susannasiebert commented Apr 1, 2024

  • The junction_scores.best_spacers.tsv and junction_scores.tsv intermediate files are currently identical. We should write a file that summarizes all the passing junctions at that point in the run, including spacers.
  • The -k flag is not respected for each iteration and the tmp file for each are currently deleted
  • Ensure that a log file of the inputs for the whole run gets created and checked against
  • Update some wording for "increasing the acceptable junction binding score to allow more possible connections (-b parameter)". The parameter should be decreased. Also add more detail to explain how the -b parameter impacts this.
  • Update the wording "No valid path found. No valid junction between peptides:" to add more context.
  • Add some sort of success messages, if we find a path
  • Temperature Energy Accept Improve Elapsed Remaining is written to to stderr instead of stdout
  • Use the percentile cutoff, if provided.
@susannasiebert susannasiebert added this to the 4.2.0 milestone Apr 1, 2024
@susannasiebert susannasiebert modified the milestones: 4.3.0, 4.4.0 Aug 21, 2024