forked from open-iscsi/targetcli-fb
-
Notifications
You must be signed in to change notification settings - Fork 0
/
targetcli.8
469 lines (469 loc) · 15.6 KB
/
targetcli.8
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
.TH targetcli 8
.SH NAME
.B targetcli
\- administration shell for storage targets
.SH DESCRIPTION
.B targetcli
is a shell for viewing, editing, and saving the configuration of the
kernel's target subsystem, also known as LIO. It enables the
administrator to assign local storage resources backed by either
files, volumes, local SCSI devices, or ramdisk, and export them to
remote systems via network fabrics, such as iSCSI or FCoE.
.P
The configuration layout is tree-based, similar to a filesystem, and
is navigated in a similar manner.
.SH USAGE
.B targetcli
.P
.B targetcli [cmd]
.P
Invoke
.B targetcli
as root to enter the configuration shell, or follow with a command to
execute but do not enter the shell. Use
.B ls
to list nodes below the current path. Moving around the tree is
accomplished by the
.B cd
command, or by entering the new location directly. Objects are created
using
.BR create ,
removed using
.BR delete .
Use
.B "help <cmd>"
for additional usage information. Tab-completion is available for
commands and command arguments.
.P
Configuration changes in targetcli are made immediately to the
underlying kernel target configuration. Settings will not be retained
across reboot unless
.B saveconfig
is either explicitly called, or implicitly by exiting the shell with
the global preference
.B auto_save_on_exit
set to
.BR true ,
the default.
.P
.SH QUICKSTART
To create an iSCSI target and share a file-backed LUN without any auth checks:
.P
$ sudo targetcli
.br
/> backstores/fileio create test /tmp/test.img 100m
.br
/> iscsi/ create iqn.2006-04.com.example:test-target
.br
/> cd iscsi/iqn.2006-04.com.example:test-target/tpg1/
.br
tpg1/> luns/ create /backstores/fileio/test
.br
tpg1/> set attribute generate_node_acls=1
.br
tpg1/> exit
.P
Although by default targetcli saves the running configuration upon
exit, a distribution-specific service must be enabled to restore the
saved configuration on reboot. See distribution documentation for
specifics, but for example:
.P
$ sudo systemctl enable target.service
.P
See
.B EXAMPLES
below for more detailed information on commands and using the shell.
.SH BACKSTORES
.B Backstores
are different kinds of local storage resources that the kernel target
uses to "back" the SCSI devices it exports. The mappings to local
storage resources that each backstore creates are called
.BR "storage objects" .
.SS FILEIO
Allows files to be treated as disk images. When storage objects of
this type are created, they can support either write-back or
write-thru operation. Using write-back enables the local filesystem
cache, which will improve performance but increase the risk of data
loss. It is also possible to use fileio with local block device files,
if buffered operation is needed.
.P
Fileio also supports using an existing file, or creating a new
file. New files are sparsely allocated by default.
.SS BLOCK
Allows a local disk block device to be shared.
.SS PSCSI
Allows a local SCSI device of any type to be shared. It is generally
advised to prefer the block backstore if sharing a block SCSI device
is desired.
.SS RAMDISK
Allows kernel memory to be shared as a block SCSI device. Since memory
is volatile, the contents of the ramdisk will be lost if the system
restarts, and this backstore is best used for testing only.
.P
It also supports "nullio" mode, which is not backed by any storage. It
discards all writes, and returns all-zeroes for reads.
.SS USERSPACE-BACKED
Backstores starting with "user:" are not supported in the kernel, but
rely on a userspace process to handle requests. See
.BR tcmu-runner (8)
for more information on creating backstores of this type.
.SH TARGETS
.B Targets
are instances of a
.BR fabric ,
which adapts the kernel target to a specific transport protocol such
as iSCSI, Fibre Channel, or SBP-2. Creating a target in targetcli
enables that target to be configured. The name of the target, its WWN
(world wide name), may link the configuration to a specific hardware
endpoint, like SRP for example, or it may not, like iSCSI.
