Comments
Hi, it is pretty easy with the service climate.set_temperature. Here is an exemple:
I don't use neviweb automation as HA is a lot more powerfull. |
By the way it is not a neviweb service but a native HA service, climate.set_temperature |
You're right, I see that I can pick the HA climate.set_temperature service in conjonction with the climate.neviweb130.* entities. Amazing. Used it already to control a non-smart Fujitsu heatpump using a Wi-Fi to IR/RF bridge with the SmartIR integration. My goal is also to use the hydroqc.ca HA addon and use the various winter credit sensors to trigger various automatisations based on timestamps. Didn't find yet how to use the timestamp (yyyy-mm-dd hh:mm:ss.) format to trigger automatisations. |
For the winter credit I catch directly the email that Hydro is sendingthe day before and HA is able to extract the peak period. I've posted all the informations in this blog: |
Take a look at it here https://hydroqc.ca/docs/reference/sensors/ You can use a bunch of sensors: https://hydroqc.ca/docs/reference/wc-sensors/ And do advanced routines that do not only take into consideration ''peak'' periods but also ''anchor'' periods to maximize your winter credit return: https://hydroqc.ca/docs/winter-credits/optimization-logics/ For exemple, their ''sensor.hydroqc_maison_next_critical_peak_start'' entity return a timestamp. Not sure yet how to start an automatisation from a timestamp, just started in HA 2 weeks ago. |
OK let me check this. Look very interesting. I'll tell you how to decode the timestamp to set your automation at the wright time |
In fact I had this installed long time ago at the beginning but there was nothing about peak period. |
There should be something wrong I get this error |
pyhydroquebec and hydroqc are two different projects; you should remove pyhydroquebec since hydroqc is way more complete. I installed hydroqc by the HA Addons menu; added their custom repository (https://gitlab.com/hydroqc/hydroqc-hass-addons) and configured it directly by the Hydroqc Add-on configuration tab. A lot of account parameters need to be entered, you must have one of your online bill opened to gather all the information needed such as the client number, account number and contract number. |
OK I've lots of sensors: but sensor.hydroqc_maison_next_critical_peak_start is unavailable |
According to their doc: ''wc next critical peak start / end: The timestamp for the next critical peak period start and end. Can be used as triggers in home-assistant automations. Will be “Unavailable” when the next peak event is not critical'' However, still in their doc: ''wc next anchor start / end: The timestamp for the next anchor period start and end. Can be used as triggers in home-assistant automations. Will always have a value But still unavailable; my guess is that it shows ''unavailable'' because the winter credit starts december 1st. |
Sound good. Do you have a timestamp value somewhere? I can start to work on extracting date and time from it to find the exact peak period start. |
Lot of answers in their Discord channel (browser compatible, no need to register for read-only): https://discord.com/invite/BTPDntfaXH Just found out a post that confirms ''unavailable'' timestamp entities will work december 1st I asked about the timestamp format and it's an Home Assistant standard: https://developers.home-assistant.io/docs/core/entity/sensor/#available-device-classes They have a demo blueprint here: https://gitlab.com/hydroqc/hass-blueprint-hydroqc/-/blob/main/hydroqc-winter-credits.yaml And it seems that we can simply use Trigger IDs from that blueprint to trigger automatisations. Making more sense. Edit 2022-11-04 11:20: You can add their blueprint to your HA with this link: https://my.home-assistant.io/redirect/blueprint_import/?blueprint_url=https%3A%2F%2Fraw.githubusercontent.com%2Fhydroqc%2Fhass-blueprint-hydroqc%2Fmain%2Fhydroqc-winter-credits.yaml |
Thank's lot of reading this weekend |
Everything is set on my end, ready for winter 22-23 :) Nice hydroqc, sinope-130 and SmartIR mix. |
Everything went fine here! :) How it went for you? (33.53kWh/35.07kWh) = 95.6% energy reduction during the afternoon peak :) By the way, do you know if we can live monitor the FS4220 Flow sensor (plugged into a ZigBee Sedna)? I would like to program an ''away from home'' mode: if activated and if the flow goes higher than 2L/min, shutoff the valve automatically. |
Very good score. better then me. I only got 16.78$ because my reference energy is too low, 10.7 kw in the morning and 30 for the evening. I can push to save 2 more kw for each peak but it will give me only 2$ more. I need to increase my reference by switching everything during the reference period. For you valve. you have the Water_leak_status attribute that turn on if the meeter detect a leak. to find out how much water is measured it is via the attributes: |
