-
Notifications
You must be signed in to change notification settings - Fork 2
/
LM-SENSORS-MIB.txt
230 lines (196 loc) · 5.79 KB
/
LM-SENSORS-MIB.txt
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
LM-SENSORS-MIB DEFINITIONS ::= BEGIN
--
-- Derived from the original VEST-INTERNETT-MIB. Open issues:
--
-- (a) where to register this MIB?
-- (b) use not-accessible for diskIOIndex?
--
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Gauge32
FROM SNMPv2-SMI
DisplayString
FROM SNMPv2-TC
ucdExperimental
FROM UCD-SNMP-MIB;
lmSensorsMIB MODULE-IDENTITY
LAST-UPDATED "200011050000Z"
ORGANIZATION "AdamsNames Ltd"
CONTACT-INFO
"Primary Contact: M J Oldfield
email: m@mail.tc"
DESCRIPTION
"This MIB module defines objects for lm_sensor derived data."
REVISION "200011050000Z"
DESCRIPTION
"Derived from DISKIO-MIB ex UCD."
::= { lmSensors 1 }
lmSensors OBJECT IDENTIFIER ::= { ucdExperimental 16 }
--
lmTempSensorsTable OBJECT-TYPE
SYNTAX SEQUENCE OF LMTempSensorsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of temperature sensors and their values."
::= { lmSensors 2 }
lmTempSensorsEntry OBJECT-TYPE
SYNTAX LMTempSensorsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing a device and its statistics."
INDEX { lmTempSensorsIndex }
::= { lmTempSensorsTable 1 }
LMTempSensorsEntry ::= SEQUENCE {
lmTempSensorsIndex Integer32,
lmTempSensorsDevice DisplayString,
lmTempSensorsValue Gauge32
}
lmTempSensorsIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reference index for each observed device."
::= { lmTempSensorsEntry 1 }
lmTempSensorsDevice OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the temperature sensor we are reading."
::= { lmTempSensorsEntry 2 }
lmTempSensorsValue OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The temperature of this sensor in mC."
::= { lmTempSensorsEntry 3 }
--
lmFanSensorsTable OBJECT-TYPE
SYNTAX SEQUENCE OF LMFanSensorsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of fan sensors and their values."
::= { lmSensors 3 }
lmFanSensorsEntry OBJECT-TYPE
SYNTAX LMFanSensorsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing a device and its statistics."
INDEX { lmFanSensorsIndex }
::= { lmFanSensorsTable 1 }
LMFanSensorsEntry ::= SEQUENCE {
lmFanSensorsIndex Integer32,
lmFanSensorsDevice DisplayString,
lmFanSensorsValue Gauge32
}
lmFanSensorsIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reference index for each observed device."
::= { lmFanSensorsEntry 1 }
lmFanSensorsDevice OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the fan sensor we are reading."
::= { lmFanSensorsEntry 2 }
lmFanSensorsValue OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The rotation speed of the fan in RPM."
::= { lmFanSensorsEntry 3 }
--
lmVoltSensorsTable OBJECT-TYPE
SYNTAX SEQUENCE OF LMVoltSensorsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of voltage sensors and their values."
::= { lmSensors 4 }
lmVoltSensorsEntry OBJECT-TYPE
SYNTAX LMVoltSensorsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing a device and its statistics."
INDEX { lmVoltSensorsIndex }
::= { lmVoltSensorsTable 1 }
LMVoltSensorsEntry ::= SEQUENCE {
lmVoltSensorsIndex Integer32,
lmVoltSensorsDevice DisplayString,
lmVoltSensorsValue Gauge32
}
lmVoltSensorsIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reference index for each observed device."
::= { lmVoltSensorsEntry 1 }
lmVoltSensorsDevice OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the device we are reading."
::= { lmVoltSensorsEntry 2 }
lmVoltSensorsValue OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The voltage in mV."
::= { lmVoltSensorsEntry 3 }
--
lmMiscSensorsTable OBJECT-TYPE
SYNTAX SEQUENCE OF LMMiscSensorsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of miscellaneous sensor devices and their values."
::= { lmSensors 5 }
lmMiscSensorsEntry OBJECT-TYPE
SYNTAX LMMiscSensorsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing a device and its statistics."
INDEX { lmMiscSensorsIndex }
::= { lmMiscSensorsTable 1 }
LMMiscSensorsEntry ::= SEQUENCE {
lmMiscSensorsIndex Integer32,
lmMiscSensorsDevice DisplayString,
lmMiscSensorsValue Gauge32
}
lmMiscSensorsIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reference index for each observed device."
::= { lmMiscSensorsEntry 1 }
lmMiscSensorsDevice OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the device we are reading."
::= { lmMiscSensorsEntry 2 }
lmMiscSensorsValue OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this sensor."
::= { lmMiscSensorsEntry 3 }
END