.P
Aside from "backstores", all other top-level configuration nodes in
targetcli are fabrics that may have targets created for them. Fabrics
that require hardware are only listed if the hardware is present and
configured properly.
.SS CREATING A TARGET
Use the
.B create
command within a fabric's node to create a target. If the fabric's
targets are tied to hardware then targetcli will constrain the WWN to
available hardware WWNs. These can be shown via tab-completion. If the
fabric is not tied to hardware, such as iSCSI, then targetcli will
either auto-generate a WWN if none is given, or check that the given
WWN has the correct format. All WWNs are prefaced by their type, such
as "iqn", "naa", or "ib", and may be given with or without colons.
.P
iSCSI supports multiple WWN formats: iqn, naa, and eui. Other fabrics
support single formats only.
.SH CONFIGURING A TARGET
Not all fabrics have the same capabilities. Targets on different
fabrics will have different configuration node layouts. iSCSI has the
most to configure; other fabrics present subsets of iSCSI's feature
set.
.SH CONFIGURING ISCSI
iSCSI has the most options for configuration.
.SS TPGS
TPGs (Target Portal Groups) allow the iSCSI to support multiple
complete configurations within one target. This is useful for complex
quality-of-service configurations. targetcli will automatically create
one TPG when the target is created, and almost all setups only need
one.
.SS PORTALS
An iSCSI target may be reached via multiple IP addresses and
ports. These addr:port pairs are called
.BR portals .
Both IPv4 and IPv6 addresses are supported.
.P
When a target is created, targetcli automatically creates a default
portal listening on all IPv4 addresses (shown as 0.0.0.0) on port 3260.
If a different configuration is needed, the default portal can be
removed and portals configured as desired.
.P
If the hardware supports it,
.B iSER
(iSCSI Extensions for RDMA) may be enabled via the
.B enable_iser
command within each portal's node. Or, if the hardware supports it,
hardware offload may be enabled via the
.B enable_offload
command within each portal's node.
.SS LUNS
The kernel target exports SCSI Logical Units, also called
.BR LUNs .
This section links the previously-defined storage objects with the
target, and defines which number (the Logical Unit Number) the device
will use. Note that if ACLs are being used, a
.B "lun mapping"
must be created under the ACL that refers back to the TPG LUN.
.SS ACLS
ACLs (Access Control Lists) allow different configuration, depending
on the initiator that is connecting to the target. This includes both
per-initiator authentication settings as well as per-initiator LUN
mappings.
.P
.B "create <wwn>"
in the
.B acls
node creates an ACL for an initiator, and
.B create
within the ACL creates a LUN mapping. (This can either refer to the
TPG LUN, or to the storage object, in which case the TPG LUN will be
configured as well.) Global setting
.B auto_add_mapped_luns
affects this, see below.
.SS AUTHENTICATION
iSCSI supports authentication via the CHAP protocol, which uses a
username and password. The initiator may be required to supply valid
credentials to the target, and the target may also be required to
supply credentials back to the initiator. The latter is referred to as
.BR "mutual authentication" .
.P
Furthermore, authentication credentials may be different for each
session phase (Discovery or Normal), and authentication in a Normal
session may be set at the TPG level, or per-ACL.
.P
.B Discovery Authentication
.br
iSCSI Discovery sessions allow the initiator to connect to a portal
and discover targets with the SendTargets command, but not access
them. The four parameters
.BR userid ,
.BR password ,
.BR mutual_userid ", and"
.B mutual_password
are configured via
.B "set discovery_auth"
command within the top-level iscsi configuration node. 1-way
authentication is enabled if userid and password are both set, and
mutual authentication is enabled if all four are set. Authentication
is disabled by unsetting the parameters.
.P
.B Normal Authentication
.br
Similarly, the four parameters
.BR userid ,
.BR password ,
.BR mutual_userid ", and"
.B mutual_password
are configured via
.B "set auth"
command within the TPG node and ACL nodes. However, LIO only uses one
or the other, depending on the TPG's
.B generate_node_acls
attribute setting. If generate_node_acls is 1, the TPG-wide settings
will be used. If generate_node_acls is 0, then the user-created ACLs'
settings will be used.
