#!/bin/bash
#Device address map
ADD_LTC4100_READ=0x09
ADD_SMBUS_SYSTEM_HOST=0x10
ADD_SMART_BATTERY_CHARGER=0x12
ADD_SMART_BATTERY_SELECTOR=0x14
ADD_SMART_BATTERY=0x16
#ReadOnly LTC4100 Register
LTC4100_CHARGER_SPEC_INFO=0x11
LTC4100_CHARGER_STATUS=0x13
#WriteOnly LTC4100 Register
LTC4100_CHARGER_MODE=0x12
LTC4100_CHARGING_CURRENT=0x14
LTC4100_CHARGING_VOLTAGE=0x15
LTC4100_ALARM_WARNING=0x16
#Read/Write LTC4100 Register
LTC4100_LTCO=0x3C
# // SMBALERT will be de-asserted upon a successful read of ChargerStatus() pg.10 http://cds.linear.com/docs/en/datasheet/4100fc.pdf
# Serial.print("LTC4100_CHARGER_STATUS : ");Serial.print("\t");Serial.println(SMBReadWordCommand(ADD_SMART_BATTERY_CHARGER, LTC4100_CHARGER_STATUS));
# SMBWriteWordCommand(ADD_SMART_BATTERY_CHARGER, LTC4100_CHARGER_MODE, 8);
while true; do
# Voltage and Current mus be re-sended each 140-210 Sec to avoid timeout
# http://cds.linear.com/docs/en/datasheet/4100fc.pdf
# Pg.5 : Time Between Receiving Valid ChargingCurrent() and ChargingVoltage() Commands
# Pg.10 : The wake-up current is discontinued after tTIMEOUT if the SafetySignal is decoded
# as RES_UR or RES_C0LD, and the battery or host doesn't transmit charging commands
echo $(date) ' : Set charging voltage to ' $1 'mV and current to ' $2 'mA'
i2cset -y 1 $ADD_LTC4100_READ $LTC4100_CHARGING_VOLTAGE $1 w
# echo 'Set charging current to : ' $2 ' mA'
i2cset -y 1 $ADD_LTC4100_READ $LTC4100_CHARGING_CURRENT $2 w
sleep 20
done