Climax EMD-1ZBS power meter #3020
Comments
You forgot the screenshot for the simple metering cluster. |
Thanks @SwoopX: I've added the screenshots of all cluster info sub-sections (didn't know you could select them :D ) |
Thanks, but it looks like you haven't read the attributes via the button... |
This is after pressing "read": will retry though 👍 |
The device was probably not awake. |
Hmm, I've forced it to try "pairing" (not sure if that's what it's called in the ZigBee world). How would that be forced on other appliances, such as other meters? Trying to query through |
Now it looks ok-ish. But the values are all 0, probably due to a reset? Got no clue what the measurement units are. For now, I'd assume it's all in W. |
Hard to say: this thing came with zero manual, besides "press and hold for 10 seconds to start looking for a gateway".
Very likely |
Closing this as device is now supported with .79 beta. |
Amazing, will try reading through the diffs and give it a spin soon 👍 |
its frustrating to get or just find a shop for some zigbee devices :( thank you |
@00lex here you go: https://www.lupus-electronics.de/shop/Alarm-Smarthome/Smarthome-Hausautomation/LUPUSEC-Hauptstromz%E4hler-p.html Indeed, I had to contact Climax too in order to find a local reseller 🤷 |
Any solution for this? |
And would be nice if it could report watt and not kWh :( |
@spripe I suggest opening a new issue: my device now connects and shows up (as a siren) within Phoscon, but I didn't have time to debug further into metrics: doesn't seem to pick up anything meaningful, for now. |
Not gonna happen. Firstly, what you get is dependent on the device (99% report any values smaller than kWh) and secondly, the values exposed by the REST API are integers, no doubles. If you guys don't get any values in the simple metering cluster via deconz GUI, then there's not much we can do. In that case I'd suspect it to not collect any usable data. |
I'm very interested in this meter. Found some docs |
Attaching it here, since I don't trust the external URI to stay stable :D |
@Ocramius, so can you confirm that this meter works? Can you set attribute to enable the readings? |
@luka6000 I haven't really been able to get back to it - will certainly try it though, as I'm setting up my small solar farm, so it should come back to my priorities soon-ish :) |
Hey there! First of all, thanks for all the hard work around deconz: looks awesome so far!
I'm here to ask for device support as per https://github.com/dresden-elektronik/deconz-rest-plugin/wiki/Request-Device-Support
Device
This is a Climax EMD-1ZBS (https://zigbeealliance.org/zigbee_products/energy-meter-emd-1zbs/ & https://www.climax.com.tw/new/downloads/EMD-1ZBS%20Energy%20Meter_Product%20News_11.11.2016.pdf):
Not much available online about how it operates. Retailer is Lupus - they sell it re-branded as "Electric Meter Smart Home Module". It uses a diode to detect the blinking light on a power meter, and infers KWh metrics from that.
Screenshots
Cluster screenshot:
Lemme know if I can help in any way to get this one detected: couldn't find much about it in other gateways.
EDIT: further cluster info
0000 Basic:
0001 Power Configuration
0003 Identify
0702 Simple Metering