[BUG] Display Zero Tolerance works for value but still shows animated line #393

Open
Kartax opened this issue Sep 29, 2023 · 1 comment · Fixed by #547
Open

[BUG] Display Zero Tolerance works for value but still shows animated line #393

Kartax opened this issue Sep 29, 2023 · 1 comment · Fixed by #547
Labels
bug Something isn't working

Comments

@Kartax
Copy link

Kartax commented Sep 29, 2023

I configured my heatpump power consumption as "individual 2" and set a "zero tolerance" of 10 to not show standby power.
image

While that seems to work for the value itself (it is not shown anymore), i still see the powerline including the animated dot.
image

I expected the line and dot to not show up if value is zero or below zero tolerance.

@Kartax Kartax added the bug Something isn't working label Sep 29, 2023
@Kartax Kartax changed the title [BUG] Display Zero Tolerance works work value but still shows animated line [BUG] Display Zero Tolerance works for value but still shows animated line Oct 13, 2023
@flixlix flixlix linked a pull request Apr 14, 2024 that will close this issue
@flixlix
Copy link
Owner

flixlix commented Apr 14, 2024

fixed in #547
will be available in v0.2.1