Controlling a shutters height on the Jalousie actuator (HmIP-BBL) is not working if the resp. channel (4:LEVEL) is added as Rollershutter typed item.
Expected Behaviour
Clicking up/down/stop buttons on any of OpenHUB interfaces should move the shutters
Observed Behaviour
Clicking up/down/stop does not move the shutters. The command is recognized within the logs:
19:07:40.969 [INFO ] [smarthome.event.ItemCommandEvent ] - Item 'BBL_TYPE' received command DOWN
19:07:40.971 [INFO ] [arthome.event.ItemStatePredictedEvent] - BBL_TYPE predicted to become DOWN
19:07:40.973 [INFO ] [smarthome.event.ItemStateChangedEvent] - BBL_TYPE changed from 0 to 100
However, it is possible to control the shutters if the channel is configured as Dimmer typed item (using the slider). The Rollershutter item is also working on the Blind actuator (HmIP-BROLL).
// homematic.items (Snip)
// Working
Rollershutter BROLL_TYPE "Level" (gRollershutter) {channel="homematic:HmIP-BROLL:deadbeef:001117deadbeef:4#LEVEL"}
// Not Working
Rollershutter BBL_TYPE "Level" (gRollershutter) {channel="homematic:HmIP-BBL:deadbeef:001118deadbeef:4#LEVEL"}
// Workaround (Working)
Dimmer BBL_TYPE "Level" (gRollershutter) {channel="homematic:HmIP-BBL:deadbeef:001118deadbeef:4#LEVEL"}
Your Environment
Tested on OH 2.4M6 and OH2.5M1 (Docker)
Ubuntu Linux 18.04.02 LTS Server
The text was updated successfully, but these errors were encountered:
Context
Controlling a shutters height on the Jalousie actuator (HmIP-BBL) is not working if the resp. channel (4:LEVEL) is added as Rollershutter typed item.
Expected Behaviour
Clicking up/down/stop buttons on any of OpenHUB interfaces should move the shutters
Observed Behaviour
Clicking up/down/stop does not move the shutters. The command is recognized within the logs:
However, it is possible to control the shutters if the channel is configured as Dimmer typed item (using the slider). The Rollershutter item is also working on the Blind actuator (HmIP-BROLL).
Your Environment
Tested on OH 2.4M6 and OH2.5M1 (Docker)
Ubuntu Linux 18.04.02 LTS Server