This is a short note on the discontinued Shrack Genio USDD-R 400 UPS (EAN code 9004840378757). This is a tower or rackmount UPS with 4000VA of power that is currently used as backup in my house. It operates with a DC voltage of nominal 108 V_dc which is significantly higher than 12V or 24V in consumer grade UPSes but 10 AGM lead-cell in batteries in series does the trick here. Another nice thing that I found about this UPS (which was missing its internal batteries when I purchased it) was the BATTERY EXTENSION connector on the back.
The BATTERY EXTENSION connector was not easy to recognize on first glance. After a while I stumbled by accident on a matching connector from WIELAND - the GST18I5 Pole Flat Male Connector available from multiple distributors and with the datasheet mirrored.
Datasheet for the GENIO Online UPS series
Manual for the GENIO Dual Maxi - USDDxxx which covers the USDD400 model
An application note on “REPLACEMENT OF THE BATTERY INSERTION BOX”