\mainpage Main Page
DC Motor 8 click is a DC motor driver. It can drive simple DC motors with brushes, providing them with a significant amount of current and voltage up to 40V. The click has one control input, that uses the PWM signal from the host MCU. It uses the half-bridge topology to regulate the speed of the motor rotation, employs advanced dead-time circuitry that monitors the output stage, providing maximum switching efficiency and features an advanced technique to avoid shoot-through currents.
- Author : MikroE Team
- Date : sep 2020.
- Type : PWM type
We provide a library for the DcMotor8 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.
Package can be downloaded/installed directly form compilers IDE(recommended way), or downloaded from our LibStock, or found on mikroE github account.
This library contains API for DcMotor8 Click driver.
- Config Object Initialization function.
void dcmotor8_cfg_setup ( dcmotor8_cfg_t *cfg );
- Initialization function.
DCMOTOR8_RETVAL dcmotor8_init ( dcmotor8_t *ctx, dcmotor8_cfg_t *cfg );
- This function sets the PWM duty cycle.
void dcmotor8_set_duty_cycle ( dcmotor8_t *ctx, float duty_cycle );
- This function starts PWM module.
void dcmotor8_pwm_start ( dcmotor8_t *ctx );
- This function stops PWM module.
void dcmotor8_pwm_stop ( dcmotor8_t *ctx );
This click can drive simple DC motors with brushes, providing them with a significant amount of current and voltage up to 40V. The click has one control input, that uses the PWM signal from the host MCU. It uses the half-bridge topology to regulate the speed of the motor rotation, employs advanced dead-time circuitry that monitors the output stage, providing maximum switching efficiency and features an advanced technique to avoid shoot-through currents.
The demo application is composed of two sections :
Initializes the driver and enables the click board.
void application_init ( void )
{
log_cfg_t log_cfg;
dcmotor8_cfg_t cfg;
// Logger initialization.
LOG_MAP_USB_UART( log_cfg );
log_cfg.level = LOG_LEVEL_DEBUG;
log_cfg.baud = 9600;
log_init( &logger, &log_cfg );
log_info( &logger, "---- Application Init ----" );
// Click initialization.
dcmotor8_cfg_setup( &cfg );
DCMOTOR8_MAP_MIKROBUS( cfg, MIKROBUS_1 );
dcmotor8_init( &dcmotor8, &cfg );
dcmotor8_enable ( &dcmotor8, DCMOTOR8_ENABLE );
dcmotor8_pwm_start( &dcmotor8 );
}
Demonstrates the use of DC Motor 8 click board by increasing and decreasing the motor speed.
void application_task ( void )
{
log_printf( &logger,"\r\nIncreasing the motor RPM...\r\n" );
for ( float duty_cycle = 0.1; duty_cycle <= 1.0; duty_cycle += 0.1 )
{
dcmotor8_set_duty_cycle ( &dcmotor8, duty_cycle );
log_printf( &logger," > " );
Delay_ms( 200 );
}
log_printf( &logger,"\r\nSlowing down...\r\n" );
for ( float duty_cycle = 1.0; duty_cycle > 0; duty_cycle -= 0.1 )
{
dcmotor8_set_duty_cycle ( &dcmotor8, duty_cycle );
log_printf( &logger," < " );
Delay_ms( 200 );
}
}
The full application code, and ready to use projects can be installed directly form compilers IDE(recommneded) or found on LibStock page or mikroE GitHub accaunt.
Other mikroE Libraries used in the example:
- MikroSDK.Board
- MikroSDK.Log
- Click.DcMotor8
Additional notes and informations
Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all Mikroelektronika compilers, or any other terminal application of your choice, can be used to read the message.