  • SetFixedVoltage immediately changes the current voltage but does not interrupt ongoing pulse trains
  • ContinuousLoopConfiguration differs between V1 and V2:
    • In v2 it is triggered immediately on setting the parameter (this means that you can start a loop on configuration)
    • In v1 it starts on trigger, but after the first train it does not make bursts (after the first full burst pulse train, it repeats a train of pulses instead of a train of bursts)