.P
Enable generate_node_acls with
.B set attribute generate_node_acls=1
within the TPG node. This can be thought of as "ignore ACLs mode" --
both authentication and LUN mapping will then use the TPG settings.
.P
.B No Authentication
.br
Authentication is disabled by clearing the TPG "authentication"
attribute:
.BR "set attribute authentication=0" .
Although initiator names are trivially forgeable, generate_node_acls
still works here to either ignore user-defined ACLs and allow all, or
check that an ACL exists for the connecting initiator.
.SH CONFIGURING FIBRE CHANNEL (QLA2XXX)
Operation as a target requires that
.B /sys/module/qla2xxx/parameters/qlini_mode
report "disabled". This may require passing the
.B qlini_mode=disabled
parameter to the qla2xxx module when it loads.
.SH CONFIGURING FIBRE CHANNEL OVER ETHERNET (TCM_FC)
Ensure
.B "fcoeadm -i"
shows a working endpoint.
.SH CONFIGURING SRP
SRP (SCSI RDMA Protocol) requires that RDMA-capable hardware is
present. It uses "ib" WWNs.
.SH CONFIGURING LOOPBACK
Storage objects may be re-exported as local SCSI devices with this
fabric.
.SH CONFIGURING OTHER FABRICS
Other fabrics may be present. They are for specialized uses. Use at
your own risk.
.SH EXAMPLES
.SS DEFINING A STORAGE OBJECT WITHIN A BACKSTORE
.B backstores/fileio create disk1 /disks/disk1.img 140M
.br
Creates a storage object named
.I disk1
with the given path and size.
.B targetcli
supports common size abbreviations like 'M', 'G', and 'T'.
.P
.SS EXPORTING A STORAGE OBJECT VIA ISCSI
.B iscsi/ create
.br
Creates an iSCSI target with a default WWN. It will also create an
initial target portal group called
.IR tpg1 .
.P
.B iqn.2003-01.org.linux-iscsi.test2.x8664:sn123456789012/tpg1/
.br
An example of changing to the configuration node for the given
target's first target portal group (TPG). This is equivalent to giving
the command prefixed by "cd". (Although more can be useful for certain
setups, most configurations have a single TPG per target. In this
case, configuring the TPG is equivalent to configuring the overall
target.)
.P
.B portals/ create
.br
Add a portal, i.e. an IP address and TCP port via which the target can
be contacted by initiators. Only required if the default 0.0.0.0:3260
portal is not present.
.P
.B luns/ create /backstores/fileio/disk1
.br
Create a new LUN in the TPG, attached to the storage object that has
previously been defined. The storage object now shows up under the
/backstores configuration node as activated.
.P
.B acls/ create iqn.1994-05.com.redhat:4321576890
.br
Creates an ACL (access control list) entry for the given iSCSI
initiator.
.P
.B acls/iqn.1994-05.com.redhat:4321576890 create 2 0
.br
Gives the initiator access to the first exported LUN (lun0), which the
initiator will see as lun2. The default is to give the initiator
read/write access; if read-only access was desired, an additional "1"
argument would be added to enable write-protect. (Note: if global
setting
.B auto_add_mapped_luns
is true, this step is not necessary.)
.SS EXPORTING A STORAGE OBJECT VIA FCOE
.B tcm_fc/ create 20:00:00:19:99:a8:34:bc
.br
Create an FCoE target with the given WWN.
.B targetcli
can tab-complete the WWN based on registered FCoE interfaces. If none
are found, verify that they are properly configured and are shown in
the output of
.BR "fcoeadm -i" .
.P
.B tcm_fc/20:00:00:19:99:a8:34:bc/
.br
If
.B auto_cd_after_create
is set to false, change to the configuration node for the given
target, equivalent to giving the command prefixed by
.BR cd .
.P
.B luns/ create /backstores/fileio/disk1
.br
Create a new LUN for the interface, attached to a previously defined
storage object. The storage object now shows up under the /backstores
configuration node as
.BR activated .
.P
.B acls/ create 00:99:88:77:66:55:44:33
.br
Create an ACL (access control list), for defining the resources each
initiator may access. The default behavior is to auto-map existing
LUNs to the ACL; see help for more information.
.P
The LUN should now be accessible via FCoE.
.SH OTHER COMMANDS
.B saveconfig
.br
Save the current configuration settings to a file, from which settings
will be restored if the system is rebooted. By default, this will save
the configuration to
.IR /etc/target/saveconfig.json .
.P
This command is executed from the configuration root node.
.P
.B restoreconfig
.br
Restore target configuration from a file, the default is the file
listed under
.BR saveconfig .
This will fail if there is already an established config, unless the
.I clear_existing
option is set to
.IR true .
.P
This command is executed from the configuration root node.
.P
.B clearconfig
.br
Clears the entire current local configuration. The parameter
.I confirm=true
must also be given, as a precaution.
.P
This command is executed from the configuration root node.
.P
.B sessions [ list | detail ] [sid]
.br
Lists the current open sessions or a specific session, with or without
details.
.P
This command is executed from the configuration root node.
.P
.B exit
.br
Leave the configuration shell.
.SH SETTINGS GROUPS
Settings are broken into groups. Individual settings are accessed by
.B "get <group> <setting>"
and
.BR "set <group> <setting>=<value>" ,
and the settings of an entire group may be displayed by
.BR "get <group>" .
All except for
.I global
are associated with a particular configuration node.
.SS GLOBAL
Shell-related user-specific settings are in
.IR global ,
and are visible from all configuration nodes. They are mostly shell
display options, but some starting with
.B auto_
affect shell behavior and may merit customization. These include
.BR auto_save_on_exit ,
which controls if exiting targetcli saves the configuration;
.BR auto_add_mapped_luns ,
to automatically add existing LUNs to new ACLs, and new LUNS to
existing ACLs; and
.BR auto_cd_after_create ,
to change working path to newly-created nodes. Global settings
are user-specific and are saved to ~/.targetcli/ upon exit, unlike
other groups, which are system-wide and kept in
.BR /etc/target/saveconfig.json .
.SS BACKSTORE-SPECIFIC
.B attribute
.br
/backstore/<type>/<name> configuration node. Contains values relating
to the backstore and storage object.
.P
.SS ISCSI-SPECIFIC
.B discovery_auth
.br
/iscsi configuration node. Set the normal and mutual authentication
userid and password for discovery sessions, as well as enabling or
disabling it. By default it is disabled -- no authentication is
required for discovery.
.P
.B parameter
.br
/iscsi/<target_iqn>/tpgX configuration node. ISCSI-specific parameters
such as
.IR AuthMethod ,
.IR MaxBurstLength ,
.IR IFMarker ,
.IR DataDigest ,
and similar.
.P
.B attribute
.br
/iscsi/<target_iqn>/tpgX configuration node. Contains
implementation-specific settings for the TPG, such as
.BR authentication ,
to enforce or disable authentication for the full-feature phase
(i.e. non-discovery).
.P
.B auth
.br
/iscsi/<target_iqn>/tpgX/acls/<initiator_iqn> configuration node. Set
the userid and password for full-feature phase for this ACL.
.SH FILES
.B /etc/target/saveconfig.json
.br
.B /etc/target/backup/*
.SH SEE ALSO
.BR targetctl (8),
.BR tcmu-runner (8)
.SH AUTHOR
Written by Jerome Martin <jxm@risingtidesystems.com>.
.br
Man page written by Andy Grover <agrover@redhat.com>.
.SH REPORTING BUGS
Report bugs via <targetcli-fb-devel@lists.fedorahosted.org>
.br
or <https://github.com/open-iscsi/targetcli-fb/issues>