(use upvote 👍 for attentions) Describe the bug
leaf_to_spine_redundancy_check is generating false positive message even if leaf is connected to multiple spines. This is seen for all the leafs in the fabric Script output
[Check 15/69] Leaf to Spine Redundancy check... FAIL - OUTAGE WARNING!!
Leaf Switch Name Spine Adjacencies Message
---------------- ----------------- -------
POD6-BL-801 The Leaf Switch has one or less spine adjacencies
POD6-APIC1# fabric 801 show lldp neighbors
----------------------------------------------------------------
Node 801 (POD6-BL-801)
----------------------------------------------------------------
Capability codes:
(R) Router, (B) Bridge, (T) Telephone, (C) DOCSIS Cable Device
(W) WLAN Access Point, (P) Repeater, (S) Station, (O) Other
Device ID Local Intf Hold-time Capability Port ID
POD6-SPN-901 Eth1/49 120 BR Eth1/1
POD6-SPN-902 Eth1/50 120 BR Eth1/1
POD6-SPN-903 Eth1/51 120 BR Eth1/1
Expected behavior
We should seen this failing only if leaf is single connected