Manually def. failure rate is lost when you switch to Operational f. r. #559

Open
grotskat opened this issue Aug 15, 2024 · 2 comments
Open
Assignees

Comments

@grotskat
Copy link
Collaborator

When I have the value M entered and I switch to O, the entered value M is deleted, i.e. when I switch back it is no value there.

image
image
image

@blcham
Copy link
Contributor

blcham commented Aug 15, 2024

This is expected behavior. We can discuss how to make it more intuitive.

@blcham
Copy link
Contributor

blcham commented Aug 16, 2024

Alternative solutions:

  • (x) leave the manually defined failure rate even after switch (we would need to have separate object for Manually defined failure rate which would be saved in FTAEvent context)
  • ( ) add confirmation that manually defined failure rate will be lost
  • ( ) show message that manually defined failure rate was lost
  • ...