# Set the general options of our simulation
options:
minimize: yes
verbose: yes
default_number_of_iterations: 500
temperature: 300*kelvin
pressure: 1*atmosphere
output_dir: all-ligands-explicit-output
# Configure the specific molecules we will use for our systems
molecules:
# Define our receptor, T4-Lysozyme, we can call it whatever we want so we just use its name here as the directive
t4-lysozyme:
filepath: input/receptor.pdbfixer.pdb
# Define our ligands
binders:
# This is actually a "CSV" file where the delimiter is a comma or a
# semicolon, and each row contains the SMILES representation of a molecule.
filepath: input/L99A-binders.csv
antechamber:
charge_method: bcc
# Choose to simulate all molecules (1 at a time).
# This is the default behavior but we specify it for this example
select: all
# Define the solvent for our system
solvents:
pme:
nonbonded_method: PME
nonbonded_cutoff: 9*angstroms
clearance: 16*angstroms
positive_ion: Na+
negative_ion: Cl-
systems:
t4-ligand:
receptor: t4-lysozyme
ligand: binders
solvent: pme
leap:
parameters: [leaprc.protein.ff14SB, leaprc.gaff2, leaprc.water.tip4pew]
# When ligands are generated from SMILES they have a random position.
# Setting "pack: yes" pulls the ligand close to the receptor ensuring
# that your solvation box won't be too big.
pack: yes
protocols:
absolute-binding:
complex:
alchemical_path:
lambda_electrostatics: [1.00, 1.00, 1.00, 1.00, 1.00, 0.90, 0.80, 0.70, 0.60, 0.50, 0.40, 0.30, 0.20, 0.10, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00]
lambda_sterics: [1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 0.90, 0.80, 0.70, 0.60, 0.50, 0.40, 0.30, 0.20, 0.10, 0.00]
# Set lambda restraints reverse of coupling parameter.
lambda_restraints: [0.00, 0.25, 0.50, 0.75, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00]
solvent:
alchemical_path:
lambda_electrostatics: [1.00, 0.90, 0.80, 0.70, 0.60, 0.50, 0.40, 0.30, 0.20, 0.10, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00]
lambda_sterics: [1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 1.00, 0.90, 0.80, 0.70, 0.60, 0.50, 0.40, 0.30, 0.20, 0.10, 0.00]
# Here we combine the system and the protocol to make an experiment
experiments:
system: t4-ligand
protocol: absolute-binding
restraint:
type: Harmonic # Keep the ligand near the protein