But if I do not use the GT130 gateway/Neviweb and I add the Zigbee valve directly with ZHA, there should be a way to extract the live sensor data? What I do to increase my energy consomption is that I preheat the house only during critical anchor periods and only by using baseboard heating. All winter I heat using heatpumps so my energy usage is very low but then during critical anchor periods I switch to basebord only and push to temp up to 23degC. I follow this logic: |
Data for water metering is passed by the same cluster as for the energy usage for the other devices. |
The big question is if the data is pushed out faster from the valve than once per hour, or it logs for an hour then push out. If it pushes like once per minute or per second I could just divide that L/hr value by 60 to get L/min or by 3600 to get L/sec. It should be able to detect a flow as low as 2L/min, which is 33mL/sec. |
The valve will automatically shut down if there is a small leak and switch the Water_leak_status attribute to «water» |
As the zigbee device are design for low energy concumption then I suspect that it will send only once per hour. But you can monitor that output to find out if it change avery minutes or every hour. |
Is Water_leak_status a neviweb130 entity? Does it trigger from leak detectors or from the flow? If it's from the flow, do you know its trigger value? (L/min?) |
Water_leak_status is triggered by the valve equipped with a flow meter. It is an attribute for your valve. It is possible that you have to activate it in Neviweb under your valve configuration. |
The trigger value is 2L/min for the 3/4 in and 4 L/min for the 1 in flow meter as I can see form Sinopé |
Look like there are many parameters adjustable for the flow meter in neviweb. If you have one with a sedna second gen then we can chack and add thoses parameters in HA with a service to be able to change them. If you have time |
https://support.sinopetech.com/en/neviweb/2.1.5.4.1/ Duration of abnormal flow before alert The minimum is 15 minutes. That's way too high. That means that if no leak detectors capture water, the house will be flooded for 15 minutes before ''Water_leak_status'' turns to ''water''. The idea is to set an ''away mode'' where the flow meter can capture the smallest flow possible which automatically means a leak since there's nobody home. |
can you pull the parameter available with the time values so I can add them in neviweb130. Open a debug console with F12 when your in the valve config to get all parameters and if there are a drop down menu for thos parameters give me the value availables. |
I'm testing my stat_interval parameter now and will create a branch for testing |
I do not have the valve yet; I ordered everything (valve 3/4 zigbee, flow meter 3/4 and a dozen detectors) at the boxing day sale; should receive everything in the 1st week of january. Just trying to understand how I'll setup this in HA prior to installation. That 15 minutes trigger setting is way too high; this is why I opted for the zigbee version in case I can retrieve the data faster than from Neviweb. |
A major leak should be catch by your leak sensor so the meter is there to detect small leak which won't do much dammage in 15 minutes |
Once you have them we will see if the values are updated more frequently. To find out you can check any hourly_kwh status of thermostat or switch you have already connected. When heating the hourly_kwh will increase during the hour. But for that we will need my stat_interval param which is almost ready |
Ok. It happened to me once. Water goes where gravity direct it to go and if a detector isn't exactly in the way, they are simply useless. A 2L/min leak can easily ruin that dining room hard floor. Over 30,000$ in insurance claim. |
OK my stat_interval config work so I'll make a new branch stat-intervall. I'll let you know when it is ready to test |
See https://github.com/claudegel/sinope-130/blob/stat-intervall branch if you want to test stat_interval |
Look like those parameter will be availables from neviweb |
Interessing. It'll tell you once my Sedna kit is installed. Should be around mid-january at last but hopefully sooner. |
Hello @claudegel, We had a critical peak yesterday, went all fine: Concerning the Sedna, I finally received my kit yesterday. It took Sinopé a long time to ship all the boxing day orders they had. I saw that you pushed an update to improve the Sedna valve; I'll tell you once the kit is installed so we could test a few thing to trigger an event based on the minimal flow rate (2L/min). |
Good I only got 5$ because my reference value is half of yours. |
Hello @claudegel,
Is there a way to increase or decrease thermostats setpoints by using sinope-130? I can see the setpoint as a state attribute (''temperature:'') field but I don't see any Neviweb service that could change a setpoint.
My goal would be to bypass the Sinopé Neviweb app for all automatisations, such as decreasing thermostats temperature during the night and increasing them next morning by using Home Assistant only.
Thank you very much for all your work.