Description of the bug

The current DIA-NN used by the pipeline is v1.8.1, DIA output lacks experimental mass to charge, and the corresponding column in DIA-NN v1.8 is "precursor.mz". This deficiency will affect the generation of QC reports.

Command used and terminal output

No response

Relevant files

No response

System information

No response

@WangHong007 WangHong007 added the bug Something isn't working label Jun 24, 2022
@vdemichev
Copy link

A comment: experimental mass to charge might be missing in DIA data (no MS1 signal detected). In fact, DIA data sometimes does not have MS1 at all.