You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
The current for tracking the status of running components is (and will be when complete):
a AppData/Local/ElectrumSV-SDK/component_state.json file (with a file lock) is updated -> ComponentState.Running
on successful launch (determined by polling / health check)
then the status monitor will continue polling the running components to ensure that ComponentState.Running is still true...
if not then it would update component_state.json -> ComponentState.Failed for as long as the health check is failing. If the component comes online again then updates -> ComponentState.Running.
However, if the component is explicitly stopped then component_state.json -> ComponentState.Stopped.
Therefore the true status should be never any more than 1-2 seconds out of date at any given moment.
If the status_monitor is offline (it is optional). Then the ComponentState (Running / Failed / Stopped) are unreliable datapoints.
But the other contents of the component_state.json are always valid (such as the pid, component id, etc. etc.) and can be used to reliably stop / start / reset the components (the status monitor does not need to be online for this core functionality)
Alternative model as discussed with rt (Unsure if it is possible though).
To have the status_monitor promoted to take on more responsibility. Namely, the launching of applications such that they can block in a thread (using subprocess.Popen() calls)...
To make this workable we would need a way to pass environment variables to the subprocess.Popen() and a way to capture the return_code and stdout if the underlying server crashes or exits.
Would also need a way to run in background OR spawn a new console window with the above still holding true
Would also need a way to redirect the logs if running in the background.
The advantage of this is that it allows immediate and robust feedback when a spawned application crashes and returns the traceback + update -> ComponentState.Failed immediately, rather than relying on (a potentially tenuous) polling / health check system over the network.
As discussed:
We will stick with the current model for now but perhaps revisit this as at a later date.
The text was updated successfully, but these errors were encountered:
The current for tracking the status of running components is (and will be when complete):
AppData/Local/ElectrumSV-SDK/component_state.json
file (with a file lock) is updated -> ComponentState.Runningon successful launch (determined by polling / health check)
if not then it would update component_state.json -> ComponentState.Failed for as long as the health check is failing. If the component comes online again then updates -> ComponentState.Running.
If the status_monitor is offline (it is optional). Then the ComponentState (Running / Failed / Stopped) are unreliable datapoints.
But the other contents of the
component_state.json
are always valid (such as thepid
, componentid
, etc. etc.) and can be used to reliably stop / start / reset the components (the status monitor does not need to be online for this core functionality)Alternative model as discussed with rt (Unsure if it is possible though).
subprocess.Popen()
calls)...As discussed: