You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
I have encountered this problem in the case of a CuZr and a NiCoCr potential. The header says that the functions are tabulated at N points, but in fact there are N+1 points. The additional value might be a zero at the end. The EAM reader fails due to this extra value. Interestingly, this is not a problem for Lammps. Maybe the Lammps reader ends the line when enough values are read. Anyway, failure is expected. Perhaps one could first check how many values are in the table and then raise an exception if there are too few / too many.
No description provided.
The text was updated successfully, but these errors were encountered: