media: rc: ir-rc6-decoder: enable toggle bit for Zotac remotes
The Zotac RC2604323/01G and RC2604329/02BG remotes use the 32-bit rc6 protocol and toggle bit 15 (0x8000) on repeated button presses, like MCE remotes. Add the customer code 0x80340000 to the 32-bit rc6 toggle handling code to get proper scancodes and toggle reports. Signed-off-by: Matthias Reichl <hias@horus.com> Signed-off-by: Sean Young <sean@mess.org> Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org>
1 parent 721074b commit b1f3775

File tree

1 file changed

+2
-0
lines changed

1 file changed

+2
-0
lines changed

drivers/media/rc/ir-rc6-decoder.c

Lines changed: 2 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -40,6 +40,7 @@
4040
#define RC6_6A_MCE_TOGGLE_MASK 0x8000 /* for the body bits */
4141
#define RC6_6A_LCC_MASK 0xffff0000 /* RC6-6A-32 long customer code mask */
4242
#define RC6_6A_MCE_CC 0x800f0000 /* MCE customer code */
43+
#define RC6_6A_ZOTAC_CC 0x80340000 /* Zotac customer code */
4344
#define RC6_6A_KATHREIN_CC 0x80460000 /* Kathrein RCU-676 customer code */
4445
#ifndef CHAR_BIT
4546
#define CHAR_BIT 8 /* Normally in <limits.h> */
@@ -246,6 +247,7 @@ static int ir_rc6_decode(struct rc_dev *dev, struct ir_raw_event ev)
246247
switch (scancode & RC6_6A_LCC_MASK) {
247248
case RC6_6A_MCE_CC:
248249
case RC6_6A_KATHREIN_CC:
250+
case RC6_6A_ZOTAC_CC:
249251
protocol = RC_PROTO_RC6_MCE;
250252
toggle = !!(scancode & RC6_6A_MCE_TOGGLE_MASK);
251253
scancode &= ~RC6_6A_MCE_TOGGLE_MASK;