Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathBMP280.h
206 lines (177 loc) · 5.8 KB
/
BMP280.h
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
// based on https://github.com/AlekseySedyshev/BME280/tree/master/32F042_LCD_128x64_BME280
#ifndef __BMP280_H__
#define __BMP280_H__
#include "ch32v003fun.h"
#include <stdint.h>
#include <stdbool.h>
/**
* BMP280 or BME280 address is 0x77 if SDO pin is high, and is 0x76 if
* SDO pin is low.
*/
#define BMP280_I2C_ADDRESS_0 0x76
#define BMP280_I2C_ADDRESS_1 0x77
#define BME280_ADDRESS 0xEC //0xEE (0x76<<1) / (0x77<<1)
#define BMP280_CHIP_ID 0x58 /* BMP280 has chip-id 0x58 */
#define BME280_CHIP_ID 0x60 /* BME280 has chip-id 0x60 */
/**
* BMP280 registers
*/
#define BMP280_REG_TEMP_XLSB 0xFC /* bits: 7-4 */
#define BMP280_REG_TEMP_LSB 0xFB
#define BMP280_REG_TEMP_MSB 0xFA
#define BMP280_REG_TEMP (BMP280_REG_TEMP_MSB)
#define BMP280_REG_PRESS_XLSB 0xF9 /* bits: 7-4 */
#define BMP280_REG_PRESS_LSB 0xF8
#define BMP280_REG_PRESS_MSB 0xF7
#define BMP280_REG_PRESSURE (BMP280_REG_PRESS_MSB)
#define BMP280_REG_CONFIG 0xF5 /* bits: 7-5 t_sb; 4-2 filter; 0 spi3w_en */
#define BMP280_REG_CTRL 0xF4 /* bits: 7-5 osrs_t; 4-2 osrs_p; 1-0 mode */
#define BMP280_REG_STATUS 0xF3 /* bits: 3 measuring; 0 im_update */
#define BMP280_REG_CTRL_HUM 0xF2 /* bits: 2-0 osrs_h; */
#define BMP280_REG_RESET 0xE0
#define BMP280_REG_ID 0xD0
#define BMP280_REG_CALIB 0x88
#define BMP280_REG_HUM_CALIB 0x88
#define BMP280_RESET_VALUE 0xB6
/**
* Mode of BMP280 module operation.
* Forced - Measurement is initiated by user.
* Normal - Continues measurement.
*/
typedef enum { //BMP280_Mode
BMP280_MODE_SLEEP = 0,
BMP280_MODE_FORCED = 1,
BMP280_MODE_NORMAL = 3
} BMP280_Mode;
typedef enum { //BMP280_Filter
BMP280_FILTER_OFF = 0,
BMP280_FILTER_2 = 1,
BMP280_FILTER_4 = 2,
BMP280_FILTER_8 = 3,
BMP280_FILTER_16 = 4
} BMP280_Filter;
/**
* Pressure oversampling settings
*/
typedef enum { //BMP280_Oversampling
BMP280_SKIPPED = 0, /* no measurement */
BMP280_ULTRA_LOW_POWER = 1, /* oversampling x1 */
BMP280_LOW_POWER = 2, /* oversampling x2 */
BMP280_STANDARD = 3, /* oversampling x4 */
BMP280_HIGH_RES = 4, /* oversampling x8 */
BMP280_ULTRA_HIGH_RES = 5 /* oversampling x16 */
} BMP280_Oversampling;
/**
* Stand by time between measurements in normal mode
*/
typedef enum { //BMP280_StandbyTime
BMP280_STANDBY_05 = 0, /* stand by time 0.5ms */
BMP280_STANDBY_62 = 1, /* stand by time 62.5ms */
BMP280_STANDBY_125 = 2, /* stand by time 125ms */
BMP280_STANDBY_250 = 3, /* stand by time 250ms */
BMP280_STANDBY_500 = 4, /* stand by time 500ms */
BMP280_STANDBY_1000 = 5, /* stand by time 1s */
BMP280_STANDBY_2000 = 6, /* stand by time 2s BMP280, 10ms BME280 */
BMP280_STANDBY_4000 = 7, /* stand by time 4s BMP280, 20ms BME280 */
} BMP280_StandbyTime;
/**
* Configuration parameters for BMP280 module.
* Use function bmp280_init_default_params to use default configuration.
*/
typedef struct { //bmp280_params_t
BMP280_Mode mode;
BMP280_Filter filter;
BMP280_Oversampling oversampling_pressure;
BMP280_Oversampling oversampling_temperature;
BMP280_Oversampling oversampling_humidity;
BMP280_StandbyTime standby;
} bmp280_params_t;
typedef struct { //BMP280_HandleTypedef
uint16_t dig_T1;
int16_t dig_T2;
int16_t dig_T3;
uint16_t dig_P1;
int16_t dig_P2;
int16_t dig_P3;
int16_t dig_P4;
int16_t dig_P5;
int16_t dig_P6;
int16_t dig_P7;
int16_t dig_P8;
int16_t dig_P9;
/* Humidity compensation for BME280 */
uint8_t dig_H1;
int16_t dig_H2;
uint8_t dig_H3;
int16_t dig_H4;
int16_t dig_H5;
int8_t dig_H6;
uint16_t addr;
bmp280_params_t params;
uint8_t id; /* Chip ID */
} BMP280_HandleTypedef;
class bmp280
{
public:
/**
* Initialize default parameters.
* Default configuration:
* mode: NORAML
* filter: OFF
* oversampling: x4
* standby time: 250ms
*/
void init_default_params();
/**
* Initialize BMP280 module, probes for the device, soft resets the device,
* reads the calibration constants, and configures the device using the supplied
* parameters. Returns true on success otherwise false.
*
* The I2C address is assumed to have been initialized in the dev, and
* may be either BMP280_I2C_ADDRESS_0 or BMP280_I2C_ADDRESS_1. If the I2C
* address is unknown then try initializing each in turn.
*
* This may be called again to soft reset the device and initialize it again.
*/
bool init();
/**
* Start measurement in forced mode.
* The module remains in forced mode after this call.
* Do not call this method in normal mode.
*/
void sleep();
void force_measurement();
/**
* Check if BMP280 is busy with measuring temperature/pressure.
* Return true if BMP280 is busy.
*/
bool is_measuring();
/**
* Read compensated temperature and pressure data:
*
* Temperature in degrees Celsius times 100.
*
* Pressure in Pascals in fixed point 24 bit integer 8 bit fraction format.
*
* Humidity is optional and only read for the BME280, in percent relative
* humidity as a fixed point 22 bit interger and 10 bit fraction format.
*/
void read_fixed();
int32_t getTemp();
uint32_t getPressurePa();
uint32_t getPressureMmHg();
uint32_t getHumidity();
void setI2CAddress(uint8_t);
private:
BMP280_HandleTypedef bmp280_handle;
void read_calibration_data();
void read_hum_calibration_data();
int32_t compensate_temperature(int32_t adc_T, int32_t *t_fine);
uint32_t compensate_pressure(int32_t adc_press, int32_t t_fine);
uint32_t compensate_humidity(int32_t adc_hum, int32_t t_fine);
uint32_t Pa_to_mmHg(uint32_t p_pa);
uint32_t pressure, humidity;
int32_t temperature;
uint8_t i2cAddress = BMP280_I2C_ADDRESS_0;
};
#endif // __BMP280_H__