SetEnabled;
property PollingInterval: Integer // in ms
read GetPollingInterval write SetPollingInterval
default DEFAULT_POLLING_INTERVAL;
end;
implementation
{$REGION 'construction and destruction'}
procedure TWinipcSettings.AfterConstruction;
begin
inherited AfterConstruction;
FPollingInterval := DEFAULT_POLLING_INTERVAL;
FOnChanged.UseFreeNotification := False;
end;
destructor TWinipcSettings.Destroy;
begin
FOnChanged.RemoveAll(Self);
inherited Destroy;
end;
{$ENDREGION}
{$REGION 'property access methods'}
function TWinipcSettings.GetEnabled: Boolean;
begin
Result := FEnabled;
end;
procedure TWinipcSettings.SetEnabled(const Value: Boolean);
begin
if Value <> Enabled then
begin
FEnabled := Value;
Changed;
end;
end;
function TWinipcSettings.GetOnChanged: IEvent<TNotifyEvent>;
begin
Result := FOnChanged;
end;
function TWinipcSettings.GetPollingInterval: Integer;
begin
Result := FPollingInterval;
end;
procedure TWinipcSettings.SetPollingInterval(const Value: Integer);
begin
if Value <> PollingInterval then
begin
FPollingInterval := Value;
Changed;
end;
end;
{$ENDREGION}
{$REGION 'protected methods'}
procedure TWinipcSettings.Changed;
begin
FOnChanged.Invoke(Self);
end;
{$ENDREGION}
{$REGION 'public methods'}
procedure TWinipcSettings.Assign(Source: TPersistent);
var
LSettings: TWinipcSettings;
begin
if Source is TWinipcSettings then
begin
LSettings := TWinipcSettings(Source);
Enabled := LSettings.Enabled;
end
else
inherited Assign(Source);
end;
{$ENDREGION}
end.