-
-
Notifications
You must be signed in to change notification settings - Fork 126
4 Garage Doors (with multi channel device)
This simulation can be setup via the Homebridge/HOOBS UI, adding an entry in the 'Multi Channel Devices' section and setting the Device ID and the 'Show As' to '4 Garage Doors'.
Or if you prefer to edit the configuration directly, set the deviceId
and choose the showAs
option to "garage_four"
. For example:
"multiDevices": [
{
"deviceId": "10009553c8",
"deviceModel": "4ch",
"showAs": "garage_four",
"operationTime": 100
}
]
Your garage doors must be able to respond to this 'pulse' by starting to move up/down and then stopping with another 'pulse'. The plugin will send an initial request to turn the switch ON (and then be turned off by the eWeLink 'inching' setting) and the garage door will start moving. The plugin will then send another request to turn the switch ON (and then be turned off by the eWeLink 'inching' setting) after the operationTime
configuration setting to stop the garage door moving after the appropriate time.
The operationTime
is defined in deciseconds so time how long it takes to open/close the garages and multiply this by ten. If the garage door has a different UP and DOWN time then you can set operationTime
for the time UP and operationTimeDown
for the time DOWN.
Since it is impossible for the switch to report the correct position of the garage doors to Homebridge, the plugin relies on a cached state which changes each time the garage doors are opened/closed. There may be times when this becomes out of sync. If this happens, please make sure all the garage doors are fully closed, then remove the accessory from the Homebridge cache. The accessory will be added again with a CLOSED status which will match the garage doors.
An simple configuration example:
[
{
"deviceId": "10009553c8",
"type": "garage_four",
"operationTime": 105
}
]
- If using the Homebridge UI, it's easier to use the plugin settings screen to configure the simulation
- If using the HOOBS UI, copy and paste the example above into the 'Groups' box on the plugin settings screen
- If manually editing the config JSON, don't forget to change the first line to
"groups": [
Entry | Type | Required | Default | Explanation |
---|---|---|---|---|
deviceId |
string |
Yes | "" |
eWeLink Device ID. |
label |
string |
No | "" |
This setting has no effect except to be a helpful label for identifying which device this is when editing the configuration. |
type |
string |
Yes | "" |
In this case this must be set to "garage_four" . |
operationTime |
int |
Yes | 100 |
The time in deciseconds that the garage door takes to open/close. Must be 20 or more. |
operationTimeDown |
int |
No | 100 |
If the garage door has a different operation time for up and down, use this setting to specify the operation time DOWN (in deciseconds) and the other setting to specify the operation time UP. Must be 20 or more. |
ipAddress |
string |
No | "" |
You can manually set the IP address for this device if it cannot be discovered by the plugin. |
overrideLogging |
bool |
No | "default" |
Override global logging setting for this device. Can be default (follows global setting), standard for standard logging, debug for debug logging or disable to disable accessory logging. |