We observed that a Dell 15G server held network packets for about 1 second when its iDRAC had been reset.
This delay of network packets caused the server's network links to get down for about 50 seconds.
This was because the BIRD Internet Routing Daemon for the network links was configured with 500 milliseconds BFD timeout as follows.
What
We observed that a Dell 15G server held network packets for about 1 second when its iDRAC had been reset.
This delay of network packets caused the server's network links to get down for about 50 seconds.
This was because the BIRD Internet Routing Daemon for the network links was configured with 500 milliseconds BFD timeout as follows.
min rx interval 100 ms
min tx interval 100 ms
multiplier
of 5cf. https://github.com/cybozu-go/neco/blob/release-2022.08.16-19406/installer/setup/templates.go#L15
cf. https://github.com/cybozu-go/neco/blob/release-2022.08.16-19406/ignitions/common/files/etc/bird/bird.conf#L9
Note that the settings of the network switches would also relate.
We should:
How
Describe how to address the issue.
Checklist
The text was updated successfully, but these errors were encountered: