Name Talker80-databus ;
PartNo 00 ;
Date 08.03.2020 ;
Revision 01 ;
Designer Michael Wessel / LambdaMikel ;
Company Home ;
Assembly None ;
Location ;
Device g22v10 ;
PIN 1 = SPEECH_WRITE ; // CLOCK !
PIN 13 = SPEECH_READ ; // OE FOR IN6D6, IN7D7
PIN 11 = IN6 ;
PIN 2 = IN7 ;
PIN 3 = D0 ;
PIN 4 = D1 ;
PIN 5 = D2 ;
PIN 6 = D3 ;
PIN 7 = D4 ;
PIN 8 = D5 ;
PIN 9 = D6 ;
PIN 10 = D7 ;
PIN 14 = IN6D6 ; // -> TRS databus Bit 6
PIN 15 = IN7D7 ; // -> TRS databus Bit 7 Speech Ready Signal
PIN 16 = Q0;
PIN 17 = Q1;
PIN 18 = Q2;
PIN 19 = Q3;
PIN 20 = Q4;
PIN 21 = Q5;
PIN 22 = Q6;
PIN 23 = Q7;
IN6D6 = IN6 ;
IN7D7 = IN7 ;
[Q0, Q1, Q2, Q3, Q4, Q5, Q6, Q7].d = [D0, D1, D2, D3, D4, D5, D6, D7];
[Q0, Q1, Q2, Q3, Q4, Q5, Q6, Q7].sp = SPEECH_WRITE;
// [Q0, Q1, Q2, Q3, Q4, Q5, Q6, Q7].ar = [D0, D1, D2, D3, D4, D5, D6, D7];
[IN6D6, IN7D7].oe = SPEECH_READ ; // Tristate for TRS databus